Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#452268 Information View DocsDoc View GISGIS
Sample Site ID452268
FacilityTypeOGProj Number
CountyWELD - 123LocationNWSW 8 1N68W
Elevation5065Lat/Long40.062069/-105.033035
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-45502Well Name:PAPA JO 2-25 35C-17HZ
Well Status:PROperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWSW  8  1N  68W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   620132     Sample Date:  10/01/2020     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 620132    ISOTECH ID: 773093
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0078MOL %0.005
SOPBRITISH THERMAL UNITS1118BTU
SOPBUTANE0.145MOL %0.0001
SOPC6+ (hexanes +)0.0245MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-50.64
SOPDELTA 13C C2-34.09
SOPDELTA 13C C3-28.98
SOPDELTA 13C iC4-30.89
SOPDelta 13C iC5-29.3
SOPDELTA 13C nC4-27.34
SOPDelta 13C nC5-27.5
SOPDELTA D C1-240.2
SOPETHANE9.02MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0251MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.143MOL %0.0001
SOPISOPENTANE0.0228MOL %0.0001
SOPMETHANE86.83MOL %0.0002
SOPNITROGEN (N2)1.14MOL %0.01
SOPOXYGEN (O2)0.06MOL %0.01
SOPPENTANE0.0201MOL %0.0001
SOPPROPANE2.56MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.633RATIO_AIR

 Sample ID:   620133     Sample Date:  10/01/2020     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 620133    ISOTECH ID: 773092
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.938MOL %0.005
SOPBUTANENDMOL %0.0001ND
SOPC6+ (hexanes +)NDMOL %0.0001ND
SOPCARBON DIOXIDE0.099MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPETHANENDMOL %0.0001ND
SOPETHENENDMOL %0.0001ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANENDMOL %0.0001ND
SOPISOPENTANENDMOL %0.0001ND
SOPMETHANE0.0009MOL %0.0002
SOPNITROGEN (N2)77.91MOL %0.01
SOPOXYGEN (O2)21.05MOL %0.01
SOPPENTANENDMOL %0.0001ND
SOPPROPANENDMOL %0.0001ND
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY1.001RATIO_AIR

 Sample ID:   643543     Sample Date:  08/30/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 643543    ISOTECH ID: 840859
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1245BTU
SOPBUTANE1.55MOL %0.0001
SOPC6+ (hexanes +)0.0927MOL %0.0001
SOPCARBON DIOXIDE1.72MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.3
SOPDELTA 13C C2-31.3
SOPDELTA 13C C3-28.2
SOPDELTA 13C CO23.1
SOPDELTA 13C iC4-31.2
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-27.2
SOPDelta 13C nC5-27
SOPDELTA D C1-233
SOPETHANE12.61MOL %0.0001
SOPETHENE0.0047MOL %0.0001
SOPHelium0.0118MOL %0.005
SOPHYDROGEN0.274MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.761MOL %0.0001
SOPISOPENTANE0.401MOL %0.0001
SOPMETHANE76.8MOL %0.0002
SOPNITROGEN (N2)0.31MOL %0.01
SOPOXYGEN (O2)0.011MOL %0.01
SOPPENTANE0.333MOL %0.0001
SOPPROPANE5.12MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.731RATIO_AIR

 Sample ID:   643542     Sample Date:  08/30/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BT     Lab:  ISOTECH

Sample Results for Sample # 643542    ISOTECH ID: 840860
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0064MOL %0.005
SOPBRITISH THERMAL UNITS1161BTU
SOPBUTANE0.33MOL %0.0001
SOPC6+ (hexanes +)0.0657MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-50.6
SOPDELTA 13C C2-33.7
SOPDELTA 13C C3-29.1
SOPDELTA 13C iC4-31
SOPDelta 13C iC5-28.4
SOPDELTA 13C nC4-26.9
SOPDelta 13C nC5-27.7
SOPDELTA D C1-245
SOPETHANE9.87MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0329MOL %0.005
SOPHYDROGEN0.28MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.323MOL %0.0001
SOPISOPENTANE0.0431MOL %0.0001
SOPMETHANE83.48MOL %0.0002
SOPNITROGEN (N2)1.19MOL %0.01
SOPOXYGEN (O2)0.015MOL %0.01
SOPPENTANE0.0369MOL %0.0001
SOPPROPANE4.33MOL %0.0001
SOPPROPENE0.0001MOL %0.0001
SOPSPECIFIC GRAVITY0.66RATIO_AIR

