| Planning | Form: (02 ) 400525148 2/8/2014 | Guy Line Anchors: Per the SUA, Ward will remove all guy line anchors for drilling and completions within 30 days upon termination of oil and gas operations by Ward. |
| Planning | Form: (02 ) 400525148 2/8/2014 | Development from existing well pads: Development from existing well pads was not an option for this well. However, this well pad will be considered for future well locations. |
| Planning | Form: (02 ) 400525148 2/8/2014 | Site Specific Measures: Ward will maintain a Stormwater Management Plan with site specific measurements to assess erosion control. |
| Planning | Form: (02 ) 400525148 2/8/2014 | Multiwell Pads: In order to reduce surface disturbance, Ward is permitting this 2A for five (5) wells. |
| Traffic control | Form: (02 ) 400525148 2/8/2014 | Traffic Plan: A traffic plan will be done if required by Adams County. |
| Traffic control | Form: (02 ) 400525148 2/8/2014 | Access Roads: Ward will utilize Highway and County roads as well as the agreed upon access road to the surface location per the SUA. Any required county permits will be obtains prior to use. |
| General Housekeeping | Form: (02 ) 400525148 2/8/2014 | Loadlines: All loadlines shall be bullplugged or capped. |
| General Housekeeping | Form: (02 ) 400525148 2/8/2014 | Removal of Surface Trash: Per the SUA, Ward agrees that all trash, refuse pipe, equipment, liquids, chemicals of other materials that are not necessary for the continued operations of the wells will be removed and disposed of no later than 30 days after completion. No such items will be burned or buried on location. |
| General Housekeeping | Form: (02 ) 400525148 2/8/2014 | Well Site Cleared: Per the SUA, Ward agrees that all trash, refuse pipe, equipment, liquids, chemicals of other materials that are not necessary for the continued operations of the wells will be removed and disposed of no later than 30 days after completion. No such items will be burned or buried on location. |
| Material Handling and Spill Prevention | Form: (02 ) 400525148 2/8/2014 | Leak Detection Plan: To ensure protection for the surface during fracturing treatment, the location will be specifically constructed to contain any releases or spills. Secondary containment from any chemical spills or leaks will surround any trucks that carry, mix, or add chemicals to the flow stream as well as connections that could possibly leak fluid. Should any spill or release occur, every reasonable step will be taken to quickly remediate the area disturbed. |
| Material Handling and Spill Prevention | Form: (02 ) 400525148 2/8/2014 | Control of Fire Hazards: Ward and its contractor’s employ best management practices during the drilling and production of its wells and facilities. They will comply with appropriate COGCC and any county rules concerning fire and safety. Ward will ensure that any flammable material will remain no less than 25 feet from the wellhead(s), tanks and separator(s). |
| Construction | Form: (02 ) 400525148 2/8/2014 | Berm Construction: A containment berm will be constructed around the oil and water storage tanks. The berm will be inspected regularly and maintained in good condition. |
| Construction | Form: (02 ) 400525148 2/8/2014 | Fencing: Per the SUA, during drilling operations the well sites and any pits shall be fenced of required by the Owner. |
| Noise mitigation | Form: (02 ) 400525148 2/8/2014 | Noise: No noise mitigation will required for this location. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | Closed Loop System: Closed Loop System will be used for drilling and fluid management. No reserve pit will be used. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | Green Completions: Ward will comply with COGCC Rule 805b.(3)A and utilize Green Completion Methods. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | BOPE Testing: Upon initial rig-up and once every 30 days during drilling operations, pressure testing of the casing string and each component of the BOPE will be performed to 70% of working pressure or 70% of the internal yield of the casing, whichever is less. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | BOPE for well servicing operations: Adequate blowout prevention equipment will be used on any servicing operations associated with this well. Backup staving valves shall be required on well servicing operations during reverse circulation. Valves will be pressure tested before each well servicing operation using both low-pressure and high-pressure fluid. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | BOPE: Ward will utilize drilling rigs with a minumum of a double ram and annular preventer. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | Drill Stem Tests: Drill Stem Tests are not anticipated for this location. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | Tank specifications: Tanks shall be constructed and maintained in accordance with the National Fire Protection Association Code 30 (2008 version). All tanks will be visually inspected once a day for issues. Recorded inspections will be conducted once a month pursuant to 40 CFR §112. |
| Drilling/Completion Operations | Form: (02 ) 400525148 2/8/2014 | Pit Level Indicators: Pit Level Indicators will not be needed as no pits will be used on location. |
| Final Reclamation | Form: (02 ) 400525148 2/8/2014 | Identification of Plugged and Abandoned Wells: Pursuant to Rule 319.a.(5)., once the well has been plugged and abandoned, Ward will identify the location of the wellbore with a permanent monument that will detail the well name and date of plugging. |
| Planning | Form: (02 ) 400635520 6/30/2014 | Guy Line Anchors: Per the SUA, Ward will remove all guy line anchors for drilling and completions within 30 days upon termination of oil and gas operations by Ward. |
| Planning | Form: (02 ) 400635520 6/30/2014 | Developement from existing well pads: Developement from existing well pads was not an option for this well. However, this well pad will be considered for future well locations. |