Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#452319 Information View DocsDoc View GISGIS
Sample Site ID452319
FacilityTypeOGProj Number
CountyJACKSON - 057LocationNWNW 16 7N80W
Elevation8127Lat/Long40.58415/-106.38733
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-057-06603Well Name:Janet 0780 1-16H21
Well Status:PROperator Name:FULCRUM ENERGY OPERATING LLC
Location:NWNW  16 7N  80W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   645673     Sample Date:  12/21/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 645673    Dolan Integration Group ID: DIG-030581
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS973BTU/cuft
SOPBUTANE0.171MOL %0.005
SOPC6+ (hexanes +)0.142MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-53.6per mil
SOPDELTA 13C C2-36.5per mil
SOPDELTA 13C C3-31.8per mil
SOPDELTA 13C iC4-32.5per mil
SOPDelta 13C iC5-27.9per mil
SOPDELTA 13C nC4-30.1per mil
SOPDelta 13C nC5-30.1per mil
SOPDELTA D C1-292per mil
SOPETHANE3.92MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.038MOL %0.005
SOPHYDROGEN5.817MOL %0.005
SOPISOBUTANE0.063MOL %0.005
SOPISOPENTANE0.057MOL %0.005
SOPMETHANE79.171MOL %0.005
SOPNITROGEN (N2)9.174MOL %0.005
SOPOXYGEN + ARGON0.305MOL %0.005
SOPPENTANE0.114MOL %0.005
SOPPROPANE1.029MOL %0.005
SOPSPECIFIC GRAVITY0.637No Unit

 Sample ID:   645674     Sample Date:  12/21/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 645674    Dolan Integration Group ID: DIG-030582
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1238BTU/cuft
SOPBUTANE2.273MOL %0.005
SOPC6+ (hexanes +)0.041MOL %0.005
SOPCARBON DIOXIDE2.014MOL %0.005
SOPDELTA 13C C1-53.9per mil
SOPDELTA 13C C2-37.2per mil
SOPDELTA 13C C3-32per mil
SOPDELTA 13C CO2-2.5per mil
SOPDelta 13C iC5-28.2per mil
SOPDELTA 13C nC4-31.1per mil
SOPDelta 13C nC5-30.4per mil
SOPDELTA D C1-288per mil
SOPETHANE8.449MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.09MOL %0.005
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.611MOL %0.005
SOPISOPENTANE0.629MOL %0.005
SOPMETHANE77.978MOL %0.005
SOPNITROGEN (N2)1.328MOL %0.005
SOPOXYGEN + ARGON0.009MOL %0.005
SOPPENTANE0.869MOL %0.005
SOPPROPANE5.709MOL %0.005
SOPSPECIFIC GRAVITY0.747No Unit

 Sample ID:   645968     Sample Date:  12/14/2022     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 645968    SPL ID: 22120136-012A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.0006MOL %
GPA 2286BENZENE0.0153MOL %
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1321BTU/cuft
GPA 2286BUTANE2.8641MOL %
GPA 2286C11 (mixed isomers)MOL %
GPA 2286C12 (mixed isomers)MOL %
GPA 2286C13 (mixed isomers)MOL %
GPA 2286CARBON DIOXIDE2.6837MOL %
GPA 2286CYCLOHEXANE0.0301MOL %
GPA 2286Decane0.0006MOL %
GPA 2286Decanes (mixed isomers)MOL %
GPA 2286ETHENE10.7791MOL %
GPA 2286ETHYLBENZENE0.0012MOL %
GPA 2286Heptane0.01MOL %
GPA 2286ISOBUTANE0.8455MOL %
GPA 2286ISOPENTANE0.6188MOL %
GPA 2286METHANE72.9412MOL %
GPA 2286N-HEXANE0.1041MOL %
GPA 2286n-octane0.0036MOL %
GPA 2286NITROGEN (N2)0.6732MOL %
GPA 2286NONANE0.0005MOL %
GPA 2286Other Heptanes0.11MOL %
GPA 2286Other Hexanes0.2067MOL %
GPA 2286Other Nonanes0.002MOL %
GPA 2286Other Octanes0.0206MOL %
GPA 2286PENTANE0.7498MOL %
GPA 2286PROPANE7.3255MOL %
GPA 2286SPECIFIC GRAVITY0.8022RATIO_AIR
GPA 2286Tetradecanes +MOL %
GPA 2286TOLUENE0.0041MOL %
GPA 2286TOTAL XYLENES0.003MOL %

