Sample ID: 628653 Sample Date: 07/14/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 628653 ISOTECH ID: 798161 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 904 | BTU | | | | SOP | BUTANE | 0.529 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0637 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.87 | ‰ | | | | SOP | DELTA 13C C2 | -32.17 | ‰ | | | | SOP | DELTA 13C C3 | -29.42 | ‰ | | | | SOP | DELTA 13C iC4 | -32 | ‰ | | | | SOP | DELTA 13C nC4 | -28.4 | ‰ | | | | SOP | DELTA D C1 | -228.9 | ‰ | | | | SOP | ETHANE | 10.92 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0021 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.81 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.217 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0405 | MOL % | 0.0001 | | | SOP | METHANE | 57.02 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 20.39 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 6.79 | MOL % | 0.01 | | | SOP | PENTANE | 0.0347 | MOL % | 0.0001 | | | SOP | PROPANE | 3.99 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0032 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.781 | RATIO_AIR | | |
Sample ID: 628650 Sample Date: 07/14/2021 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 628650 ISOTECH ID: 798174 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1453 | BTU | | | | SOP | BUTANE | 4.33 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.474 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.29 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.6 | ‰ | | | | SOP | DELTA 13C C2 | -31.8 | ‰ | | | | SOP | DELTA 13C C3 | -28.3 | ‰ | | | | SOP | DELTA 13C CO2 | 3.7 | ‰ | | | | SOP | DELTA 13C iC4 | -31.6 | ‰ | | | | SOP | Delta 13C iC5 | -28.5 | ‰ | | | | SOP | DELTA 13C nC4 | -27.5 | ‰ | | | | SOP | Delta 13C nC5 | -27.4 | ‰ | | | | SOP | DELTA D C1 | -234 | ‰ | | | | SOP | ETHANE | 12.69 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0007 | MOL % | 0.0001 | | | SOP | Helium | 0.0077 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.0668 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 1.77 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 1.36 | MOL % | 0.0001 | | | SOP | METHANE | 67.19 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.3 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | ND | MOL % | 0.01 | ND | | SOP | PENTANE | 1.57 | MOL % | 0.0001 | | | SOP | PROPANE | 7.95 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.872 | RATIO_AIR | | |
Sample ID: 628654 Sample Date: 07/14/2021 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 628654 ISOTECH ID: 798161 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | mg/L | 0.01 | ND | | SOP | ETHANE | 4.9 | mg/L | 0.0002 | | | SOP | METHANE | 13 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 7.1 | mg/L | 0.02 | | | SOP | PROPANE | 2.5 | mg/L | 0.0003 | |
Sample ID: 628651 Sample Date: 07/14/2021 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 628651 Accutest ID: DA35912-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 628652 Sample Date: 07/14/2021 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 628652 Accutest ID: DA35911-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 0.61 | mg/L | 0.05 | | | E200.7 | CALCIUM | 0.447 | mg/L | 0.4 | | | E200.7 | IRON | 0.484 | mg/L | 0.02 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | 0.0056 | mg/L | 0.005 | | | E200.7 | POTASSIUM | 54.9 | mg/L | 1 | | | E200.7 | SODIUM | 600 | mg/L | 0.4 | | | E200.7 | STRONTIUM | 0.0062 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0696 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.0018 | mg/L | 0.0008 | | | E300.0 | BROMIDE | 0.34 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 169 | mg/L | 25 | | | E300.0 | FLUORIDE | 1.2 | mg/L | 0.5 | | | E300.0 | NITRATE | ND | mg/L | 0.5 | U | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.2 | U | | E300.0 | SULFATE | 349 | mg/L | 25 | | | FIELD | pH, FIELD | 11.6 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 7100 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 26.4 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 1.4 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 720 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 810 | mg/L | 5 | | | SW8015 | TEPH DIESEL RANGE ORGANICS | 33 | mg/L | 12 | | | SW8015 | TVPH - Gasoline Range Organics | 9.35 | mg/L | 1.3 | | | SW8260 | BENZENE | 16.6 | ug/L | 20 | J | | SW8260 | ETHYLBENZENE | 23.4 | ug/L | 20 | | | SW8260 | M-+P-XYLENE | 142 | ug/L | 20 | | | SW8260 | o-XYLENE | 351 | ug/L | 20 | | | SW8260 | TOLUENE | 67.2 | ug/L | 20 | | | SW8260 | TOTAL XYLENES | 493 | ug/L | 20 | |
Sample ID: 636337 Sample Date: 03/14/2022 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 636337 ISOTECH ID: 821601 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.147 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 1043 | BTU | | | | SOP | BUTANE | 0.904 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.059 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.022 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -49.8 | ‰ | | | | SOP | DELTA 13C C2 | -33.2 | ‰ | | | | SOP | DELTA 13C C3 | -29.7 | ‰ | | | | SOP | DELTA 13C iC4 | -31.6 | ‰ | | | | SOP | Delta 13C iC5 | -28.8 | ‰ | | | | SOP | DELTA 13C nC4 | -28.6 | ‰ | | | | SOP | Delta 13C nC5 | -28.3 | ‰ | | | | SOP | DELTA D C1 | -244 | ‰ | | | | SOP | ETHANE | 9.54 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0009 | MOL % | 0.0001 | | | SOP | Helium | 0.0057 | MOL % | 0.005 | | | SOP | HYDROGEN | 1.94 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.418 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.149 | MOL % | 0.0001 | | | SOP | METHANE | 68.59 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 11.16 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 2.44 | MOL % | 0.01 | | | SOP | PENTANE | 0.142 | MOL % | 0.0001 | | | SOP | PROPANE | 4.48 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0012 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.721 | RATIO_AIR | | |
Sample ID: 636338 Sample Date: 03/14/2022 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 636338 ISOTECH ID: 821600 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1314 | BTU | | | | SOP | BUTANE | 2.19 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.146 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.5 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -47.7 | ‰ | | | | SOP | DELTA 13C C2 | -32 | ‰ | | | | SOP | DELTA 13C C3 | -28.4 | ‰ | | | | SOP | DELTA 13C CO2 | 4.3 | ‰ | | | | SOP | DELTA 13C iC4 | -30.8 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -27.7 | ‰ | | | | SOP | Delta 13C nC5 | -27.3 | ‰ | | | | SOP | DELTA D C1 | -236 | ‰ | | | | SOP | ETHANE | 14.46 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0005 | MOL % | 0.0001 | | | SOP | Helium | 0.0085 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.16 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 1.03 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.494 | MOL % | 0.0001 | | | SOP | METHANE | 70.98 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.31 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 0.01 | MOL % | 0.01 | | | SOP | PENTANE | 0.498 | MOL % | 0.0001 | | | SOP | PROPANE | 7.21 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.788 | RATIO_AIR | | |
