Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#453349 Information View DocsDoc View GISGIS
Sample Site ID453349
FacilityTypeOGProj Number
CountyWELD - 123LocationSWNW 11 3N68W
Elevation4976Lat/Long40.24367/-104.977706
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-46043Well Name:Postle IC 09-302HC
Well Status:SIOperator Name:PDC ENERGY INC
Location:SWNW  11 3N  68W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   660804     Sample Date:  7/12/2024     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 660804    Dolan Integration Group ID: DIG-036204
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1369BTU/cuft
SOPBUTANE2.841MOL %0.005
SOPC6+ (hexanes +)0.605MOL %0.005
SOPCARBON DIOXIDE1.28MOL %0.005
SOPDELTA 13C C1-49.8per mil
SOPDELTA 13C C2-34.1per mil
SOPDELTA 13C C3-29.9per mil
SOPDELTA 13C CO22.1per mil
SOPDELTA 13C iC4-31.9per mil
SOPDelta 13C iC5-28.7per mil
SOPDELTA 13C nC4-28.5per mil
SOPDelta 13C nC5-28.5per mil
SOPDELTA D C1-268per mil
SOPETHANE13.948MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.157MOL %0.005
SOPISOBUTANE0.97MOL %0.005
SOPISOPENTANE0.769MOL %0.005
SOPMETHANE70.221MOL %0.005
SOPNITROGEN (N2)0.708MOL %0.005
SOPOXYGEN + ARGON0.052MOL %0.005
SOPPENTANE0.951MOL %0.005
SOPPROPANE7.496MOL %0.005
SOPSPECIFIC GRAVITY0.813No Unit

 Sample ID:   660803     Sample Date:  7/12/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 660803    Dolan Integration Group ID: DIG-036203
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS41BTU/cuft
SOPBUTANE0.116MOL %0.005
SOPC6+ (hexanes +)0.026MOL %0.005
SOPCARBON DIOXIDE0.085MOL %0.005
SOPDELTA 13C C1-50.9per mil
SOPDELTA 13C C2-34per mil
SOPDELTA 13C C3-30per mil
SOPDelta 13C iC5-28.4per mil
SOPDELTA 13C nC4-28.6per mil
SOPDelta 13C nC5-28.2per mil
SOPDELTA D C1-261per mil
SOPETHANE0.236MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN19.816MOL %0.005
SOPISOBUTANE0.036MOL %0.005
SOPISOPENTANE0.042MOL %0.005
SOPMETHANE1.37MOL %0.005
SOPNITROGEN (N2)65.479MOL %0.005
SOPOXYGEN + ARGON12.581MOL %0.005
SOPPENTANE0.049MOL %0.005
SOPPROPANE0.164MOL %0.005
SOPSPECIFIC GRAVITY0.988No Unit

 Sample ID:   624404     Sample Date:  4/15/2021     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ALS

Sample Results for Sample # 624404    ALS ID: 2104361-2
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM880mg/L10
E200.7MAGNESIUMNDmg/L10U
E200.7POTASSIUM5000mg/L100
E200.7SODIUM3300mg/L100

 Sample ID:   624403     Sample Date:  4/15/2021     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  ALS

Sample Results for Sample # 624403    ALS ID: 2104361-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM870mg/L10
E200.7MAGNESIUMNDmg/L10U
E200.7POTASSIUM4900mg/L100
E200.7SODIUM3300mg/L100
E300.0CHLORIDE10000mg/L200
E300.0SULFATE370mg/L200
RSK175ETHANE370ug/L12
RSK175METHANE950ug/L6
RSK175PROPANE400ug/L6
SM2320BBICARBONATE ALKALINITY as CACO3NDmg/L500U
SM2320BCARBONATE ALKALINITY AS CACO31400mg/L500
SM2320BTOTAL ALKALINITY AS CACO33800mg/L500
SM2540CTOTAL DISSOLVED SOLIDS8200mg/L2000
SW8015TEPH DIESEL RANGE ORGANICS240mg/L5.1
SW8015TVPH - Gasoline Range Organics90mg/L10
SW8260BENZENE100ug/L5
SW8260ETHYLBENZENE59ug/L5
SW8260M-+P-XYLENE210ug/L5
SW8260o-XYLENE120ug/L5
SW8260TOLUENE200ug/L5
SW8260TOTAL XYLENES330ug/L1

