Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-36823Breakneck Properties
21-6
CRESTONE PEAK RESOURCES OPERATING LLC
10633
SI
1/1/2023
WATTENBERG
90750
WELD  123
NWNE 6 3N68W 6
431859View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
PermitForm: (02)
400367210
01/18/2013
Operator must meet water well testing requirements per Rule 318A.
EngineerForm: (02)
400367210
01/28/2013
1) Note surface casing setting depth change from 400’ to 840’. Increase cement coverage accordingly. 2) Submit Form 42 electronically to COGCC 48 hours prior to MIRU. 3) Comply with Rule 317.i and provide cement coverage from TD to a minimum of 200' above Niobrara. Verify coverage with cement bond log. 4) Run and submit Directional Survey from TD to base of surface casing. The operator shall comply with Rule 321, and it shall be the operator’s responsibility to ensure that the wellbore complies with setback requirements in commission orders or rules prior to producing the well.
 
COGIS - Best Management Practice Results
No records to display.