Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-073-06460Napali
4
WIEPKING-FULLERTON ENERGY LLC
96340
PR
7/1/2020
GREAT PLAINS
32756
LINCOLN  073
NESW 17 10S55W 6
425332View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02 )
400193338
8/17/2011
1) Provide 24 hour notice of MIRU to Craig Quint at 719-767-8939 or e-mail at craig.quint@state.co.us. 2) If production casing is set provide cement coverage to at least 200’ above the Marmaton, and stage cement Cheyenne/Dakota (4500’-3950’ minimum). Run and submit CBL to verify cemented intervals. 3) If well is a dry hole set plugs at the following depths: 40 sks cement +/- 50’ above the Marmaton, 40 sks cement across any DST w/ show, 40 sks cement 50’ below Cheyenne (4500’ up), 40 sks cement 50’ above top of Dakota (3950’ up), 50 sks cement from 50’ below surface casing shoe up into surface casing, 15 sks cement in top of surface casing, cut 4 ft below GL, weld on plate, 5 sks cement each in rat hole and mouse hole.
PermitForm: (04 )
400534313
1/6/2014
A new form 2 needed since permit expired and the Torch is a new formation objective.
PermitForm: (02 )
400534697
2/4/2014
Operator shall comply with Buffer Zone Move-In, Rig-Up Notice Policy dated 12-16-2013.
PermitForm: (02 )
400534697
2/4/2014
Open hole resistivity and gamma logs shall be run to describe the stratigraphy of the entire well bore and to adequately verify the setting depth of surface casing and aquifer coverage. On a multi-well pad, these open hole logs are only required on one of the first wells drilled on the pad and the Drilling Completion Report - Form 5 for every well on the pad shall identify which well was logged.
EnvironmentalForm: (04 )
400961329
12/31/2015
Operator will submit Form 27 remediation plan by February 29, 2016. No form 19 spill report will be required.
Reclamation SpecialistForm: (04 )
401294500
5/31/2017
Approval/passing of the form 4 acknowledges that the Oil and Gas Conservation Commission has received the Notice. It is not an acknowledgement that inspection has been passed. A field inspection will be conducted to evaluate compliance with COGCC standards.
Reclamation SpecialistForm: (04 )
402822671
12/20/2021
COGCC will not require further action at this time. If any future disturbances (i.e., subsequent operations) affect interim reclamation vegetation, Operator shall reclaim all disturbances as early as practicable to meet Rule 1003 standards. Should future conditions at the site indicate poor growth that is not reflective of reference areas, then further investigation and reclamation activities may be required.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Storm Water/Erosion ControlForm: (02 )
400193338
9/12/2011
BMP Plan Wiepking-Fullerton Energy, L.L.C. 4600 S. Downing St. Englewood, CO 80113 303-789-1798 303-761-9067 (fax) Certification to Discharge Under CDPS General Permit COR-03000 Stormwater Discharges Associated with Construction Certification Number COR 39788 Napali # 4 well T10S, R55W Sec. 17: NE1/4SW1/4 Lincoln County, Colorado Description of Well Site and Construction Area 1-3 acre site with access road for drilling of oil and gas well. Terrain is flat with native grass and sagebrush. No receiving waters will be affected by well pad. Silt fences will be installed on low side site of drill site. Drilling pits closed and reclaimed with the drillsite. Topsoil will be separated and spread on drill site as final operation before reseeding operations which will be completed within 6 months weather permitting. To prevent soil erosion site will be disked and straw crimped in or manure spread. Stormwater Management Plan (SWMP) is on file in Wiepking-Fullerton Energy, L.L.C. office. Spill Prevention, Control and Countermeasure Plan is on file in Wiepking-Fullerton Energy, L.L.C. office.
ConstructionForm: (04 )
400534313
1/13/2014
No additional surface disturbance required for Napali #4 recompletion operation