 Sample ID:   615352     Sample Date:  11/1/2019     Matrix:  LIQUID     Collection Point:  SEP     Type:  SEP     Lab:  --

Sample Results for Sample # 615352    -- ID: DIG-020883
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane32.458AREA COUNT1
G02G1,1,3-Trimethylcyclopentane2883ppm10
G02G1,1-dimethylcyclopentane30.11AREA COUNT1
G02G1,1-dimethylcyclopentane2674ppm10
G02G1,2,3-trimethylcyclopentane23.004AREA COUNT1
G02G1,2,3-trimethylcyclopentane2043ppm10
G02G1,2,4-trimethylcyclopentane29.324AREA COUNT1
G02G1,2,4-trimethylcyclopentane2605ppm10
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANE3.112AREA COUNT1
G02G2,2-DIMETHYLBUTANE270ppm10
G02G2,2-dimethylpentane4.265AREA COUNT1
G02G2,2-dimethylpentane371ppm10
G02G2,3-DIMETHYLBUTANE19.328AREA COUNT1
G02G2,3-DIMETHYLBUTANE1717ppm10
G02G2,3-dimethylpentane30.022AREA COUNT1
G02G2,3-dimethylpentane2613ppm10
G02G2,4-dimethylpentane15.568AREA COUNT1
G02G2,4-dimethylpentane1355ppm10
G02G2-METHYLPENTANE156.585AREA COUNT1
G02G2-METHYLPENTANE13589ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane95.17AREA COUNT1
G02G3-methylhexane8284ppm10
G02G3-METHYLPENTANE93.41AREA COUNT1
G02G3-METHYLPENTANE8106ppm10
G02GBENZENE46.745AREA COUNT1
G02GBENZENE3708ppm10
G02GBTX aromatics %4.737%
G02GBUTANE196.007AREA COUNT1
G02GBUTANE16801ppm10
G02Gcarbon preference index (Hunt)0.984Ratio
G02Gcarbon preference index (Marzi)0.992Ratio
G02Gcis-1,3-dimethylcyclopentane44.765AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane3976ppm10
G02GCYCLOHEXANE140.997AREA COUNT1
G02GCYCLOHEXANE12524ppm10
G02Gcycloparaffins %14.006%
G02GCYCLOPENTANE36.377AREA COUNT1
G02GCYCLOPENTANE3231ppm10
G02GDecane136.39AREA COUNT1
G02GDecane11945ppm10
G02GETHYLBENZENE17.855AREA COUNT1
G02GETHYLBENZENE1540ppm10
G02Gethylcyclopentane11.886AREA COUNT1
G02Gethylcyclopentane1056ppm10
G02GHEPTANES, MIXED ISOMERS262.203AREA COUNT1
G02GHEPTANES, MIXED ISOMERS22824ppm10
G02GHEXANES291.735AREA COUNT1
G02GHEXANES25317ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANE37.982AREA COUNT1
G02GISOBUTANE3148ppm10
G02Gisoparaffins % (branched)12.103%
G02GISOPENTANE186.794AREA COUNT1
G02GISOPENTANE15696ppm10
G02Gisoprenoid C1042.61AREA COUNT1
G02Gisoprenoid C103732ppm10
G02Gisoprenoid C1131.616AREA COUNT1
G02Gisoprenoid C112772ppm10
G02Gisoprenoid C1326.241AREA COUNT1
G02Gisoprenoid C132305ppm10
G02Gisoprenoid C1424.226AREA COUNT1
G02Gisoprenoid C142130ppm10
G02Gisoprenoid C1528.532AREA COUNT1
G02Gisoprenoid C152512ppm10
G02Gisoprenoid C1633.607AREA COUNT1
G02Gisoprenoid C162958ppm10
G02Gisoprenoid C1829.724AREA COUNT1
G02Gisoprenoid C182619ppm10
