Skip to Main Content

COGIS DB

 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-039-06682Vermillion
1
KTM OPERATING LLC
10722
PR
12/1/2025
WILDCAT
99999
ELBERT  039
SWNE 2 13S58W 6
449576View Related
 
COGIS - Conditions of Approval Results
TypeSource DocumentConditions of Approval
EngineerForm: (02)
401209239
03/08/2017
Cement Bond Log will be run on both the 7" casing and the 4-1/2" casing if set.
EngineerForm: (02)
401209239
03/08/2017
Bradenhead tests shall be performed and reported according to the following schedule and Form 17 submitted within 10 days of each test.: 1) Within 60 days of rig release, prior to stimulation. 2) 6 months after rig release, prior to stimulation. 3) Within 30 days of first production, as reported on Form 5A.
EngineerForm: (02)
401209239
03/08/2017
1) Submit Form 42 electronically to COGCC 48 hours prior to MIRU for the first well activity with a rig on the pad. 2) Comply with Rule 317.i. and provide cement coverage from end of 7" casing to a minimum of 200' above Niobrara and from TD of 4-1/2" casing to 100' into the 7" casing shoe. Verify coverage with cement bond log.
 
COGIS - Best Management Practice Results
BMP TypeSource DocumentBest Management Practices
Drilling/Completion OperationsForm: (02 )
401209239
3/9/2017
Open-hole Resistivity Log with Gamma Ray Log will be run from TD into the surface casing. A Cement Bond Log with Gamma-Ray will be run on production casing, or on intermediate casing if a production liner is run. The Form 5, Completion Report, will list all logs run and have those logs attached.