 Sample ID:   660348     Sample Date:  04/18/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 660348    ISOTECH ID: 919648
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.016MOL %0.005
SOPBRITISH THERMAL UNITS1138BTU
SOPBUTANE0.266MOL %0.0001
SOPC6+ (hexanes +)0.0637MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.2
SOPDELTA 13C C2-34.2
SOPDELTA 13C C3-29.6
SOPDELTA 13C iC4-31.3
SOPDelta 13C iC5-28.8
SOPDELTA 13C nC4-27.4
SOPDelta 13C nC5-27.9
SOPDELTA D C1-243
SOPETHANE9.76MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0179MOL %0.0025
SOPHYDROGEN0.279MOL %0.0025
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.259MOL %0.0001
SOPISOPENTANE0.0333MOL %0.0001
SOPMETHANE83.68MOL %0.0002
SOPNITROGEN (N2)1.67MOL %0.01
SOPOXYGEN (O2)0.32MOL %0.01
SOPPENTANE0.0296MOL %0.0001
SOPPROPANE3.61MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.654RATIO_AIR

 Sample ID:   660349     Sample Date:  04/18/2024     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 660349    ISOTECH ID: 919647
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1246BTU
SOPBUTANE1.5MOL %0.0001
SOPC6+ (hexanes +)0.0144MOL %0.0001
SOPCARBON DIOXIDE1.79MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.6
SOPDELTA 13C C2-31.2
SOPDELTA 13C C3-28.5
SOPDELTA 13C CO22.8
SOPDELTA 13C iC4-31.5
SOPDelta 13C iC5-28.2
SOPDELTA 13C nC4-27.4
SOPDelta 13C nC5-26.9
SOPDELTA D C1-233
SOPETHANE13.48MOL %0.0001
SOPETHENE0.0168MOL %0.0001
SOPHelium0.0085MOL %0.0025
SOPHYDROGEN0.0779MOL %0.0025
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.761MOL %0.0001
SOPISOPENTANE0.313MOL %0.0001
SOPMETHANE76.14MOL %0.0002
SOPNITROGEN (N2)0.3MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.212MOL %0.0001
SOPPROPANE5.4MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.733RATIO_AIR

 Sample ID:   668333     Sample Date:  04/07/2025     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 668333    ISOTECH ID: 962959
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1303BTU
SOPBUTANE2.29MOL %0.0001
SOPC6+ (hexanes +)0.0488MOL %0.0001
SOPCARBON DIOXIDE1.97MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.8
SOPDELTA 13C C2-31.4
SOPDELTA 13C C3-28.1
SOPDELTA 13C CO22.5
SOPDELTA 13C iC4-31.3
SOPDelta 13C iC5-28.5
SOPDELTA 13C nC4-28
SOPDelta 13C nC5-27.5
SOPDELTA D C1-232
SOPETHANE13.62MOL %0.0001
SOPETHENE0.0178MOL %0.0001
SOPHelium0.007MOL %0.0025
SOPHYDROGEN0.168MOL %0.0025
SOPISOBUTANE0.987MOL %0.0001
SOPISOPENTANE0.725MOL %0.0001
SOPMETHANE72.94MOL %0.0002
SOPNITROGEN (N2)0.43MOL %0.01
SOPOXYGEN (O2)0.083MOL %0.01
SOPPENTANE0.663MOL %0.0001
SOPPROPANE6.05MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.775RATIO_AIR

 Sample ID:   668332     Sample Date:  04/07/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 668332    ISOTECH ID: 962960
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.017MOL %0.005
SOPBRITISH THERMAL UNITS1199BTU
SOPBUTANE0.372MOL %0.0001
SOPC6+ (hexanes +)0.102MOL %0.0001
SOPCARBON DIOXIDE0.009MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.1
SOPDELTA 13C C2-34
SOPDELTA 13C C3-29.3
SOPDELTA 13C iC4-31.2
SOPDelta 13C iC5-28.7
SOPDELTA 13C nC4-27.5
SOPDelta 13C nC5-27.3
SOPDELTA D C1-247
SOPETHANE13.7MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0104MOL %0.0025
SOPHYDROGEN0.212MOL %0.0025
SOPISOBUTANE0.35MOL %0.0001
SOPISOPENTANE0.0648MOL %0.0001
SOPMETHANE78.32MOL %0.0002
SOPNITROGEN (N2)1.43MOL %0.01
SOPOXYGEN (O2)0.37MOL %0.01
SOPPENTANE0.0657MOL %0.0001
SOPPROPANE4.98MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.691RATIO_AIR