Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#295880 Information View DocsDoc View GISGIS
Sample Site ID295880
FacilityTypeOGProj Number
CountyWELD - 123LocationSESW 29 3N65W
Elevation4877Lat/Long40.190442/-104.689075
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-25835Well Name:WARDELL 23-29
Well Status:SIOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SESW  29 3N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   642931     Sample Date:  08/08/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 642931    ISOTECH ID: 838169
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0117MOL %0.005
SOPBRITISH THERMAL UNITS1181BTU
SOPBUTANE0.959MOL %0.0001
SOPC6+ (hexanes +)0.163MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.9
SOPDELTA 13C C2-32.3
SOPDELTA 13C C3-28.3
SOPDELTA 13C iC4-31.1
SOPDelta 13C iC5-28.1
SOPDELTA 13C nC4-27.2
SOPDelta 13C nC5-26.7
SOPDELTA D C1-240
SOPETHANE8.81MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0201MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.557MOL %0.0001
SOPISOPENTANE0.287MOL %0.0001
SOPMETHANE83.82MOL %0.0002
SOPNITROGEN (N2)1.22MOL %0.01
SOPOXYGEN (O2)0.14MOL %0.01
SOPPENTANE0.206MOL %0.0001
SOPPROPANE3.81MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.675RATIO_AIR

 Sample ID:   642933     Sample Date:  08/08/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 642933    ISOTECH ID: 838168
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1210BTU
SOPBUTANE1.16MOL %0.0001
SOPC6+ (hexanes +)0.213MOL %0.0001
SOPCARBON DIOXIDE2.2MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.1
SOPDELTA 13C C2-30.3
SOPDELTA 13C C3-27.1
SOPDELTA 13C CO22.2
SOPDELTA 13C iC4-30.3
SOPDelta 13C iC5-27.8
SOPDELTA 13C nC4-26.6
SOPDelta 13C nC5-26.4
SOPDELTA D C1-233
SOPETHANE11.68MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0083MOL %0.005
SOPHYDROGEN0.054MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.635MOL %0.0001
SOPISOPENTANE0.28MOL %0.0001
SOPMETHANE78.81MOL %0.0002
SOPNITROGEN (N2)0.28MOL %0.01
SOPOXYGEN (O2)0.022MOL %0.01
SOPPENTANE0.245MOL %0.0001
SOPPROPANE4.41MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.717RATIO_AIR