G02Gisoprenoid C930.529AREA COUNT1
G02Gisoprenoid C92668ppm10
G02Gisoprenoids %3.81%
G02Gm-XYLENE95.652AREA COUNT1
G02Gm-XYLENE8173ppm10
G02GMETHYL CYCLOHEXANE333.431AREA COUNT1
G02GMETHYL CYCLOHEXANE29617ppm10
G02GMETHYLCYCLOPENTANE163.809AREA COUNT1
G02GMETHYLCYCLOPENTANE14550ppm10
G02Gn paraffin %33.989%
G02Gn-C11128.189AREA COUNT1
G02Gn-C1111238ppm10
G02Gn-C12104.562AREA COUNT1
G02Gn-C129176ppm10
G02Gn-C13100.014AREA COUNT1
G02Gn-C138786ppm10
G02Gn-C1488.458AREA COUNT1
G02Gn-C147779ppm10
G02Gn-C1592.026AREA COUNT1
G02Gn-C158101ppm10
G02Gn-C1681.091AREA COUNT1
G02Gn-C167138ppm10
G02Gn-C1776.642AREA COUNT1
G02Gn-C176753ppm10
G02Gn-C1864.638AREA COUNT1
G02Gn-C185695ppm10
G02Gn-C1956.424AREA COUNT1
G02Gn-C194972ppm10
G02Gn-C2055.801AREA COUNT1
G02Gn-C204921ppm10
G02Gn-C2146.757AREA COUNT1
G02Gn-C214125ppm10
G02Gn-C2243.222AREA COUNT1
G02Gn-C223814ppm10
G02Gn-C2340.42AREA COUNT1
G02Gn-C233568ppm10
G02Gn-C2437.684AREA COUNT1
G02Gn-C243327ppm10
G02Gn-C2530.977AREA COUNT1
G02Gn-C252736ppm10
G02Gn-C2627.928AREA COUNT1
G02Gn-C262467ppm10
G02Gn-C2723.081AREA COUNT1
G02Gn-C272039ppm10
G02Gn-C2820.221AREA COUNT1
G02Gn-C281787ppm10
G02Gn-C2917.039AREA COUNT1
G02Gn-C291506ppm10
G02Gn-C3014.188AREA COUNT1
G02Gn-C301254ppm10
G02Gn-C3112.482AREA COUNT1
G02Gn-C311104ppm10
G02Gn-c3210.077AREA COUNT1
G02Gn-c32891ppm10
G02Gn-C339.136AREA COUNT1
G02Gn-C33808ppm10
G02Gn-C346.179AREA COUNT1
G02Gn-C34547ppm10
G02Gn-C353.451AREA COUNT1
G02Gn-C35305ppm10
G02Gn-C362.299AREA COUNT1
G02Gn-C36196ppm10
G02Gn-C371.749AREA COUNT1
G02Gn-C37149ppm10
G02Gn-C381.549AREA COUNT1
G02Gn-C38132ppm10
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane204.732AREA COUNT1
G02Gn-octane17858ppm10
G02GnC17/(nC18+nC29) ratio0.818Ratio
G02GnC18/(nC18+nC19) ratio0.534Ratio
G02GNormal Alkane C9191.927AREA COUNT1
G02GNormal Alkane C916775ppm10
G02Go-XYLENE48.802AREA COUNT1
G02Go-XYLENE4248ppm10
G02Gp-XYLENE32.003AREA COUNT1
G02Gp-XYLENE2843ppm10
G02GPENTANE301.767AREA COUNT1
G02GPENTANE26054ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane22.624AREA COUNT1
G02Gphytane1995ppm10
G02Gphytane/nC18 ratio0.35Ratio
G02Gpristane42.015AREA COUNT1
G02Gpristane3702ppm10
G02Gpristane/nC17 ratio0.548Ratio
G02Gpristane/phytane ratio1.857Ratio
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02Gresolved unknowns %27.643%
G02GTOLUENE146.501AREA COUNT1
G02GTOLUENE12167ppm10
G02Gtrans-1,2-dimethylcyclopentane71.033AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane6309ppm10
G02Gtrans-1,3-dimethylcyclopentane41.874AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane3719ppm10

