WELL05-123-07939ANDERSON FAMILY TRUST C
1
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
6/29/2016
WATTENBERG
90750
WELD  123
SWNE 34 3N68W 6
336097View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (06 )
400897704
12/14/2015
Note changes to plugging procedure: 1) Provide 48 hour notice of plugging MIRU via electronic Form 42. 2) For 780’ plug: pump plug and displace. If surface casing plug is not circulated to surface then tag plug – must be 108’ or shallower and provide 10 sx plug at the surface. Leave at least 100’ of cement in the casing for each plug. 3) Properly abandon flowlines as per Rule 1103. File electronic Form 42 once abandonment complete.
 