Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#279203 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID279203
FacilityTypeOGProj Number
CountyGARFIELD - 045LocationNWNE 4 8S96W
Elevation5101Lat/Long39.385/-108.11132
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-045-11013Well Name:KEINATH 33-15 (OB4)
Well Status:SIOperator Name:QB ENERGY OPERATING LLC
Location:NWNE  4  8S  96W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   531714     Sample Date:  12/20/2009     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531714    Questar Applied Technology Services ID: Casing
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0028MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0034MOL %
SOP2,3-DIMETHYLBUTANE0.0062MOL %
SOP2-METHYLPENTANE0.0193MOL %
SOP26# Gasoline GPM0.193475gal/MCF
SOP3-METHYLPENTANE0.0101MOL %
SOPAvg Molecular Weight17.805gm/mole
SOPBase Mol Percent99.821%v/v
SOPBENZENE0.0024MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1070.6BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1088.3BTU
SOPBUTANE0.2793MOL %
SOPButane GPM0.172491gal/MCF
SOPCARBON DIOXIDE0.8109MOL %
SOPCYCLOHEXANE0.0085MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0001MOL %
SOPETHANE5.1902MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9975NA
SOPGasoline GPM0.105566gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0446MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.2593MOL %
SOPISOPENTANE0.0987MOL %
SOPM-+P-XYLENE0.0002MOL %
SOPMETHANE91.6947MOL %
SOPMETHYL CYCLOHEXANE0.0093MOL %
SOPN-HEXANE0.0229MOL %
SOPNITROGEN (N2)0.0804MOL %
SOPNONANE0.0003MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0.0025MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.0724MOL %
SOPPROPANE1.4019MOL %
SOPPropane GPM0.385423gal/MCF
SOPSample Pressure980PSIG
SOPSample Temperature39degrees F
SOPSPECIFIC GRAVITY0.6162RATIO_AIR
SOPTOLUENE0.0019MOL %
SOPTotal non gas liquids GPM0.663532gal/MCF

 Sample ID:   531712     Sample Date:  07/28/2009     Matrix:  GAS     Collection Point:  INTCase     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531712    Questar Applied Technology Services ID: 300106022
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0035MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0036MOL %
SOP2,3-DIMETHYLBUTANE0.0091MOL %
SOP2-METHYLPENTANE0.0263MOL %
SOP26# Gasoline GPM0.238933gal/MCF
SOP3-METHYLPENTANE0.014MOL %
SOPAvg Molecular Weight17.93gm/mole
SOPBase Mol Percent98.919%v/v
SOPBENZENE0.0037MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1080.7BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1098.6BTU
SOPBUTANE0.3092MOL %
SOPButane GPM0.192798gal/MCF
SOPCARBON DIOXIDE0.6717MOL %
SOPCYCLOHEXANE0.0141MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0MOL %
SOPETHANE5.4217MOL %
SOPETHYLBENZENE0.0002MOL %
SOPGas Compressibility0.9975NA
SOPGasoline GPM0.141298gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0804MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.2927MOL %
SOPISOPENTANE0.1155MOL %
SOPM-+P-XYLENE0.0011MOL %
SOPMETHANE91.3184MOL %
SOPMETHYL CYCLOHEXANE0.0183MOL %
SOPN-HEXANE0.0329MOL %
SOPNITROGEN (N2)0.0725MOL %
SOPNONANE0.0026MOL %
SOPo-XYLENE0.0002MOL %
SOPOCTANE, MIXED ISOMERS0.0069MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.0872MOL %
SOPPROPANE1.5318MOL %
SOPPropane GPM0.421137gal/MCF
SOPSample Pressure900PSIG
SOPSample Temperature103degrees F
SOPSPECIFIC GRAVITY0.6205RATIO_AIR
SOPTOLUENE0.0041MOL %
SOPTotal non gas liquids GPM0.755604gal/MCF

