WELL05-123-20181HSR STREAR
3-10A
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
1/21/2014
WATTENBERG
90750
WELD  123
NENW 10 2N67W 6
331114View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06 )
400526944
12/16/2013
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 2) If unable to pull casing, contact COGCC for plugging modifications. 3) Leave at least 100’ cement in the wellbore for each plug. 4) For 1250' plug: pump plug and displace, shut-in, WOC 4 hours and tag plug – must be 550’ or shallower. 5) Properly abandon flowlines as per Rule 1103.
 