 Sample ID:   642932     Sample Date:  08/08/2022     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 642932    Dolan Integration Group ID: DIG-028799
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
CALCBTX aromatics %0.865%
CALCcarbon preference index (Hunt)1.02Ratio
CALCcarbon preference index (Marzi)1.013Ratio
CALCcycloparaffins %1.487%
CALCisoparaffins % (branched)2.087%
CALCisoprenoids %7.012%
CALCn paraffin %42.953%
CALCnC17/(nC18+nC29) ratio0.907Ratio
CALCnC18/(nC18+nC19) ratio0.548Ratio
CALCphytane/nC18 ratio0.289Ratio
CALCpristane/nC17 ratio0.466Ratio
CALCpristane/phytane ratio1.999Ratio
CALCresolved unknowns %44.164%
G02G1,1,3-Trimethylcyclopentane2.546AREA COUNT1
G02G1,1,3-Trimethylcyclopentane210ppm10
G02G1,1-dimethylcyclopentane2.955AREA COUNT1
G02G1,1-dimethylcyclopentane244ppm10
G02G1,2,3-trimethylcyclopentane1.163AREA COUNT1
G02G1,2,3-trimethylcyclopentane96ppm10
G02G1,2,4-trimethylcyclopentane1.77AREA COUNT1
G02G1,2,4-trimethylcyclopentane146ppm10
G02G2,2,3-trimethylbutaneNDAREA COUNT1ND
G02G2,2,3-trimethylbutaneNDppm10ND
G02G2,2-DIMETHYLBUTANE1.58AREA COUNT1
G02G2,2-DIMETHYLBUTANE127ppm10
G02G2,2-dimethylpentane1.673AREA COUNT1
G02G2,2-dimethylpentane135ppm10
G02G2,3-DIMETHYLBUTANE5.341AREA COUNT1
G02G2,3-DIMETHYLBUTANE441ppm10
G02G2,3-dimethylpentane3.214AREA COUNT1
G02G2,3-dimethylpentane260ppm10
G02G2,4-dimethylpentane3.281AREA COUNT1
G02G2,4-dimethylpentane265ppm10
G02G2-methylhexane15.306AREA COUNT1
G02G2-methylhexane1237ppm10
G02G2-METHYLPENTANE26.748AREA COUNT1
G02G2-METHYLPENTANE2156ppm10
G02G3-ethylpentaneNDAREA COUNT1ND
G02G3-ethylpentaneNDppm10ND
G02G3-methylhexane14.244AREA COUNT1
G02G3-methylhexane1151ppm10
G02G3-METHYLPENTANE16.301AREA COUNT1
G02G3-METHYLPENTANE1314ppm10
G02GBENZENE3.815AREA COUNT1
G02GBENZENE281ppm10
G02GBUTANE24.36AREA COUNT1
G02GBUTANE1939ppm10
G02Gcis-1,3-dimethylcyclopentane3.523AREA COUNT1
G02Gcis-1,3-dimethylcyclopentane291ppm10
G02GCYCLOHEXANE23.653AREA COUNT1
G02GCYCLOHEXANE1951ppm10
G02GCYCLOPENTANE2.794AREA COUNT1
G02GCYCLOPENTANE230ppm10
G02GDecane269.639AREA COUNT1
G02GDecane21931ppm10
G02GETHYLBENZENE2.643AREA COUNT1
G02GETHYLBENZENE212ppm10
G02Gethylcyclopentane1.489AREA COUNT1
G02Gethylcyclopentane123ppm10
G02GHeptane33.324AREA COUNT1
G02GHeptane2694ppm10
G02GHEXANES41.252AREA COUNT1
G02GHEXANES3325ppm10
G02Ghighly branched C25 isoprenoidNDAREA COUNT1ND
G02Ghighly branched C25 isoprenoidNDppm10ND
G02GISOBUTANE6.827AREA COUNT1
G02GISOBUTANE525ppm10
G02GISOPENTANE32.51AREA COUNT1
G02GISOPENTANE2537ppm10
G02Gisoprenoid C1026.671AREA COUNT1
G02Gisoprenoid C102169ppm10
G02Gisoprenoid C1147.659AREA COUNT1
G02Gisoprenoid C113880ppm10
G02Gisoprenoid C1386.809AREA COUNT1
G02Gisoprenoid C137082ppm10
G02Gisoprenoid C1473.848AREA COUNT1
G02Gisoprenoid C146031ppm10
G02Gisoprenoid C1566.703AREA COUNT1
G02Gisoprenoid C155453ppm10
G02Gisoprenoid C1693.691AREA COUNT1
G02Gisoprenoid C167659ppm10
G02Gisoprenoid C1874.304AREA COUNT1
G02Gisoprenoid C186080ppm10
G02Gisoprenoid C92.213AREA COUNT1
G02Gisoprenoid C9180ppm10
G02Gm-XYLENE28.272AREA COUNT1
G02Gm-XYLENE2244ppm10
G02GMETHYL CYCLOHEXANE44.691AREA COUNT1
G02GMETHYL CYCLOHEXANE3687ppm10
G02GMETHYLCYCLOPENTANE19.983AREA COUNT1
G02GMETHYLCYCLOPENTANE1648ppm10
G02Gn-C11408.219AREA COUNT1
G02Gn-C1133236ppm10
G02Gn-C12416.793AREA COUNT1
G02Gn-C1233969ppm10
G02Gn-C13385.23AREA COUNT1
G02Gn-C1331428ppm10
G02Gn-C14311.147AREA COUNT1
G02Gn-C1425410ppm10
G02Gn-C15284.705AREA COUNT1
G02Gn-C1523274ppm10
G02Gn-C16225.823AREA COUNT1
G02Gn-C1618460ppm10
G02Gn-C17203.378AREA COUNT1
G02Gn-C1716642ppm10
G02Gn-C18164.194AREA COUNT1
G02Gn-C1813436ppm10
G02Gn-C19135.513AREA COUNT1
G02Gn-C1911089ppm10
G02Gn-C20125.325AREA COUNT1
G02Gn-C2010264ppm10
G02Gn-C2198.658AREA COUNT1
G02Gn-C218083ppm10
G02Gn-C2285.988AREA COUNT1
G02Gn-C227047ppm10
G02Gn-C2375.519AREA COUNT1
G02Gn-C236191ppm10
G02Gn-C2463.251AREA COUNT1
G02Gn-C245187ppm10
G02Gn-C2552.604AREA COUNT1
G02Gn-C254314ppm10
G02Gn-C2645.118AREA COUNT1
G02Gn-C263701ppm10
G02Gn-C2734.476AREA COUNT1
G02Gn-C272829ppm10
G02Gn-C2826.529AREA COUNT1
G02Gn-C282177ppm10
G02Gn-C2920.903AREA COUNT1
G02Gn-C291716ppm10
G02Gn-C3015.896AREA COUNT1
G02Gn-C301305ppm10
G02Gn-C3114.078AREA COUNT1
G02Gn-C311156ppm10
G02Gn-c3210.014AREA COUNT1
G02Gn-c32822ppm10
G02Gn-C338.327AREA COUNT1
G02Gn-C33684ppm10
G02Gn-C346.983AREA COUNT1
G02Gn-C34574ppm10
G02Gn-C352.872AREA COUNT1
G02Gn-C35236ppm10
G02Gn-C362.772AREA COUNT1
G02Gn-C36220ppm10
G02Gn-C372.191AREA COUNT1
G02Gn-C37174ppm10
G02Gn-C38NDAREA COUNT1ND
G02Gn-C38NDppm10ND
G02Gn-C39NDAREA COUNT1ND
G02Gn-C39NDppm10ND
G02Gn-C40NDAREA COUNT1ND
G02Gn-C40NDppm10ND
G02Gn-C41NDAREA COUNT1ND
G02Gn-C41NDppm10ND
G02Gn-octane33.133AREA COUNT1
G02Gn-octane2684ppm10
G02GNormal Alkane C997.417AREA COUNT1
G02GNormal Alkane C97907ppm10
G02Go-XYLENE12.861AREA COUNT1
G02Go-XYLENE1040ppm10
G02Gp-XYLENE9.476AREA COUNT1
G02Gp-XYLENE782ppm10
G02GPENTANE35.738AREA COUNT1
G02GPENTANE2865ppm10
G02GPHENANTHRENENDAREA COUNT1ND
G02GPHENANTHRENENDppm10ND
G02Gphytane47.404AREA COUNT1
G02Gphytane3883ppm10
G02Gpristane94.774AREA COUNT1
G02Gpristane7755ppm10
G02GPropyl-benzeneNDAREA COUNT1ND
G02GPropyl-benzeneNDppm10ND
G02GTOLUENE18.686AREA COUNT1
G02GTOLUENE1441ppm10
G02Gtrans-1,2-dimethylcyclopentane5.79AREA COUNT1
G02Gtrans-1,2-dimethylcyclopentane478ppm10
G02Gtrans-1,3-dimethylcyclopentane3.199AREA COUNT1
G02Gtrans-1,3-dimethylcyclopentane264ppm10

