Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#416452 Information View DocsDocView GIS GIS View Old GISOld GIS
Sample Site ID416452
FacilityTypeOGProj Number
CountyWELD - 123LocationSWSE 32 5N65W
Elevation4668Lat/Long40.352038/-104.682863
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-31381Well Name:STROHAUER F 32-22D
Well Status:PAOperator Name:PDC ENERGY INC
Location:SWSE  32 5N  65W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   631669     Sample Date:  11/30/2021     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 631669    Dolan Integration Group ID: DIG-026790
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1158BTU/cuft
SOPBUTANE0.99MOL %0.005
SOPC6+ (hexanes +)0.177MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-49per mil
SOPDELTA 13C C2-33.3per mil
SOPDELTA 13C C3-28.7per mil
SOPDELTA 13C iC4-31.9per mil
SOPDelta 13C iC5-28.3per mil
SOPDELTA 13C nC4-28.2per mil
SOPDelta 13C nC5-28per mil
SOPDELTA D C1-238per mil
SOPETHANE8.908MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.283MOL %0.005
SOPISOBUTANE0.544MOL %0.005
SOPISOPENTANE0.25MOL %0.005
SOPMETHANE81.15MOL %0.005
SOPNITROGEN (N2)2.989MOL %0.005
SOPOXYGEN + ARGON0.495MOL %0.005
SOPPENTANE0.213MOL %0.005
SOPPROPANE4MOL %0.005
SOPSPECIFIC GRAVITY0.687No Unit

 Sample ID:   631670     Sample Date:  11/30/2021     Matrix:  GAS     Collection Point:  PRDC     Type:  PCS     Lab:  Dolan Integration Group

Sample Results for Sample # 631670    Dolan Integration Group ID: DIG-026791
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1210BTU/cuft
SOPBUTANE1.431MOL %0.005
SOPC6+ (hexanes +)0.045MOL %0.005
SOPCARBON DIOXIDE2.641MOL %0.005
SOPDELTA 13C C1-45per mil
SOPDELTA 13C C2-28.9per mil
SOPDELTA 13C C3-26per mil
SOPDELTA 13C CO22.9per mil
SOPDELTA 13C iC4-29.9per mil
SOPDelta 13C iC5-28per mil
SOPDELTA 13C nC4-26.1per mil
SOPDelta 13C nC5-27.3per mil
SOPDELTA D C1-226per mil
SOPETHANE12.247MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.039MOL %0.005
SOPISOBUTANE0.725MOL %0.005
SOPISOPENTANE0.33MOL %0.005
SOPMETHANE76.893MOL %0.005
SOPNITROGEN (N2)0.57MOL %0.005
SOPOXYGEN + ARGON0.09MOL %0.005
SOPPENTANE0.304MOL %0.005
SOPPROPANE4.682MOL %0.005
SOPSPECIFIC GRAVITY0.732No Unit

 Sample ID:   613124     Sample Date:  11/13/2019     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 613124    Dolan Integration Group ID: DIG-020967
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1151BTU/cuft
SOPBUTANE1.12MOL %0.005
SOPC6+ (hexanes +)0.56MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-48.4per mil
SOPDELTA 13C C2-33.5per mil
SOPDELTA 13C C3-29.1per mil
SOPDELTA 13C iC4-33.3per mil
SOPDELTA 13C nC4-28.3per mil
SOPDelta 13C nC5-28per mil
SOPDELTA D C1-235per mil
SOPETHANE7.5MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHeliumNDMOL %0.005ND
SOPHYDROGEN0.25MOL %0.005
SOPISOBUTANE0.58MOL %0.005
SOPISOPENTANE0.31MOL %0.005
SOPMETHANE80.25MOL %0.005
SOPNITROGEN (N2)4.39MOL %0.005
SOPOXYGEN + ARGON0.82MOL %0.005
SOPPENTANE0.28MOL %0.005
SOPPROPANE3.94MOL %0.005
SOPSPECIFIC GRAVITY0.701No Unit

 Sample ID:   613126     Sample Date:  11/13/2019     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Weatherford Laboratories

Sample Results for Sample # 613126    Weatherford Laboratories  ID: G9190976
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane698ppm
G02G1,1-dimethylcyclopentane531ppm
G02G1,2,3-trimethylcyclopentane485ppm
G02G1,2,4-trimethylcyclopentane595ppm
G02G2,2,3-trimethylbutane57ppm
G02G2,2-DIMETHYLBUTANE90ppm
G02G2,2-dimethylpentane219ppm
G02G2,3-DIMETHYLBUTANE410ppm
G02G2,3-dimethylpentane126ppm
G02G2,3-dimethylpentane632ppm
G02G2,4-dimethylpentane443ppm
G02G2-METHYLPENTANE2408ppm
G02G3-ethylpentane170ppm
G02G3-methylhexane2826ppm
G02G3-methylhexane2865ppm
G02G3-METHYLPENTANE1604ppm
G02GBENZENE161ppm
G02GBUTANEppm
G02Gcis-1,3-dimethylcyclopentane715ppm
G02GCYCLOHEXANE3907ppm
G02GCYCLOPENTANE280ppm
G02GDecane25534ppm
G02GETHYLBENZENE1248ppm
G02Gethylcyclopentane306ppm
G02GHEPTANES, MIXED ISOMERS9325ppm
G02GHEXANES5144ppm
G02Ghighly branched C25 isoprenoid234ppm
G02GISOBUTANEppm
G02GISOPENTANE1528ppm
G02Gisoprenoid C105434ppm
G02Gisoprenoid C115417ppm
G02Gisoprenoid C135068ppm
G02Gisoprenoid C143518ppm
G02Gisoprenoid C153464ppm
G02Gisoprenoid C164861ppm
G02Gisoprenoid C183597ppm
G02Gisoprenoid C91623ppm
G02Gm-XYLENE14593ppm
G02GMETHYL CYCLOHEXANE9256ppm
G02GMETHYLCYCLOPENTANE2827ppm
G02Gn-C1123664ppm
G02Gn-C1219753ppm
G02Gn-C1316990ppm
G02Gn-C1414144ppm
G02Gn-C1512404ppm
G02Gn-C169992ppm
G02Gn-C178321ppm
G02Gn-C186693ppm
G02Gn-C195497ppm
G02Gn-C204758ppm
G02Gn-C213680ppm
G02Gn-C223131ppm
G02Gn-C232527ppm
G02Gn-C242111ppm
G02Gn-C251656ppm
G02Gn-C261377ppm
G02Gn-C27934ppm
G02Gn-C28726ppm
G02Gn-C29571ppm
G02Gn-C30411ppm
G02Gn-C31295ppm
G02Gn-c32200ppm
G02Gn-C33164ppm
G02Gn-C34133ppm
G02Gn-C3597ppm
G02Gn-C3645ppm
G02Gn-C3746ppm
G02Gn-C3828ppm
G02Gn-C390ppm
G02Gn-C400ppm
G02Gn-C410ppm
G02Gn-octane20740ppm
G02GNormal Alkane C926977ppm
G02Go-XYLENE4519ppm
G02Gp-XYLENE4005ppm
G02GPENTANE2260ppm
G02GPHENANTHRENE175ppm
G02Gphytane2371ppm
G02Gpristane3779ppm
G02GPropyl-benzene1653ppm
G02GTOLUENE4312ppm
G02Gtrans-1,2-dimethylcyclopentane1048ppm
G02Gtrans-1,3-dimethylcyclopentane667ppm