Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#452913 Information View DocsDoc View GISGIS
Sample Site ID452913
FacilityTypeOGProj Number
CountyADAMS - 001LocationNENW 7 1S67W
Elevation5127Lat/Long39.983706/-104.933671
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-001-10094Well Name:B-Farm LD 18-392HC
Well Status:PROperator Name:PDC ENERGY INC
Location:NENW  7  1S  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   643814     Sample Date:  11/04/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 643814    Dolan Integration Group ID: DIG-030026
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS352BTU/cuft
SOPBUTANE0.299MOL %0.005
SOPC6+ (hexanes +)0.049MOL %0.005
SOPCARBON DIOXIDE0.521MOL %0.005
SOPDELTA 13C C1-47per mil
SOPDELTA 13C C2-33.6per mil
SOPDELTA 13C C3-30.5per mil
SOPDELTA 13C CO21per mil
SOPDELTA 13C nC4-28.4per mil
SOPDELTA D C1-270per mil
SOPETHANE3.939MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.099MOL %0.005
SOPISOBUTANE0.138MOL %0.005
SOPISOPENTANE0.042MOL %0.005
SOPMETHANE22.233MOL %0.005
SOPNITROGEN (N2)70.321MOL %0.005
SOPOXYGEN + ARGON0.861MOL %0.005
SOPPENTANE0.039MOL %0.005
SOPPROPANE1.458MOL %0.005
SOPSPECIFIC GRAVITY0.897No Unit

 Sample ID:   643815     Sample Date:  11/04/2022     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 643815    Dolan Integration Group ID: DIG-030025
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1225BTU/cuft
SOPBUTANE1.115MOL %0.005
SOPC6+ (hexanes +)0.11MOL %0.005
SOPCARBON DIOXIDE1.858MOL %0.005
SOPDELTA 13C C1-48.5per mil
SOPDELTA 13C C2-34per mil
SOPDELTA 13C C3-31.2per mil
SOPDELTA 13C CO22.5per mil
SOPDELTA 13C nC4-30.4per mil
SOPDELTA D C1-269per mil
SOPETHANE14.294MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.493MOL %0.005
SOPISOPENTANE0.169MOL %0.005
SOPMETHANE75.608MOL %0.005
SOPNITROGEN (N2)0.726MOL %0.005
SOPOXYGEN + ARGONNDMOL %0.005ND
SOPPENTANE0.165MOL %0.005
SOPPROPANE5.458MOL %0.005
SOPSPECIFIC GRAVITY0.729No Unit

