Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#438868 Information View DocsDoc View GISGIS
Sample Site ID438868
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSW 29 2N65W
Elevation4943Lat/Long40.103322/-104.693786
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-40173Well Name:SUMMIT 4C-29HZ
Well Status:PROperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSW  29 2N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   611467     Sample Date:  08/22/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 611467    ISOTECH ID: 731916
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0122MOL %0.005
SOPBRITISH THERMAL UNITS889BTU
SOPBUTANE0.0426MOL %0.0001
SOPC6+ (hexanes +)0.001MOL %0.0001
SOPCARBON DIOXIDE0.009MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.34
SOPDELTA 13C C2-33.03
SOPDELTA 13C C3-29.08
SOPDELTA 13C iC4-30.75
SOPDELTA D C1-253.6
SOPETHANE10.38MOL %0.0001
SOPETHENE0.0001MOL %0.0001
SOPHelium0.0066MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.0864MOL %0.0001
SOPISOPENTANE0.0004MOL %0.0001
SOPMETHANE62.65MOL %0.0002
SOPNITROGEN (N2)24.25MOL %0.01
SOPOXYGEN (O2)NDMOL %0.01ND
SOPPENTANE0.0005MOL %0.0001
SOPPROPANE2.56MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.731RATIO_AIR

 Sample ID:   611465     Sample Date:  08/22/2019     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 611465    Accutest ID: DA18899-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.7BORONNDmg/L1U
E200.7CALCIUM97.7mg/L0.4
E200.7IRON0.185mg/L0.01
E200.7MAGNESIUMNDmg/L0.2U
E200.7MANGANESENDmg/L0.005U
E200.7POTASSIUM902mg/L20
E200.7SODIUM2800mg/L8
E200.7STRONTIUM4.55mg/L0.1
E200.8BARIUM1.05mg/L0.004
E200.8SELENIUM0.0435mg/L0.0008
E300.0BROMIDE6mg/L2.5
E300.0CHLORIDE1040mg/L250
E300.0FLUORIDENDmg/L5U
E300.0NITRATE13.4mg/L0.5
E300.0Nitrite as NO225.4mg/L2
E300.0SULFATE127mg/L25
FIELDpH, FIELD12.9SU
FIELDSPECIFIC CONDUCTIVITY, FIELD1650UMHOS/CM0.5
FIELDTEMPERATURE, FIELD29.1degrees C
SM1030CATION - ANION BALANCE0.04%
SM2320BBICARBONATE ALKALINITY as CACO3NDmg/L5U
SM2320BCARBONATE ALKALINITY AS CACO3525mg/L5
SM2320BTOTAL ALKALINITY AS CACO35900mg/L5
SW8015TVPH - Gasoline Range Organics2.19mg/L1.3
SW8260BENZENE225ug/L25
SW8260ETHYLBENZENENDug/L25U
SW8260M-+P-XYLENE30.8ug/L25
SW8260o-XYLENENDug/L25U
SW8260TOLUENE161ug/L25
SW8260TOTAL XYLENES30.8ug/L25

 Sample ID:   611466     Sample Date:  08/22/2019     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 611466    Accutest ID: DA18900-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   672011     Sample Date:  08/04/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 672011    ISOTECH ID: 982601
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0738MOL %0.005
SOPBRITISH THERMAL UNITS1075BTU
SOPBUTANE0.812MOL %0.0001
SOPC6+ (hexanes +)0.159MOL %0.0001
SOPCARBON DIOXIDE0.014MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.7
SOPDELTA 13C C2-33.8
SOPDELTA 13C C3-29.8
SOPDELTA 13C iC4-32.1
SOPDelta 13C iC5-28.7
SOPDELTA 13C nC4-28.8
SOPDelta 13C nC5-28.3
SOPDELTA D C1-256
SOPETHANE10.66MOL %0.0001
SOPETHENE0.002MOL %0.0001
SOPHelium0.0109MOL %0.0025
SOPHYDROGEN7.01MOL %0.0025
SOPISOBUTANE0.388MOL %0.0001
SOPISOPENTANE0.155MOL %0.0001
SOPMETHANE69.17MOL %0.0002
SOPNITROGEN (N2)7.01MOL %0.01
SOPOXYGEN (O2)0.37MOL %0.01
SOPPENTANE0.159MOL %0.0001
SOPPROPANE4MOL %0.0001
SOPPROPENE0.0017MOL %0.0001
SOPSPECIFIC GRAVITY0.669RATIO_AIR