 Sample ID:   620258     Sample Date:  10/19/2020     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 620258    SPL ID: 20100219-020A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1257.2BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1279.5BTU/cuft dry
GPA 2261-13BUTANE2.2344MOL %
GPA 2261-13C6+ (hexanes +)0.4712MOL %
GPA 2261-13CARBON DIOXIDE2.5363MOL %
GPA 2261-13ETHANE9.9425MOL %
GPA 2261-13ISOBUTANE0.7148MOL %
GPA 2261-13ISOPENTANE0.4279MOL %
GPA 2261-13METHANE75.4185MOL %
GPA 2261-13NITROGEN (N2)0.7957MOL %
GPA 2261-13PENTANE0.2506MOL %
GPA 2261-13PROPANE6.9066MOL %
GPA 2261-13SPECIFIC GRAVITY0.7745Ratio

 Sample ID:   631426     Sample Date:  10/04/2021     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 631426    SPL ID: CO 04R0050
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS - SATURATED BASIS1259BTU/cuft
GPA 2261-13BRITISH THERMAL UNITS- DRY BASIS1281.3BTU/cuft dry
GPA 2261-13BUTANE2.1992MOL %
GPA 2261-13C6+ (hexanes +)0.5939MOL %
GPA 2261-13CARBON DIOXIDE2.3345MOL %
GPA 2261-13ETHANE9.7166MOL %
GPA 2261-13ISOBUTANE0.5948MOL %
GPA 2261-13ISOPENTANE0.4817MOL %
GPA 2261-13METHANE77.1414MOL %
GPA 2261-13NITROGEN (N2)0.6126MOL %
GPA 2261-13PENTANE0.558MOL %
GPA 2261-13PROPANE5.1161MOL %
GPA 2261-13SPECIFIC GRAVITY0.771Ratio

 Sample ID:   602326     Sample Date:  08/28/2018     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  SPL

Sample Results for Sample # 602326    SPL ID: 18090001-004A
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.002MOL %0.001
GPA 2286BENZENE0.027MOL %0.001
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1427.7BTU/cuft
GPA 2286BUTANE3.39MOL %0.001
GPA 2286C11 (mixed isomers)0.002MOL %0.001
GPA 2286C12 (mixed isomers)0MOL %0.001
GPA 2286C13 (mixed isomers)0MOL %0.001
GPA 2286CARBON DIOXIDE1.582MOL %0.001
GPA 2286CYCLOHEXANE0.068MOL %0.001
GPA 2286Decane0.001MOL %0.001
GPA 2286Decanes (mixed isomers)0.011MOL %0.001
GPA 2286ETHANE12.189MOL %0.001
GPA 2286ETHYLBENZENE0.003MOL %0.001
GPA 2286HEPTANES, MIXED ISOMERS0.056MOL %0.001
GPA 2286ISOBUTANE1.064MOL %0.001
GPA 2286ISOPENTANE0.725MOL %0.001
GPA 2286METHANE68.909MOL %0.001
GPA 2286N-HEXANE0.199MOL %0.001
GPA 2286n-octane0.015MOL %0.001
GPA 2286NITROGEN (N2)0.608MOL %0.001
GPA 2286NONANE0.005MOL %0.001
GPA 2286Other Heptanes0.262MOL %0.001
GPA 2286Other Hexanes0.318MOL %0.001
GPA 2286Other Nonanes0.036MOL %0.001
GPA 2286Other Octanes0.13MOL %0.001
GPA 2286PENTANE0.837MOL %0.001
GPA 2286PROPANE9.531MOL %0.001
GPA 2286SPECIFIC GRAVITY0.8526RATIO_AIR
GPA 2286Tetradecanes +0MOL %0.001
GPA 2286TOLUENE0.02MOL %0.001
GPA 2286TOTAL XYLENES0.01MOL %0.001

 Sample ID:   602307     Sample Date:  08/02/2018     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  Paragon Automation

