Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08685NEWTON ASSOCIATED UNIT
D2X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
7/30/2025
RANGELY
72370
RIO BLANCO  103
NWNW 3 1N102W 6
315545View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (04)
403247357
12/13/2022
TA/Observation Well COAs 1)Complete MITs and regulatory requirements as required for Observation Wells 2)The Form 7 reporting must reflect the well status 3)A Form 5A is required to report all plugs currently downhole which isolate the perforated interval.
EngineerForm: (04)
403869927
07/30/2024
1) For applicable operations, submit a Form 5 within 30 days of the work with job related documents including a minimum of one of the following attachments: operations summary, cement job summary and/or wireline summary. Additionally, include CBL’s and any additional logs run.
OGLAForm: (04)
403869927
07/30/2024
Due to proximity to a wetland, surface water and expected shallow groundwater, operator will use secondary containment for all tanks and other liquid containers. Operator will implement stormwater BMPs and erosion control measures as needed to prevent sediment and stormwater runoff from entering the wetland and surface water. LAS review complete.
EngineerForm: (02)
403828720
12/10/2024
1) Submit Form 42 electronically to ECMC 2 business days prior to MIRU 2) If a sample has not been collected within the last twelve months collect bradenhead and production gas samples for laboratory analysis. Sampling will comply with Operator Guidance - Bradenhead Testing and Reporting Instructions, Appendix A: Liquid and Gas Sampling. Copies of all final laboratory analytical results will be provided to the ECMC within three months of collecting the samples. Sampling is required to be completed prior to the the submission of the Form 33 Subsequent. 3) If remedial cement is placed, it shall be verified with a CBL and Form 21 MIT
 
COGIS - Best Management Practice Results
No records to display.