Skip to Main Content

COGIS DB

Sample Site Search

COGIS - Environmental Sample Site Information

 
#289199 Information View DocsDoc View GISGIS
Sample Site ID289199
FacilityTypeOGProj Number
CountyWELD - 123LocationNWSE 36 3N67W
Elevation4817Lat/Long40.18011/-104.8366
DWR Receipt #WellDepth
 
Related Facility/Well
API Number: 05-123-24761Well Name:NISHIMOTO 24-36
Well Status:PAOperator Name:KERR MCGEE OIL & GAS ONSHORE LP
Location:NWSE  36 3N  67W

 
CECMC Water Quality Database Disclaimer
The analytical data And other information In this database are a compilation Of data collected by CECMC staff, Data submitted To CECMC from a variety Of third parties, And historical data. All analytical data collected by Or submitted To the CECMC Is Public information And CECMC posts the data To this database As a Public service. The data Is provided For informational purposes only. CECMC does Not conduct a detailed review Of quality control/quality assurance protocols, chain Of custody procedures, Or field Or laboratory methodologies On data received from third parties. The level Of review performed On historical data Is unknown. CECMC does Not regularly perform formal data validation For any Of the data posted To this database. The CECMC makes no warranties Or representations Of any kind, express Or implied, regarding the quality, accuracy, reliability, merchantability, Or fitness For a particular purpose Of the data provided herein.

Sample(s)
  

 Sample ID:   565748     Sample Date:  02/13/2018     Matrix:  GAS     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 565748    Dolan Integration Group ID: DIG-014109
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1149BTU/cuft
SOPBUTANE0.79MOL %0.005
SOPC6+ (hexanes +)0.2MOL %0.005
SOPCARBON DIOXIDENDMOL %0.005ND
SOPDELTA 13C C1-47.3per mil
SOPDELTA 13C C2-32.4per mil
SOPDELTA 13C C3-28.1per mil
SOPDELTA 13C iC4-31.1per mil
SOPDelta 13C iC5-28.5per mil
SOPDELTA 13C nC4-26.9per mil
SOPDelta 13C nC5-27.6per mil
SOPDELTA D C1-251per mil
SOPETHANE8.15MOL %0.005
SOPETHENENDMOL %0.005ND
SOPHelium0.02MOL %0.005
SOPHYDROGEN0.14MOL %0.005
SOPISOBUTANE0.3MOL %0.005
SOPISOPENTANE0.28MOL %0.005
SOPMETHANE86.39MOL %0.005
SOPNITROGEN (N2)0.82MOL %0.005
SOPOXYGEN + ARGON0.12MOL %0.005
SOPPENTANE0.26MOL %0.005
SOPPROPANE2.54MOL %0.005
SOPSPECIFIC GRAVITY0.653RATIO_AIR

 Sample ID:   565750     Sample Date:  02/13/2018     Matrix:  GAS     Collection Point:  PRDC     Type:  PRDG     Lab:  Dolan Integration Group

Sample Results for Sample # 565750    Dolan Integration Group ID: DIG-014108
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
SOPBRITISH THERMAL UNITS1246BTU/cuft
SOPBUTANE1.59MOL %0.005
SOPC6+ (hexanes +)0.01MOL %0.005
SOPCARBON DIOXIDE1.98MOL %0.005
SOPDELTA 13C C1-46.7per mil
SOPDELTA 13C C2-32per mil
SOPDELTA 13C C3-28.4per mil
SOPDELTA 13C CO24.3per mil
SOPDELTA 13C iC4-31.2per mil
SOPDelta 13C iC5-28.1per mil
SOPDELTA 13C nC4-27.5per mil
SOPDelta 13C nC5-27.6per mil
SOPDELTA D C1-251per mil
SOPETHANE14.32MOL %0.005
SOPETHENE0MOL %0.005
SOPHelium0.01MOL %0.005
SOPHYDROGEN0.04MOL %0.005
SOPISOBUTANE0.72MOL %0.005
SOPISOPENTANE0.21MOL %0.005
SOPMETHANE74.37MOL %0.005
SOPNITROGEN (N2)0.53MOL %0.005
SOPOXYGEN + ARGON0.11MOL %0.005
SOPPENTANE0.16MOL %0.005
SOPPROPANE5.96MOL %0.005
SOPSPECIFIC GRAVITY0.744RATIO_AIR