 Sample ID:   615353     Sample Date:  11/1/2019     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  --

Sample Results for Sample # 615353    -- ID: DIG-020882
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-TrimethylcyclopentaneNDAREA COUNT1ND
G02G1,1,3-TrimethylcyclopentaneNDppm10ND
G02G1,1-dimethylcyclopentane0.439AREA COUNT1
G02G1,1-dimethylcyclopentane43ppm10
G02G1,2,3-trimethylcyclopentaneNDAREA COUNT1ND
G02G1,2,3-trimethylcyclopentaneNDppm10ND
G02G1,2,4-trimethylcyclopentane1.462AREA COUNT1
G02G1,2,4-trimethylcyclopentane142ppm10
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentaneNDAREA COUNT1ND
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,3-DIMETHYLBUTANENDppm10ND
G02G2,3-dimethylpentane0.487AREA COUNT1
G02G2,3-dimethylpentane46ppm10
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-METHYLPENTANE1.213AREA COUNT1
G02G2-METHYLPENTANE115ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane1.383AREA COUNT1
G02G3-methylhexane132ppm10
G02G3-METHYLPENTANE0.733AREA COUNT1
G02G3-METHYLPENTANE70ppm10
G02GBENZENE0.564AREA COUNT1
G02GBENZENE49ppm10
G02GBTX aromatics %0.447%
G02GBUTANE1.509AREA COUNT1
G02GBUTANE142ppm10
G02Gcarbon preference index (Hunt)0.943Ratio
G02Gcarbon preference index (Marzi)0.98Ratio
G02Gcis-1,3-dimethylcyclopentane0.586AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane57ppm10
G02GCYCLOHEXANE1.567AREA COUNT1
G02GCYCLOHEXANE152ppm10
G02Gcycloparaffins %0.531%
G02GCYCLOPENTANENDAREA COUNT1ND
G02GCYCLOPENTANENDppm10ND
G02GDecane89.125AREA COUNT1
G02GDecane8551ppm10
G02GETHYLBENZENE1.339AREA COUNT1
G02GETHYLBENZENE127ppm10
G02Gethylcyclopentane0.741AREA COUNT1
G02Gethylcyclopentane72ppm10
G02GHEPTANES, MIXED ISOMERS3.575AREA COUNT1
G02GHEPTANES, MIXED ISOMERS341ppm10
G02GHEXANES2.535AREA COUNT1
G02GHEXANES241ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANE0.341AREA COUNT1
G02GISOBUTANE31ppm10
G02Gisoparaffins % (branched)0.611%
G02GISOPENTANE1.28AREA COUNT1
G02GISOPENTANE118ppm10
G02Gisoprenoid C1018.689AREA COUNT1
G02Gisoprenoid C101793ppm10
G02Gisoprenoid C1131.448AREA COUNT1
G02Gisoprenoid C113020ppm10
G02Gisoprenoid C1349.434AREA COUNT1
G02Gisoprenoid C134757ppm10
G02Gisoprenoid C1442.542AREA COUNT1
G02Gisoprenoid C144098ppm10
G02Gisoprenoid C1541.225AREA COUNT1
G02Gisoprenoid C153975ppm10
G02Gisoprenoid C1659.759AREA COUNT1
G02Gisoprenoid C165762ppm10
G02Gisoprenoid C1853.025AREA COUNT1
G02Gisoprenoid C185118ppm10
G02Gisoprenoid C92.504AREA COUNT1
G02Gisoprenoid C9240ppm10
G02Gisoprenoids %7.66%
G02Gm-XYLENE8.006AREA COUNT1
G02Gm-XYLENE749ppm10
G02GMETHYL CYCLOHEXANE8.635AREA COUNT1
G02GMETHYL CYCLOHEXANE840ppm10
G02GMETHYLCYCLOPENTANE1.514AREA COUNT1
G02GMETHYLCYCLOPENTANE147ppm10
G02Gn paraffin %26.944%
G02Gn-C11148.269AREA COUNT1
G02Gn-C1114239ppm10
G02Gn-C12139.567AREA COUNT1
G02Gn-C1213417ppm10
G02Gn-C13146.334AREA COUNT1
G02Gn-C1314082ppm10
G02Gn-C14130.289AREA COUNT1
G02Gn-C1412550ppm10
G02Gn-C15132.179AREA COUNT1
G02Gn-C1512745ppm10
G02Gn-C16116.103AREA COUNT1
G02Gn-C1611195ppm10
G02Gn-C17119.611AREA COUNT1
G02Gn-C1711545ppm10
G02Gn-C1893.358AREA COUNT1
G02Gn-C189011ppm10
G02Gn-C1971.433AREA COUNT1
G02Gn-C196895ppm10
G02Gn-C2057.515AREA COUNT1
G02Gn-C205556ppm10
G02Gn-C2136.386AREA COUNT1
G02Gn-C213516ppm10
G02Gn-C2225.579AREA COUNT1
G02Gn-C222473ppm10
G02Gn-C2314.636AREA COUNT1
G02Gn-C231415ppm10
G02Gn-C2410.673AREA COUNT1
G02Gn-C241032ppm10
G02Gn-C253.984AREA COUNT1
G02Gn-C25385ppm10
G02Gn-C263.105AREA COUNT1
G02Gn-C26300ppm10
G02Gn-C271.908AREA COUNT1
G02Gn-C27185ppm10
G02Gn-C281.496AREA COUNT1
G02Gn-C28145ppm10
G02Gn-C291.192AREA COUNT1
G02Gn-C29115ppm10
G02Gn-C301.143AREA COUNT1
G02Gn-C30111ppm10
G02Gn-C311.074AREA COUNT1
G02Gn-C31104ppm10
G02Gn-c32NDAREA COUNT1ND
G02Gn-c32NDppm10ND
G02Gn-C33NDAREA COUNT1ND
G02Gn-C33NDppm10ND
G02Gn-C34NDAREA COUNT1ND
G02Gn-C34NDppm10ND
G02Gn-C35NDAREA COUNT1ND
G02Gn-C35NDppm10ND
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane6.999AREA COUNT1
G02Gn-octane669ppm10
G02GnC17/(nC18+nC29) ratio0.99Ratio
G02GnC18/(nC18+nC19) ratio0.567Ratio
G02GNormal Alkane C936.755AREA COUNT1
G02GNormal Alkane C93519ppm10
G02Go-XYLENE6.796AREA COUNT1
G02Go-XYLENE648ppm10
G02Gp-XYLENE2.759AREA COUNT1
G02Gp-XYLENE268ppm10
G02GPENTANE2.004AREA COUNT1
G02GPENTANE190ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane39.932AREA COUNT1
G02Gphytane3858ppm10
G02Gphytane/nC18 ratio0.428Ratio
G02Gpristane58.977AREA COUNT1
G02Gpristane5693ppm10
G02Gpristane/nC17 ratio0.493Ratio
G02Gpristane/phytane ratio1.477Ratio
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02Gresolved unknowns %61.478%
G02GTOLUENE3.727AREA COUNT1
G02GTOLUENE339ppm10
G02Gtrans-1,2-dimethylcyclopentane0.848AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane83ppm10
G02Gtrans-1,3-dimethylcyclopentane0.481AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane47ppm10