 Sample ID:   615209     Sample Date:  08/05/2019     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 615209    Dolan Integration Group ID: DIG-020801
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-TrimethylcyclopentaneNDAREA COUNT1ND
G02G1,1,3-TrimethylcyclopentaneNDppm10ND
G02G1,1-dimethylcyclopentaneNDAREA COUNT1ND
G02G1,1-dimethylcyclopentaneNDppm10ND
G02G1,2,3-trimethylcyclopentane0.534AREA COUNT1
G02G1,2,3-trimethylcyclopentane53ppm10
G02G1,2,4-trimethylcyclopentane1.389AREA COUNT1
G02G1,2,4-trimethylcyclopentane137ppm10
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,2-DIMETHYLBUTANENDppm10ND
G02G2,2-dimethylpentaneNDAREA COUNT1ND
G02G2,2-dimethylpentaneNDppm10ND
G02G2,3-DIMETHYLBUTANENDAREA COUNT1ND
G02G2,3-DIMETHYLBUTANENDppm10ND
G02G2,3-dimethylpentane0.368AREA COUNT1
G02G2,3-dimethylpentane36ppm10
G02G2,4-dimethylpentaneNDAREA COUNT1ND
G02G2,4-dimethylpentaneNDppm10ND
G02G2-METHYLPENTANE0.421AREA COUNT1
G02G2-METHYLPENTANE40ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane1.049AREA COUNT1
G02G3-methylhexane101ppm10
G02G3-METHYLPENTANE0.348AREA COUNT1
G02G3-METHYLPENTANE33ppm10
G02GBENZENE0.428AREA COUNT1
G02GBENZENE38ppm10
G02GBUTANENDAREA COUNT1ND
G02GBUTANENDppm10ND
G02Gcis-1,3-dimethylcyclopentane0.462AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane45ppm10
G02GCYCLOHEXANE1.432AREA COUNT1
G02GCYCLOHEXANE141ppm10
G02GCYCLOPENTANENDAREA COUNT1ND
G02GCYCLOPENTANENDppm10ND
G02GDecane68.702AREA COUNT1
G02GDecane6668ppm10
G02GETHYLBENZENENDAREA COUNT1ND
G02GETHYLBENZENENDppm10ND
G02Gethylcyclopentane0.808AREA COUNT1
G02Gethylcyclopentane80ppm10
G02GHEPTANES, MIXED ISOMERS2.228AREA COUNT1
G02GHEPTANES, MIXED ISOMERS215ppm10
G02GHEXANES0.672AREA COUNT1
G02GHEXANES65ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANENDAREA COUNT1ND
G02GISOBUTANENDppm10ND
G02GISOPENTANE0.342AREA COUNT1
G02GISOPENTANE32ppm10
G02Gisoprenoid C1013.088AREA COUNT1
G02Gisoprenoid C101270ppm10
G02Gisoprenoid C1124.533AREA COUNT1
G02Gisoprenoid C112384ppm10
G02Gisoprenoid C1339.919AREA COUNT1
G02Gisoprenoid C133886ppm10
G02Gisoprenoid C1435.445AREA COUNT1
G02Gisoprenoid C143454ppm10
G02Gisoprenoid C1537.244AREA COUNT1
G02Gisoprenoid C153633ppm10
G02Gisoprenoid C1650.166AREA COUNT1
G02Gisoprenoid C164894ppm10
G02Gisoprenoid C1841.704AREA COUNT1
G02Gisoprenoid C184072ppm10
G02Gisoprenoid C92.987AREA COUNT1
G02Gisoprenoid C9289ppm10
G02Gm-XYLENE7.684AREA COUNT1
G02Gm-XYLENE728ppm10
G02GMETHYL CYCLOHEXANE8.491AREA COUNT1
G02GMETHYL CYCLOHEXANE836ppm10
G02GMETHYLCYCLOPENTANE0.79AREA COUNT1
G02GMETHYLCYCLOPENTANE78ppm10
G02Gn-C11115.146AREA COUNT1
G02Gn-C1111187ppm10
G02Gn-C12113.205AREA COUNT1
G02Gn-C1211010ppm10
G02Gn-C13127.12AREA COUNT1
G02Gn-C1312376ppm10
G02Gn-C14110.382AREA COUNT1
G02Gn-C1410757ppm10
G02Gn-C15108.445AREA COUNT1
G02Gn-C1510579ppm10
G02Gn-C1692.574AREA COUNT1
G02Gn-C169031ppm10
G02Gn-C1789.301AREA COUNT1
G02Gn-C178720ppm10
G02Gn-C1868.058AREA COUNT1
G02Gn-C186646ppm10
G02Gn-C1950.49AREA COUNT1
G02Gn-C194930ppm10
G02Gn-C2039.834AREA COUNT1
G02Gn-C203893ppm10
G02Gn-C2124.327AREA COUNT1
G02Gn-C212378ppm10
G02Gn-C2218.706AREA COUNT1
G02Gn-C221829ppm10
G02Gn-C2312.493AREA COUNT1
G02Gn-C231222ppm10
G02Gn-C249.459AREA COUNT1
G02Gn-C24926ppm10
G02Gn-C255.645AREA COUNT1
G02Gn-C25552ppm10
G02Gn-C265.269AREA COUNT1
G02Gn-C26516ppm10
G02Gn-C273.835AREA COUNT1
G02Gn-C27376ppm10
G02Gn-C283.185AREA COUNT1
G02Gn-C28312ppm10
G02Gn-C291.873AREA COUNT1
G02Gn-C29183ppm10
G02Gn-C301.578AREA COUNT1
G02Gn-C30155ppm10
G02Gn-C311.44AREA COUNT1
G02Gn-C31141ppm10
G02Gn-c321.047AREA COUNT1
G02Gn-c32103ppm10
G02Gn-C33NDAREA COUNT1ND
G02Gn-C33NDppm10ND
G02Gn-C340.845AREA COUNT1
G02Gn-C3483ppm10
G02Gn-C35NDAREA COUNT1ND
G02Gn-C35NDppm10ND
G02Gn-C36NDAREA COUNT1ND
G02Gn-C36NDppm10ND
G02Gn-C37NDAREA COUNT1ND
G02Gn-C37NDppm10ND
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane5.982AREA COUNT1
G02Gn-octane578ppm10
G02GNormal Alkane C927.562AREA COUNT1
G02GNormal Alkane C92670ppm10
G02Go-XYLENE5.863AREA COUNT1
G02Go-XYLENE566ppm10
G02Gp-XYLENE2.575AREA COUNT1
G02Gp-XYLENE253ppm10
G02GPENTANE0.302AREA COUNT1
G02GPENTANE29ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane33.146AREA COUNT1
G02Gphytane3240ppm10
G02Gpristane44.911AREA COUNT1
G02Gpristane4386ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE3.667AREA COUNT1
G02GTOLUENE338ppm10
G02Gtrans-1,2-dimethylcyclopentane0.679AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane67ppm10
G02Gtrans-1,3-dimethylcyclopentane0.33AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane32ppm10
SOPBTX aromatics %0.471%
SOPcarbon preference index (Hunt)0.927Ratio
SOPcarbon preference index (Marzi)0.922Ratio
SOPcycloparaffins %0.66%
SOPisoparaffins % (branched)0.545%
SOPisoprenoids %7.53%
SOPn paraffin %25.857%
SOPnC17/(nC18+nC29) ratio0.979Ratio
SOPnC18/(nC18+nC19) ratio0.574Ratio
SOPphytane/nC18 ratio0.487Ratio
SOPpristane/nC17 ratio0.503Ratio
SOPpristane/phytane ratio1.355Ratio
SOPresolved unknowns %62.022%