 Sample ID:   565752     Sample Date:  02/13/2018     Matrix:  LIQUID     Collection Point:  BDH     Type:  BDH     Lab:  Dolan Integration Group

Sample Results for Sample # 565752    Dolan Integration Group ID: 6126795471
Method CodeParam DescriptionResult ValueUnitsDetection LimitQualifier
G02G1,1,3-Trimethylcyclopentane1976ppm
G02G1,1-dimethylcyclopentane2313ppm
G02G1,2,3-trimethylcyclopentane1215ppm
G02G1,2,4-trimethylcyclopentane1586ppm
G02G2,2,3-trimethylbutane200ppm
G02G2,2-DIMETHYLBUTANE780ppm
G02G2,2-dimethylpentane1063ppm
G02G2,3-DIMETHYLBUTANE3159ppm
G02G2,3-dimethylpentane463ppm
G02G2,3-dimethylpentane2736ppm
G02G2,4-dimethylpentane2210ppm
G02G2-METHYLPENTANE19037ppm
G02G3-ethylpentane638ppm
G02G3-methylhexane10306ppm
G02G3-methylhexane10728ppm
G02G3-METHYLPENTANE11650ppm
G02GBENZENE4335ppm
G02GBUTANE10848ppm
G02Gcis-1,3-dimethylcyclopentane2955ppm
G02GCYCLOHEXANE15325ppm
G02GCYCLOPENTANE2546ppm
G02GDecane10726ppm
G02GETHYLBENZENE1606ppm
G02Gethylcyclopentane853ppm
G02GHEPTANES, MIXED ISOMERS25921ppm
G02GHEXANES34266ppm
G02Ghighly branched C25 isoprenoid222ppm
G02GISOBUTANE2435ppm
G02GISOPENTANE18649ppm
G02Gisoprenoid C102389ppm
G02Gisoprenoid C112388ppm
G02Gisoprenoid C132287ppm
G02Gisoprenoid C141765ppm
G02Gisoprenoid C152255ppm
G02Gisoprenoid C162973ppm
G02Gisoprenoid C182531ppm
G02Gisoprenoid C91999ppm
G02Gm-XYLENE10069ppm
G02GMETHYL CYCLOHEXANE27656ppm
G02GMETHYLCYCLOPENTANE14063ppm
G02Gn-C1110109ppm
G02Gn-C129040ppm
G02Gn-C138796ppm
G02Gn-C148250ppm
G02Gn-C157571ppm
G02Gn-C166393ppm
G02Gn-C175781ppm
G02Gn-C184882ppm
G02Gn-C194386ppm
G02Gn-C204134ppm
G02Gn-C213509ppm
G02Gn-C223205ppm
G02Gn-C232856ppm
G02Gn-C242535ppm
G02Gn-C252181ppm
G02Gn-C261947ppm
G02Gn-C271516ppm
G02Gn-C281283ppm
G02Gn-C291179ppm
G02Gn-C30951ppm
G02Gn-C31769ppm
G02Gn-c32590ppm
G02Gn-C33528ppm
G02Gn-C34455ppm
G02Gn-C35261ppm
G02Gn-C36161ppm
G02Gn-C37114ppm
G02Gn-C3869ppm
G02Gn-C3958ppm
G02Gn-C4053ppm
G02Gn-C418ppm
G02Gn-octane17728ppm
G02GNormal Alkane C912548ppm
G02Go-XYLENE4121ppm
G02Gp-XYLENE3462ppm
G02GPENTANE27888ppm
G02GPHENANTHRENE192ppm
G02Gphytane1710ppm
G02Gpristane2966ppm
G02GPropyl-benzene1163ppm
G02GTOLUENE14922ppm
G02Gtrans-1,2-dimethylcyclopentane4130ppm
G02Gtrans-1,3-dimethylcyclopentane2730ppm