Sample ID: 659079 Sample Date: 03/05/2024 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 659079 ISOTECH ID: 913272 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.548 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 680 | BTU | | | | SOP | BUTANE | 0.532 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.0157 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | ND | MOL % | 0.005 | ND | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.76 | ‰ | | | | SOP | DELTA 13C C2 | -32.08 | ‰ | | | | SOP | DELTA 13C C3 | -29.36 | ‰ | | | | SOP | DELTA 13C iC4 | -31.6 | ‰ | | | | SOP | Delta 13C iC5 | -28.3 | ‰ | | | | SOP | DELTA 13C nC4 | -28.3 | ‰ | | | | SOP | Delta 13C nC5 | -27.1 | ‰ | | | | SOP | DELTA D C1 | -224.4 | ‰ | | | | SOP | ETHANE | 8.86 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0016 | MOL % | 0.0001 | | | SOP | HELIUM DILUTION FACTOR | 0.68 | NA | | | | SOP | HYDROGEN | ND | MOL % | 0.01 | ND | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.22 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0527 | MOL % | 0.0001 | | | SOP | METHANE | 39.81 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 36.76 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 9.6 | MOL % | 0.01 | | | SOP | PENTANE | 0.0461 | MOL % | 0.0001 | | | SOP | PROPANE | 3.55 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0025 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.854 | RATIO_AIR | | |
Sample ID: 659083 Sample Date: 03/05/2024 Matrix: GAS Collection Point: PRDC Type: PCS Lab: ISOTECH| Sample Results for Sample # 659083 ISOTECH ID: 914314 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | ND | MOL % | 0.005 | ND | | SOP | BRITISH THERMAL UNITS | 1277 | BTU | | | | SOP | BUTANE | 2.05 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.185 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 2.51 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -48.1 | ‰ | | | | SOP | DELTA 13C C2 | -31.8 | ‰ | | | | SOP | DELTA 13C C3 | -27.8 | ‰ | | | | SOP | DELTA 13C CO2 | 3.7 | ‰ | | | | SOP | DELTA 13C iC4 | -31 | ‰ | | | | SOP | Delta 13C iC5 | -28 | ‰ | | | | SOP | DELTA 13C nC4 | -27.4 | ‰ | | | | SOP | Delta 13C nC5 | -27.2 | ‰ | | | | SOP | DELTA D C1 | -237 | ‰ | | | | SOP | ETHANE | 12.88 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0001 | MOL % | 0.0001 | | | SOP | Helium | 0.0092 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.167 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.883 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.513 | MOL % | 0.0001 | | | SOP | METHANE | 74.16 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 0.33 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | ND | MOL % | 0.01 | ND | | SOP | PENTANE | 0.523 | MOL % | 0.0001 | | | SOP | PROPANE | 5.79 | MOL % | 0.0001 | | | SOP | PROPENE | ND | MOL % | 0.0001 | ND | | SOP | SPECIFIC GRAVITY | 0.764 | RATIO_AIR | | |
Sample ID: 659080 Sample Date: 03/05/2024 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 659080 ISOTECH ID: 913272 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.48 | mg/L | 0.01 | | | SOP | ETHANE | 6.3 | mg/L | 0.0002 | | | SOP | METHANE | 14 | mg/L | 0.0002 | | | SOP | NITROGEN (N2) | 20 | mg/L | 0.02 | | | SOP | PROPANE | 3.5 | mg/L | 0.0003 | |
Sample ID: 659082 Sample Date: 03/05/2024 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 659082 Accutest ID: DA62664-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
Sample ID: 659081 Sample Date: 03/05/2024 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 659081 Accutest ID: DA62669-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | FIELD | pH, FIELD | 12 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 3310 | umhos/cm | 0.5 | | | FIELD | TEMPERATURE, FIELD | 9.8 | degrees C | | | | SW8260 | BENZENE | 10.9 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 6.9 | ug/L | 10 | J | | SW8260 | M-+P-XYLENE | 44.6 | ug/L | 10 | | | SW8260 | o-XYLENE | 105 | ug/L | 10 | | | SW8260 | TOLUENE | 29.2 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 150 | ug/L | 10 | |