 Sample ID:   672012     Sample Date:  08/04/2025     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 672012    ISOTECH ID: 982600
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0102MOL %0.005
SOPBRITISH THERMAL UNITS1228BTU
SOPBUTANE1.21MOL %0.0001
SOPC6+ (hexanes +)0.0314MOL %0.0001
SOPCARBON DIOXIDE2.2MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.1
SOPDELTA 13C C2-33.4
SOPDELTA 13C C3-29.7
SOPDELTA 13C CO22.4
SOPDELTA 13C iC4-31.8
SOPDelta 13C iC5-28.3
SOPDELTA 13C nC4-28.3
SOPDelta 13C nC5-27.8
SOPDELTA D C1-257
SOPETHANE14.01MOL %0.0001
SOPETHENE0.0001MOL %0.0001
SOPHelium0.0088MOL %0.0025
SOPHYDROGEN0.005MOL %0.0025
SOPISOBUTANE0.599MOL %0.0001
SOPISOPENTANE0.151MOL %0.0001
SOPMETHANE74.45MOL %0.0002
SOPNITROGEN (N2)1.06MOL %0.01
SOPOXYGEN (O2)0.2MOL %0.01
SOPPENTANE0.12MOL %0.0001
SOPPROPANE5.96MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.738RATIO_AIR

 Sample ID:   659771     Sample Date:  04/02/2024     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 659771    ISOTECH ID: 917935
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1274BTU
SOPBUTANE1.74MOL %0.0001
SOPC6+ (hexanes +)0.122MOL %0.0001
SOPCARBON DIOXIDE2.21MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-49.5
SOPDELTA 13C C2-33.9
SOPDELTA 13C C3-29.9
SOPDELTA 13C CO22.8
SOPDELTA 13C iC4-32.1
SOPDelta 13C iC5-28.5
SOPDELTA 13C nC4-28.7
SOPDelta 13C nC5-27.9
SOPDELTA D C1-260
SOPETHANE14.19MOL %0.0001
SOPETHENE0.0002MOL %0.0001
SOPHelium0.0089MOL %0.0025
SOPHYDROGEN0.0034MOL %0.0025
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.744MOL %0.0001
SOPISOPENTANE0.267MOL %0.0001
SOPMETHANE73.21MOL %0.0002
SOPNITROGEN (N2)0.53MOL %0.01
SOPOXYGEN (O2)0.041MOL %0.01
SOPPENTANE0.259MOL %0.0001
SOPPROPANE6.67MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.76RATIO_AIR

 Sample ID:   659767     Sample Date:  04/02/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 659767    ISOTECH ID: 917011
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.42MOL %0.005
SOPBRITISH THERMAL UNITS908BTU
SOPBUTANE0.399MOL %0.0001
SOPC6+ (hexanes +)0.0866MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDE0.13MOL %0.01
SOPDELTA 13C C1-48.61
SOPDELTA 13C C2-33.33
SOPDELTA 13C C3-29.78
SOPDELTA 13C iC4-32
SOPDELTA 13C nC4-28.3
SOPDELTA D C1-239.2
SOPETHANE13.59MOL %0.0001
SOPETHENE0.0075MOL %0.0001
SOPHELIUM DILUTION FACTOR0.76NA
SOPHYDROGENNDMOL %0.0025ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.157MOL %0.0001
SOPISOPENTANE0.036MOL %0.0001
SOPMETHANE53.97MOL %0.0002
SOPNITROGEN (N2)24.99MOL %0.01
SOPOXYGEN (O2)2.51MOL %0.01
SOPPENTANE0.0397MOL %0.0001
SOPPROPANE3.66MOL %0.0001
SOPPROPENE0.0066MOL %0.0001
SOPSPECIFIC GRAVITY0.788RATIO_AIR

 Sample ID:   659768     Sample Date:  04/02/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 659768    ISOTECH ID: 917011
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.28mg/L0.01
SOPETHANE7.2mg/L0.0002
SOPMETHANE14mg/L0.0002
SOPNITROGEN (N2)10mg/L0.02
SOPPROPANE2.7mg/L0.0003

 Sample ID:   659769     Sample Date:  04/02/2024     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 659769    Accutest ID: DA63426-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
FIELDpH, FIELD13.5SU
FIELDSPECIFIC CONDUCTIVITY, FIELD28.9umhos/cm0.5
FIELDTEMPERATURE, FIELD10degrees C
SW8260BENZENE329ug/L10
SW8260ETHYLBENZENE7.4ug/L10J
SW8260M-+P-XYLENE31.3ug/L10
SW8260o-XYLENE13ug/L10
SW8260TOLUENE173ug/L10
SW8260TOTAL XYLENES44.3ug/L10

 Sample ID:   659770     Sample Date:  04/02/2024     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 659770    Accutest ID: DA63427-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range OrganicsNDmg/L0.05U
SW8260BENZENENDug/L1U
SW8260ETHYLBENZENENDug/L1U
SW8260M-+P-XYLENENDug/L1U
SW8260o-XYLENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U