Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#294745 Information View DocsDoc View GISGIS
Sample Site ID294745
FacilityTypeOGProj Number
CountyBOULDER - 013LocationNWNE 10 1N69W
Elevation5083Lat/Long40.069875/-105.098831
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-013-06579Well Name:ALCORN 32-10
Well Status:PAOperator Name:CRESTONE PEAK RESOURCES OPERATING LLC
Location:NWNE  10 1N  69W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   612944     Sample Date:  12/13/2019     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 612944    ISOTECH ID: 747701
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0064MOL %0.005
SOPBRITISH THERMAL UNITS1321BTU
SOPBUTANE2.58MOL %0.0001
SOPC6+ (hexanes +)0.0988MOL %0.0001
SOPCARBON DIOXIDE1.73MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-48.8
SOPDELTA 13C C2-32.4
SOPDELTA 13C C3-28.5
SOPDELTA 13C CO21.1
SOPDELTA 13C iC4-31.3
SOPDelta 13C iC5-28.3
SOPDELTA 13C nC4-27.9
SOPDelta 13C nC5-27.5
SOPDELTA D C1-243
SOPETHANE13.66MOL %0.0001
SOPETHENE0.0003MOL %0.0001
SOPHelium0.0121MOL %0.005
SOPHYDROGEN0.396MOL %0.01
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE1.05MOL %0.0001
SOPISOPENTANE0.547MOL %0.0001
SOPMETHANE71.34MOL %0.0002
SOPNITROGEN (N2)0.63MOL %0.01
SOPOXYGEN (O2)0.12MOL %0.01
SOPPENTANE0.518MOL %0.0001
SOPPROPANE7.31MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.785RATIO_AIR

 Sample ID:   612945     Sample Date:  12/13/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 612945    ISOTECH ID: 747702
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0148MOL %0.005
SOPBRITISH THERMAL UNITS1119BTU
SOPBUTANE0.91MOL %0.0001
SOPC6+ (hexanes +)0.116MOL %0.0001
SOPCARBON DIOXIDE0.006MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-56
SOPDELTA 13C C2-34.3
SOPDELTA 13C C3-30.8
SOPDELTA 13C iC4-31.9
SOPDelta 13C iC5-28.8
SOPDELTA 13C nC4-29.1
SOPDelta 13C nC5-28.4
SOPDELTA D C1-226
SOPETHANE4.83MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0751MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.481MOL %0.0001
SOPISOPENTANE0.195MOL %0.0001
SOPMETHANE86.17MOL %0.0002
SOPNITROGEN (N2)3.26MOL %0.01
SOPOXYGEN (O2)0.11MOL %0.01
SOPPENTANE0.185MOL %0.0001
SOPPROPANE3.65MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.657RATIO_AIR

 Sample ID:   645297     Sample Date:  11/22/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 645297    Dolan Integration Group ID: DIG-030352
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1048BTU/cuft
SOPBUTANE0.417MOL %0.005
SOPC6+ (hexanes +)0.068MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-52.6per mil
SOPDELTA 13C C2-35per mil
SOPDELTA 13C C3-33.7per mil
SOPDELTA D C1-226per mil
SOPETHANE3.397MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.09MOL %0.005
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.227MOL %0.005
SOPISOPENTANE0.09MOL %0.005
SOPMETHANE89.815MOL %0.005
SOPNITROGEN (N2)3.847MOL %0.005
SOPOXYGEN + ARGON0.039MOL %0.005
SOPPENTANE0.09MOL %0.005
SOPPROPANE1.918MOL %0.005
SOPSPECIFIC GRAVITY0.62No Unit