Sample ID: 616740 Sample Date: 02/27/2020 Matrix: GAS Collection Point: BDH Type: BDH Lab: ISOTECH| Sample Results for Sample # 616740 ISOTECH ID: 756427 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SOP | ARGON | 0.621 | MOL % | 0.005 | | | SOP | BRITISH THERMAL UNITS | 376 | BTU | | | | SOP | BUTANE | 0.276 | MOL % | 0.0001 | | | SOP | C6+ (hexanes +) | 0.009 | MOL % | 0.0001 | | | SOP | CARBON DIOXIDE | 0.056 | MOL % | 0.005 | | | SOP | CARBON MONOXIDE | ND | MOL % | 0.01 | ND | | SOP | DELTA 13C C1 | -50.94 | ‰ | | | | SOP | DELTA 13C C2 | -32.61 | ‰ | | | | SOP | DELTA 13C C3 | -29.52 | ‰ | | | | SOP | DELTA 13C iC4 | -31.62 | ‰ | | | | SOP | DELTA 13C nC4 | -28.36 | ‰ | | | | SOP | DELTA D C1 | -226.9 | ‰ | | | | SOP | ETHANE | 2.73 | MOL % | 0.0001 | | | SOP | ETHENE | 0.0001 | MOL % | 0.0001 | | | SOP | Helium | 0.0138 | MOL % | 0.005 | | | SOP | HYDROGEN | 0.99 | MOL % | 0.01 | | | SOP | HYDROGEN SULFIDE | ND | MOL % | 0 | ND | | SOP | ISOBUTANE | 0.193 | MOL % | 0.0001 | | | SOP | ISOPENTANE | 0.0413 | MOL % | 0.0001 | | | SOP | METHANE | 26.48 | MOL % | 0.0002 | | | SOP | NITROGEN (N2) | 53.3 | MOL % | 0.01 | | | SOP | OXYGEN (O2) | 13.78 | MOL % | 0.01 | | | SOP | PENTANE | 0.0283 | MOL % | 0.0001 | | | SOP | PROPANE | 1.48 | MOL % | 0.0001 | | | SOP | PROPENE | 0.0002 | MOL % | 0.0001 | | | SOP | SPECIFIC GRAVITY | 0.887 | RATIO_AIR | | |
Sample ID: 616738 Sample Date: 02/27/2020 Matrix: WATER Collection Point: BDH Type: BDH Lab: Accutest| Sample Results for Sample # 616738 Accutest ID: DA24499-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | E200.7 | BORON | 0.658 | mg/L | 0.05 | | | E200.7 | CALCIUM | ND | mg/L | 0.4 | U | | E200.7 | IRON | 0.484 | mg/L | 0.01 | | | E200.7 | MAGNESIUM | ND | mg/L | 0.2 | U | | E200.7 | MANGANESE | 0.0069 | mg/L | 0.005 | | | E200.7 | POTASSIUM | 66.3 | mg/L | 1 | | | E200.7 | SODIUM | 676 | mg/L | 0.4 | | | E200.7 | STRONTIUM | 0.0054 | mg/L | 0.005 | | | E200.8 | BARIUM | 0.0455 | mg/L | 0.004 | | | E200.8 | SELENIUM | 0.0018 | mg/L | 0.0012 | | | E300.0 | BROMIDE | 0.35 | mg/L | 0.25 | | | E300.0 | CHLORIDE | 166 | mg/L | 25 | | | E300.0 | FLUORIDE | 1.4 | mg/L | 0.5 | | | E300.0 | NITRATE | 0.8 | mg/L | 0.25 | | | E300.0 | Nitrite as NO2 | ND | mg/L | 0.02 | U | | E300.0 | SULFATE | 330 | mg/L | 25 | | | FIELD | pH, FIELD | 12.4 | SU | | | | FIELD | SPECIFIC CONDUCTIVITY, FIELD | 3290 | UMHOS/CM | 0.5 | | | FIELD | TEMPERATURE, FIELD | 10 | degrees C | | | | SM1030 | CATION - ANION BALANCE | 7.1 | % | | | | SM2320B | BICARBONATE ALKALINITY as CACO3 | ND | mg/L | 5 | U | | SM2320B | CARBONATE ALKALINITY AS CACO3 | 687 | mg/L | 5 | | | SM2320B | TOTAL ALKALINITY AS CACO3 | 762 | mg/L | 5 | | | SW8015 | TVPH - Gasoline Range Organics | 9.43 | mg/L | 1.3 | | | SW8260 | BENZENE | 16.4 | ug/L | 10 | | | SW8260 | ETHYLBENZENE | 32.9 | ug/L | 10 | | | SW8260 | M-+P-XYLENE | 170 | ug/L | 10 | | | SW8260 | o-XYLENE | 364 | ug/L | 10 | | | SW8260 | TOLUENE | 74.1 | ug/L | 10 | | | SW8260 | TOTAL XYLENES | 534 | ug/L | 10 | |
Sample ID: 616739 Sample Date: 02/27/2020 Matrix: WATER Collection Point: TB Type: TB Lab: Accutest| Sample Results for Sample # 616739 Accutest ID: DA24500-1 | | Method Code | Param Description | Result Value | Units | Detection Limit | Qualifier | | SW8015 | TVPH - Gasoline Range Organics | ND | mg/L | 0.05 | U | | SW8260 | BENZENE | ND | ug/L | 1 | U | | SW8260 | ETHYLBENZENE | ND | ug/L | 1 | U | | SW8260 | M-+P-XYLENE | ND | ug/L | 1 | U | | SW8260 | o-XYLENE | ND | ug/L | 1 | U | | SW8260 | TOLUENE | ND | ug/L | 1 | U | | SW8260 | TOTAL XYLENES | ND | ug/L | 1 | U |
|
|