Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-073-06404CRAIG
6-4
KTM OPERATING LLC
10722
TA
7/17/2023
BOLERO
7153
LINCOLN  073
SENW 4 14S55W 6
415505View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
AgencyForm: (02)
2105139
02/19/2010
1) Provide 24 hour notice of MIRU to Mike Leonard at 719-767-2805 or e-mail at mike.leonard@ state.co.us. 2) If production casing is set provide cement coverage to at least 200’ above Cherokee, and stage cement Cheyenne/Dakota interval (3750’-3200’ minimum). Run and submit CBL to verify all cemented intervals. 3) If well is a dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Arbuckle, 40 sks cement +/- 50’ above the Mississippian, 40 sks cement +/- 50’ above the Cherokee, 40 sks cement across any DST w/ show, 40 sks cement 100’ below Cheyenne (3750’ up), 40 sks cement 50’ above top of Dakota (3200’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of surface casing, cut 4 ft below GL, weld on plate, 5 sks cement each in rat hole and mouse hole.
EngineerForm: (04)
403467361
08/01/2023
1) Well last produced 07/2013, and has been designated as Inactive on 07/31/2013. Within 6 months of a Well becoming Inactive action must be taken. No later than 01/07/2024, this well was to: A. Be plugged and Abandoned, B. Return to production so that it is no longer an Inactive Well, C. Have an approved Form 5B, Inactive Well Notice, D. Be designated as Out of Service by submitting a Form 6A, Out of Service Designation.
 
COGIS - Best Management Practice Results
No records to display.