 Sample ID:   617128     Sample Date:  11/1/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 617128    Dolan Integration Group ID: DIG-020880
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1178BTU/cuft
SOPBUTANE1.01MOL %0.005
SOPC6+ (hexanes +)0.04MOL %0.005
SOPCARBON DIOXIDE0.6MOL %0.005
SOPDELTA 13C C1-50.2per mil
SOPDELTA 13C C2-33.7per mil
SOPDELTA 13C C3-29.6per mil
SOPDELTA 13C nC4-29.1per mil
SOPDELTA D C1-268per mil
SOPETHANE10.94MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.44MOL %0.005
SOPISOPENTANE0.16MOL %0.005
SOPMETHANE80.62MOL %0.005
SOPNITROGEN (N2)1.52MOL %0.005
SOPOXYGEN + ARGON0.2MOL %0.005
SOPPENTANE0.15MOL %0.005
SOPPROPANE4.32MOL %0.005
SOPSPECIFIC GRAVITY0.69None

 Sample ID:   617126     Sample Date:  11/1/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 617126    Dolan Integration Group ID: DIG-020879
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS404BTU/cuft
SOPBUTANENDMOL %0.005ND
SOPC6+ (hexanes +)0.01MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-54.2per mil
SOPDELTA D C1-253per mil
SOPETHANE0.06MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN96.91MOL %0.005
SOPISOBUTANENDMOL %0.005ND
SOPISOPENTANENDMOL %0.005ND
SOPMETHANE1.02MOL %0.005
SOPNITROGEN (N2)1.81MOL %0.005
SOPOXYGEN + ARGON0.17MOL %0.005
SOPPENTANENDMOL %0.005ND
SOPPROPANE0.02MOL %0.005
SOPSPECIFIC GRAVITY0.852None