Sample Results for Sample # 602307    Paragon Automation ID: Janet 1-16
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 2261-13BRITISH THERMAL UNITS1540BTU/cuft
GPA 2261-13BUTANE4.74MOL %PRSNT
GPA 2261-13CARBON DIOXIDE1.65MOL %PRSNT
GPA 2261-13ETHANE12.71MOL %PRSNT
GPA 2261-13HEPTANES, MIXED ISOMERS0.624MOL %PRSNT
GPA 2261-13ISOBUTANE1.27MOL %PRSNT
GPA 2261-13ISOPENTANE1.02MOL %PRSNT
GPA 2261-13METHANE64.18MOL %PRSNT
GPA 2261-13N-HEXANE0.83MOL %PRSNT
GPA 2261-13n-octane0.245MOL %PRSNT
GPA 2261-13NITROGEN (N2)0.51MOL %PRSNT
GPA 2261-13NONANE0.02MOL %PRSNT
GPA 2261-13PENTANE1.38MOL %PRSNT
GPA 2261-13PROPANE10.82MOL %PRSNT
GPA 2261-13SPECIFIC GRAVITY0.925RATIO_AIR

 Sample ID:   667136     Sample Date:  07/23/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667136    American Mobile Research ID: CR-31
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.022MOL %
GPA 2286Avg Molecular Weight22.9233gm/mole
GPA 2286BENZENE0.033MOL %
GPA 2286BRITISH THERMAL UNITS - SATURATED BASIS1284.91BTU
GPA 2286BRITISH THERMAL UNITS- DRY BASIS1307.41BTU
GPA 2286BUTANE2.504MOL %
GPA 2286CARBON DIOXIDE2.644MOL %
GPA 2286COMPRESSIBILITY0.995801No Unit
GPA 2286CYCLOHEXANE0.068MOL %
GPA 2286CYCLOPENTANE0.03MOL %
GPA 2286DECANES +0.002MOL %
GPA 2286ETHENE9.668MOL %
GPA 2286ETHYLBENZENE0.001MOL %
GPA 2286HEPTANES, MIXED ISOMERS0.195MOL %
GPA 2286HYDROGEN SULFIDE0MOL %
GPA 2286ISOBUTANE0.68MOL %
GPA 2286ISOPENTANE0.618MOL %
GPA 2286METHANE74.845MOL %
GPA 2286METHYL CYCLOHEXANE0.035MOL %
GPA 2286N-HEXANE0.245MOL %
GPA 2286NITROGEN (N2)0.812MOL %
GPA 2286NONANE0.002MOL %
GPA 2286OCTANE, MIXED ISOMERS0.023MOL %
GPA 2286Other Hexanes0.37MOL %
GPA 2286PENTANE0.764MOL %
GPA 2286PROPANE6.421MOL %
GPA 2286Relative Density (air = 1)0.794813Ratio
GPA 2286SPECIFIC GRAVITY0.791476RATIO_AIR
GPA 2286TOLUENE0.012MOL %
GPA 2286Total non gas liquids GPM6.28267gal/MCF
GPA 2286TOTAL XYLENES0.006MOL %

 Sample ID:   667137     Sample Date:  07/23/2024     Matrix:  GAS     Collection Point:  SEP     Type:  SEP     Lab:  American Mobile Research

Sample Results for Sample # 667137    American Mobile Research ID: CR-32
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
ASTM D5504CARBON DISULFIDENDmg/L<
ASTM D5504HYDROGEN SULFIDE0.853mg/L
ASTM D5504Sulfur DioxideNDmg/L<

