TypeSource DocumentConditions of Approval
AgencyForm: (02 )
1783957
7/24/2009
<style type="text/css"> p {margin:0px 0px 0px 2px;} ul {margin-top:2px;margin-bottom:2px;} ol {margin-top:2px;margin-bottom:2px;} H1 {font-family:Arial;font-size:28px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;} H2 {font-family:Arial;font-size:24px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;} H3 {font-family:Arial;font-size:18px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;} .Normal {font-family:Arial;font-size:14px;text-align:Left;vertical-align:Middle;color:#000000;} .TableDefault {border-collapse:collapse;border:1px solid #000000;} .TableDefault th {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;} .TableDefault td {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;} </style> <p><span class="Normal">1) Provide 24 hour notice of MIRU to Mike Leonard at 719-767-2805 or e-mail at mike.leonard@ state.co.us. </span><span class="Normal">2) If production casing is set provide cement coverage to at least 200’ above Lansing, and stage cement </span><span class="Normal">Cheyenne &amp; Dakota (4630’-4070’ minimum). Run CBL to verify primary and stage cement jobs. 3) If well is a </span><span class="Normal">dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Lansing, 40 sks cement above any </span><span class="Normal">DST zone, 40 sks cement 100’ below base of Cheyenne (4630’ up), 40 sks cement 50’ above top of Dakota </span><span class="Normal">(4070’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 10 sks cement in top of </span><span class="Normal">surface casing, cut 4 ft below GL, weld on plate, 5 sks cement in rat hole and mouse hole.</span></p>
AgencyForm: (02 )
1783957
7/29/2009
<style type="text/css"> p {margin:0px 0px 0px 2px;} ul {margin-top:2px;margin-bottom:2px;} ol {margin-top:2px;margin-bottom:2px;} H1 {font-family:Arial;font-size:28px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;} H2 {font-family:Arial;font-size:24px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;} H3 {font-family:Arial;font-size:18px;text-align:Left;vertical-align:Middle;color:#000000;font-weight:bold;} .Normal {font-family:Arial;font-size:14px;text-align:Left;vertical-align:Middle;color:#000000;} .TableDefault {border-collapse:collapse;border:1px solid #000000;} .TableDefault th {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;} .TableDefault td {padding:2px;vertical-align:top;text-align:left;border:1px solid #000000;} </style> <p><span class="Normal">SEE ATTACHED NOTICE CONCERNING OPERATING REQUIREMENTS FOR WILDLIFE PROTECTION</span></p>
EngineerForm: (02 )
1636653
6/15/2011
1) Provide 24 hour notice of MIRU to Craig Quint at 719-767-8939 or e-mail at craig.quint@state.co.us. 2) If production casing is set provide cement coverage to at least 200’ above the Marmaton, and across the Cheyenne/Dakota (4550’-4100’ minimum). Run and submit CBL to verify cemented intervals. 3) If well is a dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Marmaton, 40 sks cement across any DST w/ show, 40 sks cement 50’ below Cheyenne (4550’ up), 40 sks cement 50’ above top of Dakota (4100’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of surface casing, cut 4 ft below GL, weld on plate, 5 sks cement each in rat hole and mouse hole.
EnvironmentalForm: (04 )
400961244
12/31/2015
Operator will submit Form 27 remediation plan by February 29, 2016. No form 19 spill report will be required.
Reclamation SpecialistForm: (04 )
402250286
12/5/2019
Approval/Passing of the form 4 acknowledges that the Oil and Gas Conservation Commission has received the notice. A field inspection will be conducted at a future date to evaluate compliance with reclamation standards.
Reclamation SpecialistForm: (04 )
402822662
12/20/2021
COGCC will not require further action at this time. If any future disturbances (i.e., subsequent operations) affect interim reclamation vegetation, Operator shall reclaim all disturbances as early as practicable to meet Rule 1003 standards. Should future conditions at the site indicate poor growth that is not reflective of reference areas, then further investigation and reclamation activities may be required.
 
COGIS - Best Management Practice Results