 Sample ID:   609210     Sample Date:  07/17/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 609210    ISOTECH ID: 727102
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.232MOL %0.005
SOPBRITISH THERMAL UNITS921BTU
SOPBUTANE0.819MOL %0.0001
SOPC6+ (hexanes +)0.224MOL %0.0001
SOPCARBON DIOXIDE0.061MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.92
SOPDELTA 13C C2-32.3
SOPDELTA 13C C3-28.45
SOPDELTA 13C iC4-31.14
SOPDelta 13C iC5-28.23
SOPDELTA 13C nC4-27.39
SOPDelta 13C nC5-26.1
SOPDELTA D C1-233.4
SOPETHANE7.99MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0139MOL %0.005
SOPHYDROGEN0.0494MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.486MOL %0.0001
SOPISOPENTANE0.214MOL %0.0001
SOPMETHANE61.26MOL %0.0002
SOPNITROGEN (N2)19.77MOL %0.01
SOPOXYGEN (O2)5.19MOL %0.01
SOPPENTANE0.179MOL %0.0001
SOPPROPANE3.51MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.771RATIO_AIR

 Sample ID:   609211     Sample Date:  07/17/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 609211    ISOTECH ID: 727101
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0167MOL %0.005
SOPBRITISH THERMAL UNITS1208BTU
SOPBUTANE1.11MOL %0.0001
SOPC6+ (hexanes +)0.261MOL %0.0001
SOPCARBON DIOXIDE1.34MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.3
SOPDELTA 13C C2-30.21
SOPDELTA 13C C3-26.71
SOPDELTA 13C CO20.32
SOPDELTA 13C iC4-30.1
SOPDelta 13C iC5-27.81
SOPDELTA 13C nC4-26.17
SOPDelta 13C nC5-26.4
SOPDELTA D C1-229.6
SOPETHANE12.41MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0058MOL %0.005
SOPHYDROGEN0.0377MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.637MOL %0.0001
SOPISOPENTANE0.239MOL %0.0001
SOPMETHANE77.1MOL %0.0002
SOPNITROGEN (N2)2.06MOL %0.01
SOPOXYGEN (O2)0.011MOL %0.01
SOPPENTANE0.268MOL %0.0001
SOPPROPANE4.5MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.721RATIO_AIR