 Sample ID:   631022     Sample Date:  10/29/2021     Matrix:  GAS     Collection Point:  PRODEQP     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 631022    Dolan Integration Group ID: DIG-026700
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1075BTU/cuft
SOPBUTANE0.546MOL %0.005
SOPC6+ (hexanes +)0.438MOL %0.005
SOPCARBON DIOXIDE0.031MOL %0.005
SOPDELTA 13C C1-57per mil
SOPDELTA 13C C2-33.5per mil
SOPDELTA 13C C3-30.4per mil
SOPDELTA 13C iC4-32.5per mil
SOPDELTA 13C nC4-29.4per mil
SOPDELTA D C1-224per mil
SOPETHANE3.508MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.112MOL %0.005
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.299MOL %0.005
SOPISOPENTANE0.158MOL %0.005
SOPMETHANE88.469MOL %0.005
SOPNITROGEN (N2)3.953MOL %0.005
SOPOXYGEN + ARGON0.072MOL %0.005
SOPPENTANE0.19MOL %0.005
SOPPROPANE2.224MOL %0.005
SOPSPECIFIC GRAVITY0.639No Unit

 Sample ID:   631021     Sample Date:  10/29/2021     Matrix:  GAS     Collection Point:  PRODEQP     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 631021    Dolan Integration Group ID: DIG-026701
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1287BTU/cuft
SOPBUTANE2.227MOL %0.005
SOPC6+ (hexanes +)0.41MOL %0.005
SOPCARBON DIOXIDE1.774MOL %0.005
SOPDELTA 13C C1-48.2per mil
SOPDELTA 13C C2-32per mil
SOPDELTA 13C C3-28.4per mil
SOPDELTA 13C CO21.5per mil
SOPDELTA 13C iC4-31.1per mil
SOPDelta 13C iC5-28per mil
SOPDELTA 13C nC4-28.4per mil
SOPDelta 13C nC5-28.1per mil
SOPDELTA D C1-245per mil
SOPETHANE11.865MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.322MOL %0.005
SOPISOBUTANE0.889MOL %0.005
SOPISOPENTANE0.58MOL %0.005
SOPMETHANE74.655MOL %0.005
SOPNITROGEN (N2)0.677MOL %0.005
SOPOXYGEN + ARGON0.056MOL %0.005
SOPPENTANE0.64MOL %0.005
SOPPROPANE5.904MOL %0.005
SOPSPECIFIC GRAVITY0.768No Unit

 Sample ID:   619897     Sample Date:  08/18/2020     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 619897    ISOTECH ID: 769374
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.391MOL %0.005
SOPBRITISH THERMAL UNITS634BTU
SOPBUTANE0.306MOL %0.0001
SOPC6+ (hexanes +)0.068MOL %0.0001
SOPCARBON DIOXIDE0.061MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-56.2
SOPDELTA 13C C2-34.4
SOPDELTA 13C C3-30.7
SOPDELTA 13C CO2-5.9
SOPDELTA 13C iC4-31.7
SOPDelta 13C iC5-28.3
SOPDELTA 13C nC4-29
SOPDelta 13C nC5-28.1
SOPDELTA D C1-222
SOPETHANE2.03MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0598MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.181MOL %0.0001
SOPISOPENTANE0.0676MOL %0.0001
SOPMETHANE53.31MOL %0.0002
SOPNITROGEN (N2)32.97MOL %0.01
SOPOXYGEN (O2)9.16MOL %0.01
SOPPENTANE0.0624MOL %0.0001
SOPPROPANE1.33MOL %0.0001
SOPPROPENENDMOL %0.0001ND
SOPSPECIFIC GRAVITY0.778RATIO_AIR

 Sample ID:   666007     Sample Date:  01/30/2025     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 666007    Dolan Integration Group ID: DIG-039017
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1025BTU/cuft
SOPBUTANE0.329MOL %0.005
SOPC6+ (hexanes +)0.019MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-56.4per mil
SOPDELTA 13C C2-34.1per mil
SOPDELTA 13C C3-30.4per mil
SOPDELTA 13C iC4-31.4per mil
SOPDELTA 13C nC4-28.5per mil
SOPDELTA D C1-226per mil
SOPETHANE3.151MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.081MOL %0.005
SOPHYDROGENNDMOL %0.005ND
SOPISOBUTANE0.209MOL %0.005
SOPISOPENTANE0.061MOL %0.005
SOPMETHANE89.146MOL %0.005
SOPNITROGEN (N2)4.964MOL %0.005
SOPOXYGEN + ARGON0.205MOL %0.005
SOPPENTANE0.054MOL %0.005
SOPPROPANE1.781MOL %0.005
SOPSPECIFIC GRAVITY0.618No Unit