 Sample ID:   670603     Sample Date:  07/09/2025     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 670603    Dolan Integration Group ID: DIG-040397
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %0.694%
CALCcarbon preference index (Hunt)0.946Ratio
CALCcarbon preference index (Marzi)0.881Ratio
CALCcycloparaffins %1.169%
CALCisoparaffins % (branched)1.01%
CALCisoprenoids %13.2%
CALCn paraffin %49.77%
CALCnC17/(nC18+nC29) ratio0.982Ratio
CALCnC18/(nC18+nC19) ratio0.576Ratio
CALCphytane/nC18 ratio0.401Ratio
CALCpristane/nC17 ratio0.51Ratio
CALCpristane/phytane ratio1.579Ratio
CALCresolved unknowns %32.138%
G02G1,1,3-Trimethylcyclopentane1.002AREA COUNT1
G02G1,1,3-Trimethylcyclopentane86ppm10
G02G1,1-dimethylcyclopentane0.599AREA COUNT1
G02G1,1-dimethylcyclopentane51ppm10
G02G1,2,3-trimethylcyclopentane1.115AREA COUNT1
G02G1,2,3-trimethylcyclopentane95ppm10
G02G1,2,4-trimethylcyclopentane1.25AREA COUNT1
G02G1,2,4-trimethylcyclopentane107ppm10
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentaneNDAREA COUNT1ND
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANE0.313AREA COUNT1
G02G2,3-DIMETHYLBUTANE27ppm10
G02G2,3-dimethylpentane0.88AREA COUNT1
G02G2,3-dimethylpentane74ppm10
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-methylhexane1.972AREA COUNT1
G02G2-methylhexane165ppm10
G02G2-METHYLPENTANE2.983AREA COUNT1
G02G2-METHYLPENTANE249ppm10
G02G3,3-dimethylpentane0.88AREA COUNT1
G02G3,3-dimethylpentane74ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane2.594AREA COUNT1
G02G3-methylhexane217ppm10
G02G3-METHYLPENTANE1.996AREA COUNT1
G02G3-METHYLPENTANE167ppm10
G02GBENZENE1.152AREA COUNT1
G02GBENZENE88ppm10
G02GBUTANE8.123AREA COUNT1
G02GBUTANE670ppm10
G02Gcis-1,3-dimethylcyclopentane1.394AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane119ppm10
G02GCYCLOHEXANE3.794AREA COUNT1
G02GCYCLOHEXANE324ppm10
G02GCYCLOPENTANE1.038AREA COUNT1
G02GCYCLOPENTANE89ppm10
G02GDecane113.675AREA COUNT1
G02GDecane9577ppm10
G02GETHYLBENZENE3.247AREA COUNT1
G02GETHYLBENZENE269ppm10
G02GethylcyclopentaneNDAREA COUNT1ND
G02GethylcyclopentaneNDppm10ND
G02GHeptane6.622AREA COUNT1
G02GHeptane554ppm10
G02GHEXANES5.696AREA COUNT1
G02GHEXANES475ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANE1.769AREA COUNT1
G02GISOBUTANE141ppm10
G02GISOPENTANE4.184AREA COUNT1
G02GISOPENTANE338ppm10
G02Gisoprenoid C1016.996AREA COUNT1
G02Gisoprenoid C101432ppm10
G02Gisoprenoid C1138.723AREA COUNT1
G02Gisoprenoid C113266ppm10
G02Gisoprenoid C1368.706AREA COUNT1
G02Gisoprenoid C135806ppm10
G02Gisoprenoid C1460.137AREA COUNT1
G02Gisoprenoid C145087ppm10
G02Gisoprenoid C1556.319AREA COUNT1
G02Gisoprenoid C154769ppm10
G02Gisoprenoid C1674.529AREA COUNT1
G02Gisoprenoid C166311ppm10
G02Gisoprenoid C1860.297AREA COUNT1
G02Gisoprenoid C185111ppm10
G02Gisoprenoid C93.546AREA COUNT1
G02Gisoprenoid C9298ppm10
G02Gm-XYLENE8.43AREA COUNT1
G02Gm-XYLENE693ppm10
G02GMETHYL CYCLOHEXANE11.06AREA COUNT1
G02GMETHYL CYCLOHEXANE945ppm10
G02GMETHYLCYCLOPENTANE4.746AREA COUNT1
G02GMETHYLCYCLOPENTANE406ppm10
G02Gn-C11200.681AREA COUNT1
G02Gn-C1116924ppm10
G02Gn-C12200.553AREA COUNT1
G02Gn-C1216930ppm10
G02Gn-C13213.773AREA COUNT1
G02Gn-C1318065ppm10
G02Gn-C14180.137AREA COUNT1
G02Gn-C1415238ppm10
G02Gn-C15179.421AREA COUNT1
G02Gn-C1515192ppm10
G02Gn-C16145.682AREA COUNT1
G02Gn-C1612336ppm10
G02Gn-C17142.836AREA COUNT1
G02Gn-C1712107ppm10
G02Gn-C18115.107AREA COUNT1
G02Gn-C189756ppm10
G02Gn-C1984.822AREA COUNT1
G02Gn-C197189ppm10
G02Gn-C2072.521AREA COUNT1
G02Gn-C206152ppm10
G02Gn-C2147.16AREA COUNT1
G02Gn-C214002ppm10
G02Gn-C2234.262AREA COUNT1
G02Gn-C222908ppm10
G02Gn-C2320.392AREA COUNT1
G02Gn-C231732ppm10
G02Gn-C2414.199AREA COUNT1
G02Gn-C241206ppm10
G02Gn-C257.406AREA COUNT1
G02Gn-C25629ppm10
G02Gn-C267.096AREA COUNT1
G02Gn-C26603ppm10
G02Gn-C274.786AREA COUNT1
G02Gn-C27407ppm10
G02Gn-C283.715AREA COUNT1
G02Gn-C28316ppm10
G02Gn-C292.563AREA COUNT1
G02Gn-C29218ppm10
G02Gn-C303.52AREA COUNT1
G02Gn-C30299ppm10
G02Gn-C313.144AREA COUNT1
G02Gn-C31267ppm10
G02Gn-c322.166AREA COUNT1
G02Gn-c32184ppm10
G02Gn-C331.896AREA COUNT1
G02Gn-C33161ppm10
G02Gn-C341.153AREA COUNT1
G02Gn-C3498ppm10
G02Gn-C351.368AREA COUNT1
G02Gn-C35116ppm10
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane10.707AREA COUNT1
G02Gn-octane898ppm10
G02GNormal Alkane C937.212AREA COUNT1
G02GNormal Alkane C93129ppm10
G02Go-XYLENE6.52AREA COUNT1
G02Go-XYLENE546ppm10
G02Gp-XYLENE2.319AREA COUNT1
G02Gp-XYLENE198ppm10
G02GPENTANE6.547AREA COUNT1
G02GPENTANE544ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane46.169AREA COUNT1
G02Gphytane3917ppm10
G02Gpristane72.905AREA COUNT1
G02Gpristane6179ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE4.524AREA COUNT1
G02GTOLUENE361ppm10
G02Gtrans-1,2-dimethylcyclopentane2.569AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane220ppm10
G02Gtrans-1,3-dimethylcyclopentane1.311AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane112ppm10