 Sample ID:   531716     Sample Date:  07/10/2009     Matrix:  GAS     Collection Point:  BDH     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531716    Questar Applied Technology Services ID: 300106022
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0036MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0038MOL %
SOP2,3-DIMETHYLBUTANE0.0078MOL %
SOP2-METHYLPENTANE0.025MOL %
SOP26# Gasoline GPM0.222355gal/MCF
SOP3-METHYLPENTANE0.0132MOL %
SOPAvg Molecular Weight17.662gm/mole
SOPBase Mol Percent100.853%v/v
SOPBENZENE0.0006MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1083.1BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1101BTU
SOPBUTANE0.2969MOL %
SOPButane GPM0.187134gal/MCF
SOPCARBON DIOXIDE0.0009MOL %
SOPCYCLOHEXANE0.0091MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0003MOL %
SOPETHANE5.2008MOL %
SOPETHYLBENZENE0MOL %
SOPGas Compressibility0.9975NA
SOPGasoline GPM0.12896gal/MCF
SOPHEPTANES, MIXED ISOMERS0.0598MOL %
SOPHYDROGEN SULFIDENDMOL %ND
SOPISOBUTANE0.2872MOL %
SOPISOPENTANE0.1125MOL %
SOPM-+P-XYLENE0MOL %
SOPMETHANE92.3244MOL %
SOPMETHYL CYCLOHEXANE0.0126MOL %
SOPN-HEXANE0.0299MOL %
SOPNITROGEN (N2)0.0775MOL %
SOPNONANE0.0008MOL %
SOPo-XYLENE0MOL %
SOPOCTANE, MIXED ISOMERS0.0083MOL %
SOPOXYGEN (O2)NDMOL %ND
SOPPENTANE0.0821MOL %
SOPPROPANE1.4652MOL %
SOPPropane GPM0.402826gal/MCF
SOPSample Pressure100PSIG
SOPSample Temperature97degrees F
SOPSPECIFIC GRAVITY0.6112RATIO_AIR
SOPTOLUENE0.0007MOL %
SOPTotal non gas liquids GPM0.718921gal/MCF

 Sample ID:   531710     Sample Date:  04/12/2010     Matrix:  GAS     Collection Point:  BDH     Type:  PROD     Lab:  Questar Applied Technology Services

Sample Results for Sample # 531710    Questar Applied Technology Services ID: ML 300106022
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOP2,2-DIMETHYLBUTANE0.0031MOL %
SOP2,2-DIMETHYLPROPANE (neopentane)0.0028MOL %
SOP2,3-DIMETHYLBUTANE0.0077MOL %
SOP2-METHYLPENTANE0.0227MOL %
SOP26# Gasoline GPM0.225459gal/MCF
SOP3-METHYLPENTANE0.0126MOL %
SOPAvg Molecular Weight17.467gm/mole
SOPBase Mol Percent99.431%v/v
SOPBENZENE0.0051MOL %
SOPBRITISH THERMAL UNITS - SATURATED BASIS1071.7BTU
SOPBRITISH THERMAL UNITS- DRY BASIS1089.4BTU
SOPBUTANE0.2179MOL %
SOPButane GPM0.137423gal/MCF
SOPCARBON DIOXIDE0.0011MOL %
SOPCYCLOHEXANE0.0196MOL %
SOPCYCLOPENTANE0MOL %
SOPDECANES +0.0003MOL %
SOPETHANE4.2509MOL %
SOPETHYLBENZENE0.0003MOL %
SOPGas Compressibility0.9976NA
SOPGasoline GPM0.155184gal/MCF
SOPHEPTANES, MIXED ISOMERS0.1539MOL %
SOPHYDROGEN SULFIDE0MOL %
SOPISOBUTANE0.2111MOL %
SOPISOPENTANE0.0867MOL %
SOPM-+P-XYLENE0.002MOL %
SOPMETHANE93.6538MOL %
SOPMETHYL CYCLOHEXANE0.0595MOL %
SOPN-HEXANE0.0306MOL %
SOPNITROGEN (N2)0.1141MOL %
SOPNONANE0.0108MOL %
SOPo-XYLENE0.0002MOL %
SOPOCTANE, MIXED ISOMERS0.0506MOL %
SOPOXYGEN (O2)0MOL %
SOPPENTANE0.0654MOL %
SOPPROPANE1.1039MOL %
SOPPropane GPM0.302538gal/MCF
SOPSample Pressure100PSIG
SOPSample Temperature34degrees F
SOPSPECIFIC GRAVITY0.6043RATIO_AIR
SOPTOLUENE0.0086MOL %
SOPTotal non gas liquids GPM0.5969gal/MCF