Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#246568 Information View DocsDoc View GISGIS
Sample Site ID246568
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSE 33 3N66W
Elevation4937Lat/Long40.176089/-104.779775
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-14365Well Name:HSR - STEER 15-33A
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SWSE  33 3N  66W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   601858     Sample Date:  08/20/2018     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 601858    Dolan Integration Group ID: DIG-015771
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS405BTU/cuft
SOPBUTANE1.02MOL %0.005
SOPC6+ (hexanes +)0.48MOL %0.005
SOPCARBON DIOXIDE0.11MOL %0.005
SOPDELTA 13C C1-49per mil
SOPDELTA 13C C2-31.1per mil
SOPDELTA 13C C3-26.7per mil
SOPDELTA 13C iC4-30.1per mil
SOPDelta 13C iC5-26.9per mil
SOPDELTA 13C nC4-26.3per mil
SOPDelta 13C nC5-26.2per mil
SOPDELTA D C1-249per mil
SOPETHANE2.64MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.01MOL %0.005
SOPHYDROGEN0.02MOL %0.005
SOPISOBUTANE0.29MOL %0.005
SOPISOPENTANE0.49MOL %0.005
SOPMETHANE22.73MOL %0.005
SOPNITROGEN (N2)53.94MOL %0.005
SOPOXYGEN + ARGON16.87MOL %0.005
SOPPENTANE0.49MOL %0.005
SOPPROPANE0.91MOL %0.005
SOPSPECIFIC GRAVITY0.941RATIO_AIR

 Sample ID:   601859     Sample Date:  08/20/2018     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 601859    Dolan Integration Group ID: DIG-015770
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1105BTU/cuft
SOPBUTANE1.32MOL %0.005
SOPC6+ (hexanes +)0.2MOL %0.005
SOPCARBON DIOXIDE1.49MOL %0.005
SOPDELTA 13C C1-46.5per mil
SOPDELTA 13C C2-29.6per mil
SOPDELTA 13C C3-25.8per mil
SOPDELTA 13C CO25.8per mil
SOPDELTA 13C iC4-28.6per mil
SOPDelta 13C iC5-26.4per mil
SOPDELTA 13C nC4-25.3per mil
SOPDelta 13C nC5-25.4per mil
SOPDELTA D C1-233per mil
SOPETHANE11.66MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.01MOL %0.005
SOPHYDROGEN0.01MOL %0.005
SOPISOBUTANE0.74MOL %0.005
SOPISOPENTANE0.36MOL %0.005
SOPMETHANE67.9MOL %0.005
SOPNITROGEN (N2)10.13MOL %0.005
SOPOXYGEN + ARGON1.49MOL %0.005
SOPPENTANE0.25MOL %0.005
SOPPROPANE4.45MOL %0.005
SOPSPECIFIC GRAVITY0.742RATIO_AIR

 Sample ID:   601861     Sample Date:  08/20/2008     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 601861    Weatherford Laboratories  ID: 6126925830
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane1662ppm
G02G1,1-dimethylcyclopentane1583ppm
G02G1,2,3-trimethylcyclopentane1116ppm
G02G1,2,4-trimethylcyclopentane1453ppm
G02G2,2,3-trimethylbutane79ppm
G02G2,2-DIMETHYLBUTANE247ppm
G02G2,2-dimethylpentane452ppm
G02G2,3-DIMETHYLBUTANE1254ppm
G02G2,3-dimethylpentane255ppm
G02G2,3-dimethylpentane1843ppm
G02G2,4-dimethylpentane1199ppm
G02G2-METHYLPENTANE8911ppm
G02G3-ethylpentane402ppm
G02G3-methylhexane7042ppm
G02G3-methylhexane7063ppm
G02G3-METHYLPENTANE5502ppm
G02GBENZENE686ppm
G02GBUTANE3162ppm
G02Gcis-1,3-dimethylcyclopentane2081ppm
G02GCYCLOHEXANE7908ppm
G02GCYCLOPENTANE1139ppm
G02GDecane14529ppm
G02GETHYLBENZENE1298ppm
G02Gethylcyclopentane713ppm
G02GHEPTANES, MIXED ISOMERS19519ppm
G02GHEXANES17064ppm
G02Ghighly branched C25 isoprenoid262ppm
G02GISOBUTANE463ppm
G02GISOPENTANE7380ppm
G02Gisoprenoid C103128ppm
G02Gisoprenoid C113115ppm
G02Gisoprenoid C133100ppm
G02Gisoprenoid C142256ppm
G02Gisoprenoid C152652ppm
G02Gisoprenoid C163717ppm
G02Gisoprenoid C183291ppm
G02Gisoprenoid C92150ppm
G02Gm-XYLENE10373ppm
G02GMETHYL CYCLOHEXANE20795ppm
G02GMETHYLCYCLOPENTANE7075ppm
G02Gn-C1113890ppm
G02Gn-C1212132ppm
G02Gn-C1311322ppm
G02Gn-C1410484ppm
G02Gn-C159801ppm
G02Gn-C168525ppm
G02Gn-C177726ppm
G02Gn-C186566ppm
G02Gn-C195833ppm
G02Gn-C205385ppm
G02Gn-C214588ppm
G02Gn-C224110ppm
G02Gn-C233669ppm
G02Gn-C243199ppm
G02Gn-C252749ppm
G02Gn-C262438ppm
G02Gn-C271904ppm
G02Gn-C281587ppm
G02Gn-C291439ppm
G02Gn-C301138ppm
G02Gn-C31861ppm
G02Gn-c32620ppm
G02Gn-C33506ppm
G02Gn-C34371ppm
G02Gn-C35237ppm
G02Gn-C3697ppm
G02Gn-C3781ppm
G02Gn-C3851ppm
G02Gn-C3938ppm
G02Gn-C4025ppm
G02Gn-C410ppm
G02Gn-octane19441ppm
G02GNormal Alkane C916296ppm
G02Go-XYLENE3662ppm
G02Gp-XYLENE3652ppm
G02GPENTANE12057ppm
G02GPHENANTHRENE199ppm
G02Gphytane2162ppm
G02Gpristane3657ppm
G02GPropyl-benzene1231ppm
G02GTOLUENE7887ppm
G02Gtrans-1,2-dimethylcyclopentane2986ppm
G02Gtrans-1,3-dimethylcyclopentane1946ppm