 Sample ID:   669153     Sample Date:  06/30/2025     Matrix:  GAS     Collection Point:  SEP     Type:  PRDG     Lab:  Alliance Technical Group

Sample Results for Sample # 669153    Alliance Technical Group ID: Gregory - Janet 1-16
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
GPA 22862,2,4-Trimethylpentane0.0001MOL %0.001
GPA 2286BENZENE0.0096MOL %0.001
GPA 2286BUTANE1.7929MOL %0.02
GPA 2286CARBON DIOXIDE3.3429MOL %0.02
GPA 2286CYCLOHEXANE0.0193MOL %0.001
GPA 2286CYCLOPENTANE0.0394MOL %0.001
GPA 2286DECANES +0.0024MOL %0.001
GPA 2286ETHANE9.6426MOL %0.02
GPA 2286ETHYLBENZENE0.0002MOL %0.001
GPA 2286Heptane0.0562MOL %0.001
GPA 2286HYDROGEN SULFIDE0MOL %0.05
GPA 2286ISOBUTANE0.5699MOL %0.02
GPA 2286ISOPENTANE0.3421MOL %0.02
GPA 2286METHANE77.0501MOL %0.02
GPA 2286METHYL CYCLOHEXANE0.0153MOL %0.001
GPA 2286N-HEXANE0.0734MOL %0.001
GPA 2286NITROGEN (N2)0.7105MOL %0.02
GPA 2286NONANE0.0021MOL %0.001
GPA 2286OCTANE, MIXED ISOMERS0.0159MOL %0.001
GPA 2286Other Hexanes0.1458MOL %0.001
GPA 2286OXYGEN + ARGON0.0143MOL %0.02
GPA 2286PENTANE0.3986MOL %0.02
GPA 2286PROPANE5.7522MOL %0.04
GPA 2286TOLUENE0.0036MOL %0.001
GPA 2286TOTAL XYLENES0.0007MOL %0.001

