COGIS - Environmental Sample Site Information

 
#296726 Information View DocsDoc View GISGIS
Sample Site ID296726
FacilityTypeOGProj Number
CountyWELD - 123LocationSESE 6 1N68W
Elevation5019Lat/Long40.074644/-105.039408
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-26885Well Name:BULTHAUP 16-6
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:SESE  6  1N  68W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   639020     Sample Date:  5/9/2022     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  ISOTECH

Sample Results for Sample # 639020    ISOTECH ID: 828585
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGON0.0412MOL %0.005
SOPBRITISH THERMAL UNITS981BTU
SOPBUTANE0.579MOL %0.0001
SOPC6+ (hexanes +)0.077MOL %0.0001
SOPCARBON DIOXIDE0.005MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-59.89
SOPDELTA 13C C2-32.65
SOPDELTA 13C C3-28.94
SOPDELTA 13C iC4-31.56
SOPDelta 13C iC5-28.58
SOPDELTA 13C nC4-27.88
SOPDelta 13C nC5-27.48
SOPDELTA D C1-262.2
SOPETHANE3.82MOL %0.0001
SOPETHENE0.0002MOL %0.0001
SOPHelium0.363MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.343MOL %0.0001
SOPISOPENTANE0.171MOL %0.0001
SOPMETHANE80.86MOL %0.0002
SOPNITROGEN (N2)11.71MOL %0.01
SOPOXYGEN (O2)0.042MOL %0.01
SOPPENTANE0.143MOL %0.0001
SOPPROPANE1.85MOL %0.0001
SOPPROPENE0.0004MOL %0.0001
SOPSPECIFIC GRAVITY0.659RATIO_AIR

 Sample ID:   639019     Sample Date:  5/9/2022     Matrix:  WATER     Collection Point:  TB     Type:  TB     Lab:  Accutest

Sample Results for Sample # 639019    Accutest ID: DA44815-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SW8015TVPH - Gasoline Range Organics0.245mg/L0.2
SW8260BENZENENDug/L0.5U
SW8260ETHYLBENZENENDug/L1U
SW8260TOLUENENDug/L1U
SW8260TOTAL XYLENESNDug/L1U

 Sample ID:   639018     Sample Date:  5/9/2022     Matrix:  WATER     Collection Point:  BDH     Type:  BDH     Lab:  Accutest

Sample Results for Sample # 639018    Accutest ID: DA44813-1
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
E200.8BARIUM3.43mg/L0.002
E200.8BORON0.269mg/L0.04
E200.8CALCIUM3.9mg/L0.4
E200.8IRON0.122mg/L0.04
E200.8MAGNESIUM0.429mg/L0.2
E200.8MANGANESE0.0041mg/L0.002
E200.8POTASSIUM1.89mg/L0.4
E200.8SELENIUMNDmg/L0.0004U
E200.8SODIUM514mg/L25
E200.8STRONTIUM0.301mg/L0.02
E300.0BROMIDE4.5mg/L0.1
E300.0CHLORIDE494mg/L13
E300.0FLUORIDE3.3mg/L2.5
E300.0NITRATENDmg/L0.02U
E300.0NITRITENDmg/L0.1U
E300.0SULFATENDmg/L1U
FIELDpH, FIELD10.1SU
FIELDSPECIFIC CONDUCTIVITY, FIELD2260UMHOS/CM0.5
FIELDTEMPERATURE, FIELD16.1degrees C
RSK175ETHANE1.71mg/L0.08
RSK175METHANE8.74mg/L0.04B
RSK175PROPANE0.966mg/L0.11
SM1030CATION - ANION BALANCE4.5%
SM2320BBICARBONATE ALKALINITY as CACO3125mg/L5
SM2320BCARBONATE ALKALINITY AS CACO3200mg/L5
SM2320BTOTAL ALKALINITY AS CACO3325mg/L5
SM2510BSPECIFIC CONDUCTIVITY2410UMHOS/CM1
SM2540CTOTAL DISSOLVED SOLIDS1510mg/L10
SM4500-H+ BpH, FIELD9.96SU
SW8015TEPH DIESEL RANGE ORGANICS30.5mg/L0.024
SW8015TVPH - Gasoline Range Organics0.901mg/L0.2
SW8260BENZENE98.6ug/L0.5
SW8260ETHYLBENZENE15.3ug/L1
SW8260TOLUENE11.4ug/L1
SW8260TOTAL XYLENES82.5ug/L1

 Sample ID:   639021     Sample Date:  5/9/2022     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  ISOTECH

Sample Results for Sample # 639021    ISOTECH ID: 828584
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPARGONNDMOL %0.005ND
SOPBRITISH THERMAL UNITS1270BTU
SOPBUTANE1.78MOL %0.0001
SOPC6+ (hexanes +)0.131MOL %0.0001
SOPCARBON DIOXIDE1.46MOL %0.005
SOPCARBON MONOXIDENDMOL %0.01ND
SOPDELTA 13C C1-47.8
SOPDELTA 13C C2-32.4
SOPDELTA 13C C3-28.82
SOPDELTA 13C CO22.26
SOPDELTA 13C iC4-31.51
SOPDelta 13C iC5-28.52
SOPDELTA 13C nC4-27.92
SOPDelta 13C nC5-27.58
SOPDELTA D C1-240.2
SOPETHANE12.73MOL %0.0001
SOPETHENENDMOL %0.0001ND
SOPHelium0.0139MOL %0.005
SOPHYDROGENNDMOL %0.01ND
SOPHYDROGEN SULFIDENDMOL %0ND
SOPISOBUTANE0.775MOL %0.0001
SOPISOPENTANE0.405MOL %0.0001
SOPMETHANE76MOL %0.0002
SOPNITROGEN (N2)0.4MOL %0.01
SOPOXYGEN (O2)0.015MOL %0.01
SOPPENTANE0.407MOL %0.0001
SOPPROPANE5.88MOL %0.0001
SOPPROPENE0.0013MOL %0.0001
SOPSPECIFIC GRAVITY0.744RATIO_AIR