 Sample ID:   658382     Sample Date:  02/06/2024     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 658382    ISOTECH ID: 909382
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1239BTU
SOPBUTANE1.7MOL %0.0001
SOPC6+ (hexanes +)0.0442MOL %0.0001
SOPCARBON DIOXIDE2.73MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.04
SOPDELTA 13C C2-30.12
SOPDELTA 13C C3-26.91
SOPDELTA 13C CO23.79
SOPDELTA 13C iC4-30.2
SOPDelta 13C iC5-27.86
SOPDELTA 13C nC4-26.46
SOPDelta 13C nC5-26.05
SOPDELTA D C1-227.9
SOPETHANE12.35MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0065MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.851MOL %0.0001
SOPISOPENTANE0.466MOL %0.0001
SOPMETHANE76.24MOL %0.0002
SOPNITROGEN (N2)0.28MOL %0.01
SOPOXYGEN (O2)0.017MOL %0.01
SOPPENTANE0.372MOL %0.0001
SOPPROPANE4.94MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.744RATIO_AIR

 Sample ID:   658381     Sample Date:  02/06/2024     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 658381    ISOTECH ID: 909383
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0246MOL %0.005
SOPBRITISH THERMAL UNITS1172BTU
SOPBUTANE0.988MOL %0.0001
SOPC6+ (hexanes +)0.131MOL %0.0001
SOPCARBON DIOXIDE0.007MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.95
SOPDELTA 13C C2-32.45
SOPDELTA 13C C3-28.44
SOPDELTA 13C iC4-31.09
SOPDelta 13C iC5-28.31
SOPDELTA 13C nC4-27.29
SOPDelta 13C nC5-26.63
SOPDELTA D C1-235.1
SOPETHANE9.19MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0179MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.575MOL %0.0001
SOPISOPENTANE0.3MOL %0.0001
SOPMETHANE81.45MOL %0.0002
SOPNITROGEN (N2)2.57MOL %0.01
SOPOXYGEN (O2)0.46MOL %0.01
SOPPENTANE0.239MOL %0.0001
SOPPROPANE4.05MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.687RATIO_AIR

 Sample ID:   666833     Sample Date:  02/05/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 666833    ISOTECH ID: 956707
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0085MOL %0.005
SOPBRITISH THERMAL UNITS1212BTU
SOPBUTANE1.12MOL %0.0001
SOPC6+ (hexanes +)0.331MOL %0.0001
SOPCARBON DIOXIDENDMOL %0.005ND
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.95
SOPDELTA 13C C2-32.48
SOPDELTA 13C C3-28.42
SOPDELTA 13C iC4-31.09
SOPDelta 13C iC5-28.39
SOPDELTA 13C nC4-27.36
SOPDelta 13C nC5-26.98
SOPDELTA D C1-228
SOPETHANE9.41MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0176MOL %0.0025
SOPHYDROGENNDMOL %0.0025ND
SOPISOBUTANE0.622MOL %0.0001
SOPISOPENTANE0.389MOL %0.0001
SOPMETHANE82.47MOL %0.0002
SOPNITROGEN (N2)1.02MOL %0.01
SOPOXYGEN (O2)0.1MOL %0.01
SOPPENTANE0.321MOL %0.0001
SOPPROPANE4.19MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.692RATIO_AIR

 Sample ID:   666834     Sample Date:  02/05/2025     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 666834    ISOTECH ID: 956706
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0064MOL %0.005
SOPBRITISH THERMAL UNITS1207BTU
SOPBUTANE1.32MOL %0.0001
SOPC6+ (hexanes +)0.0244MOL %0.0001
SOPCARBON DIOXIDE2.5MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-46.9
SOPDELTA 13C C2-31.11
SOPDELTA 13C C3-27.48
SOPDELTA 13C CO22.73
SOPDELTA 13C iC4-30.53
SOPDelta 13C iC5-27.88
SOPDELTA 13C nC4-26.69
SOPDelta 13C nC5-26.13
SOPDELTA D C1-224.5
SOPETHANE11.58MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0101MOL %0.0025
SOPHYDROGEN0.0074MOL %0.0025
SOPISOBUTANE0.692MOL %0.0001
SOPISOPENTANE0.34MOL %0.0001
SOPMETHANE77.81MOL %0.0002
SOPNITROGEN (N2)0.63MOL %0.01
SOPOXYGEN (O2)0.11MOL %0.01
SOPPENTANE0.273MOL %0.0001
SOPPROPANE4.69MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.724RATIO_AIR