 Sample ID:   659167     Sample Date:  04/16/2024     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 659167    Pace Analytical ID: L1727463-05
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E365.4PHOSPHORUS0.794mg/L0.1
E904.0228RADIUM27.5pCi/L0.663
RSK-175ETHANE3.08mg/L0.013
RSK-175ETHENENDmg/L0.013U
RSK-175METHANE8.74mg/L0.1
SM2320BBICARBONATE ALKALINITY as CACO3716mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L20U
SM2320BTOTAL ALKALINITY AS CACO3716mg/L20
SM2540CTOTAL DISSOLVED SOLIDS38200mg/L1000
SM2540DTOTAL SUSPENDED SOLIDS133mg/L10
SM4500-P-EORTHOPHOSPHATE0.181mg/L0.03T8
SM7500-RN-B226RADIUM101pCi/L0.144
SW6010BARIUM93.4mg/L0.125
SW6010BORON25.7mg/L5
SW6010CALCIUM580mg/L25
SW6010IRON247mg/L2.5
SW6010MAGNESIUM73.4mg/L25
SW6010MANGANESE3mg/L0.25
SW6010POTASSIUM60.2mg/L50
SW6010SELENIUMNDmg/L0.25U
SW6010SODIUM13900mg/L75
SW6010STRONTIUM103mg/L0.25
SW8015C10-C28 Diesel Range Organics44.5mg/L1
SW8015C28-C36 Motor Oil Range Organics30.7mg/L1
SW8015TVPH - Gasoline Range Organics54.3mg/L1
SW846 8260BBENZENE14.2mg/L0.5
SW846 8260BETHYLBENZENE0.285mg/L0.01
SW846 8260BNAPHTHALENE0.12mg/L0.05
SW846 8260BTOLUENE3mg/L0.5
SW846 8260BTOTAL XYLENES1.19mg/L0.03
SW9040PH, LAB6.59SUT8
SW9050SPECIFIC CONDUCTIVITY61800umhos/cm10
SW9056BROMIDE345mg/L100
SW9056CHLORIDE24500mg/L500
SW9056FLUORIDENDmg/L15U
SW9056NITRATENDmg/L10U
SW9056NITRITENDmg/L10U
SW9056SULFATENDmg/L500U

 Sample ID:   666481     Sample Date:  03/18/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 666481    Pace Analytical ID: L1837653-01
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E904.0228RADIUM30.7pCi/L0.505
SM7500-RN-B226RADIUM86.8pCi/L0.163

 Sample ID:   666482     Sample Date:  03/18/2025     Matrix:  WATER     Collection Point:  SEP     Type:  PRDW     Lab:  Pace Analytical

Sample Results for Sample # 666482    Pace Analytical ID: L1837642-01
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E365.4PHOSPHORUS0.306mg/L0.1
RSK-175ETHANE2.62mg/L0.013
RSK-175ETHENENDmg/L0.013U
RSK-175METHANE5.53mg/L0.01
SM2320BBICARBONATE ALKALINITY as CACO3418mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3NDmg/L20U
SM2320BTOTAL ALKALINITY AS CACO3418mg/L20
SM2540CTOTAL DISSOLVED SOLIDS41000mg/L1000
SM2540DTOTAL SUSPENDED SOLIDS56.3mg/L7.15
SM4500-P-EORTHOPHOSPHATE0.149mg/L0.03
SW6010BARIUM79.2mg/L0.025
SW6010BORON29.5mg/L1
SW6010CALCIUM897mg/L5
SW6010IRON109mg/L0.5
SW6010MAGNESIUM90.7mg/L5
SW6010MANGANESE1.47mg/L0.05
SW6010POTASSIUM66.1mg/L10
SW6010SELENIUMNDmg/L0.05U
SW6010SODIUM15700mg/L75
SW6010STRONTIUM130mg/L0.25
SW8015C10-C28 Diesel Range Organics47.6mg/L1
SW8015C28-C36 Motor Oil Range Organics29mg/L1
SW8015TVPH - Gasoline Range Organics36.7mg/L5
SW846 8260BBENZENE6.16mg/L0.05
SW846 8260BETHYLBENZENE0.218mg/L0.05
SW846 8260BNAPHTHALENENDmg/L0.25U
SW846 8260BTOLUENE2.25mg/L0.05
SW846 8260BTOTAL XYLENES1mg/L0.15
SW9040PH, LAB6.23SUT8
SW9050SPECIFIC CONDUCTIVITY66500umhos/cm10
SW9056BROMIDE306mg/L50
SW9056CHLORIDE24000mg/L500
SW9056FLUORIDENDmg/L7.5U
SW9056NITRATENDmg/L5U
SW9056NITRITENDmg/L5U
SW9056SULFATENDmg/L250U