Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#299162 Information View DocsDoc View GISGIS
Sample Site ID299162
FacilityTypeOGProj Number
CountyWELD - 123LocationNENW 9 4N67W
Elevation4775Lat/Long40.33078/-104.89669
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-29279Well Name:GOLD 9NU
Well Status:SIOperator Name:PDC ENERGY INC
Location:NENW  9  4N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   673246     Sample Date:  10/14/2025     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 673246    Dolan Integration Group ID: DIG-041766
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW6010CALCIUM3.1mg/L0.3
SW6010MAGNESIUMNDmg/L0.3U
SW6010POTASSIUM14mg/L0.3
SW6010SODIUM368mg/L0.3
SW8015BENZENE350ug/L100
SW8015ETHYLBENZENE470ug/L100
SW8015TOLUENE1900ug/L100
SW8015TOTAL XYLENESNDug/L250U
SW8015TVPH - Gasoline Range Organics21800ug/L100

 Sample ID:   637358     Sample Date:  05/03/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 637358    Dolan Integration Group ID: DIG-027811
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1124BTU/cuft
SOPBUTANE0.577MOL %0.005
SOPC6+ (hexanes +)0.152MOL %0.005
SOPCARBON DIOXIDE1.79MOL %0.005
SOPDELTA 13C C1-48per mil
SOPDELTA 13C C2-32.6per mil
SOPDELTA 13C C3-28.7per mil
SOPDELTA 13C CO22.7per mil
SOPDELTA D C1-261per mil
SOPETHANE11.318MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.273MOL %0.005
SOPISOPENTANE0.134MOL %0.005
SOPMETHANE79.036MOL %0.005
SOPNITROGEN (N2)2.836MOL %0.005
SOPOXYGEN + ARGON0.606MOL %0.005
SOPPENTANE0.156MOL %0.005
SOPPROPANE3.12MOL %0.005
SOPSPECIFIC GRAVITY0.693No Unit

 Sample ID:   637359     Sample Date:  05/03/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 637359    Dolan Integration Group ID: DIG-027812
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1156BTU/cuft
SOPBUTANE0.604MOL %0.005
SOPC6+ (hexanes +)0.186MOL %0.005
SOPCARBON DIOXIDE1.85MOL %0.005
SOPDELTA 13C C1-47.9per mil
SOPDELTA 13C C2-32.3per mil
SOPDELTA 13C C3-29.3per mil
SOPDELTA 13C CO22.9per mil
SOPDELTA D C1-260per mil
SOPETHANE11.631MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.284MOL %0.005
SOPISOPENTANE0.142MOL %0.005
SOPMETHANE81.068MOL %0.005
SOPNITROGEN (N2)0.776MOL %0.005
SOPOXYGEN + ARGON0.063MOL %0.005
SOPPENTANE0.169MOL %0.005
SOPPROPANE3.226MOL %0.005
SOPSPECIFIC GRAVITY0.686No Unit

 Sample ID:   637360     Sample Date:  05/03/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  

Sample Results for Sample # 637360 ID: 2205089-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8CALCIUM13mg/L10
E200.8MAGNESIUM3.2mg/L1
E200.8POTASSIUM11mg/L10
E200.8SODIUM290mg/L10
E300.0CHLORIDE72mg/L4
E300.0SULFATE270mg/L20
RSK175ETHANE6000ug/L20
RSK175METHANE9300ug/L10
RSK175PROPANE4700ug/L10
SM2320BBICARBONATE ALKALINITY as CACO3120mg/L20
SM2320BCARBONATE ALKALINITY AS CACO3120mg/L20
SM2320BTOTAL ALKALINITY AS CACO3230mg/L20
SM2540CTOTAL DISSOLVED SOLIDS950mg/L40
SW8015TEPH DIESEL RANGE ORGANICS26mg/L1
SW8260BENZENE210ug/L50
SW8260ETHYLBENZENE210ug/L50
SW8260M-+P-XYLENE850ug/L50
SW8260o-XYLENE450ug/L50
SW8260TOLUENE930ug/L50
SW8260TOTAL XYLENES1300ug/L1
SW8260TVPH - Gasoline Range Organics16000ug/L5000

 Sample ID:   658239     Sample Date:  04/05/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 658239    Dolan Integration Group ID: DIG-035138
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1278BTU/cuft
SOPBUTANE2.181MOL %0.005
SOPC6+ (hexanes +)0.172MOL %0.005
SOPCARBON DIOXIDE1.765MOL %0.005
SOPDELTA 13C C1-47.2per mil
SOPDELTA 13C C2-32.5per mil
SOPDELTA 13C C3-29.1per mil
SOPDELTA 13C CO23.1per mil
SOPDELTA 13C iC4-31.4per mil
SOPDelta 13C iC5-28.2per mil
SOPDELTA 13C nC4-27.6per mil
SOPDelta 13C nC5-27.3per mil
SOPDELTA D C1-259per mil
SOPETHANE15.346MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.065MOL %0.005
SOPISOBUTANE0.988MOL %0.005
SOPISOPENTANE0.338MOL %0.005
SOPMETHANE66.264MOL %0.005
SOPNITROGEN (N2)3.625MOL %0.005
SOPOXYGEN + ARGON1.031MOL %0.005
SOPPENTANE0.308MOL %0.005
SOPPROPANE7.919MOL %0.005
SOPSPECIFIC GRAVITY0.805No Unit

 Sample ID:   658240     Sample Date:  04/05/2024     Matrix:  GAS     Collection Point:  PRD     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 658240    Dolan Integration Group ID: DIG-035139
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1342BTU/cuft
SOPBUTANE2.487MOL %0.005
SOPC6+ (hexanes +)0.185MOL %0.005
SOPCARBON DIOXIDE1.813MOL %0.005
SOPDELTA 13C C1-48.1per mil
SOPDELTA 13C C2-32.9per mil
SOPDELTA 13C C3-29.2per mil
SOPDELTA 13C CO23per mil
SOPDELTA 13C iC4-31.7per mil
SOPDelta 13C iC5-28.7per mil
SOPDELTA 13C nC4-27.6per mil
SOPDelta 13C nC5-27.4per mil
SOPDELTA D C1-260per mil
SOPETHANE15.928MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE1.139MOL %0.005
SOPISOPENTANE0.372MOL %0.005
SOPMETHANE67.891MOL %0.005
SOPNITROGEN (N2)0.926MOL %0.005
SOPOXYGEN + ARGON0.213MOL %0.005
SOPPENTANE0.33MOL %0.005
SOPPROPANE8.714MOL %0.005
SOPSPECIFIC GRAVITY0.809No Unit