 Sample ID:   638603     Sample Date:  06/29/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  

Sample Results for Sample # 638603 ID: 2207004-2
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM1500mg/L100
E200.7MAGNESIUMNDmg/L100U
E200.7POTASSIUM290mg/L100
E200.7SODIUM1100mg/L100

 Sample ID:   638602     Sample Date:  06/29/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  

Sample Results for Sample # 638602 ID: 2207004-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7CALCIUM1500mg/L100
E200.7MAGNESIUMNDmg/L100U
E200.7POTASSIUM310mg/L100
E200.7SODIUM1200mg/L100
E300.0CHLORIDE3500mg/L50
E300.0SULFATE1100mg/L250
RSK175ETHANE78ug/L4
RSK175METHANE560ug/L2
RSK175PROPANE30ug/L6
SM2320BBICARBONATE ALKALINITY as CACO3120mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3230mg/L20
SM2320BTOTAL ALKALINITY AS CACO3350mg/L20
SM2540CTOTAL DISSOLVED SOLIDS11000mg/L400
SW8015TEPH DIESEL RANGE ORGANICS49mg/L1.1
SW8015TVPH - Gasoline Range Organics7.2mg/L5
SW8260BENZENE77ug/L25
SW8260ETHYLBENZENE100ug/L25
SW8260M-+P-XYLENE250ug/L25
SW8260o-XYLENE140ug/L25
SW8260TOLUENE250ug/L25
SW8260TOTAL XYLENES390ug/L1

 Sample ID:   658957     Sample Date:  05/10/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 658957    Dolan Integration Group ID: DIG-035507
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS931BTU/cuft
SOPBUTANE0.312MOL %0.005
SOPC6+ (hexanes +)0.009MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-60.6per mil
SOPDELTA 13C C2-33.2per mil
SOPDELTA 13C C3-29.4per mil
SOPDELTA 13C iC4-31per mil
SOPDelta 13C iC5-28per mil
SOPDELTA 13C nC4-28.3per mil
SOPDelta 13C nC5-28.2per mil
SOPDELTA D C1-258per mil
SOPETHANE2.055MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.113MOL %0.005
SOPHYDROGEN2.105MOL %0.005
SOPISOBUTANE0.147MOL %0.005
SOPISOPENTANE0.055MOL %0.005
SOPMETHANE81.904MOL %0.005
SOPNITROGEN (N2)11.596MOL %0.005
SOPOXYGEN + ARGON0.575MOL %0.005
SOPPENTANE0.052MOL %0.005
SOPPROPANE1.077MOL %0.005
SOPSPECIFIC GRAVITY0.636No Unit

 Sample ID:   658958     Sample Date:  05/10/2024     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 658958    Dolan Integration Group ID: DIG-035508
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1274BTU/cuft
SOPBUTANE2.386MOL %0.005
SOPC6+ (hexanes +)0.15MOL %0.005
SOPCARBON DIOXIDE1.854MOL %0.005
SOPDELTA 13C C1-48per mil
SOPDELTA 13C C2-33.7per mil
SOPDELTA 13C C3-29.9per mil
SOPDELTA 13C CO22.3per mil
SOPDELTA 13C iC4-32.1per mil
SOPDelta 13C iC5-28.5per mil
SOPDELTA 13C nC4-28.5per mil
SOPDelta 13C nC5-28.1per mil
SOPDELTA D C1-269per mil
SOPETHANE14.487MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.918MOL %0.005
SOPISOPENTANE0.508MOL %0.005
SOPMETHANE66.819MOL %0.005
SOPNITROGEN (N2)3.997MOL %0.005
SOPOXYGEN + ARGON0.922MOL %0.005
SOPPENTANE0.513MOL %0.005
SOPPROPANE7.447MOL %0.005
SOPSPECIFIC GRAVITY0.807No Unit