Skip to Main Content

Incident Search

COGIS - Remediation Reports
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-123-30571ADAM FARM
2-4
KERR MCGEE OIL & GAS ONSHORE LP
47120
PA
8/4/2017
WATTENBERG
90750
FIRESTONE/WELD  123
SWNE 4 2N68W 6
318150View Related Related
 
Form 27/27AView Related Related View DocsDoc
Date Submitted:7/16/2024
Date Recv'd:7/16/2024Assigned by:Kari Brown
DocNum:403849289API number:05-123-30571
Document Type:FORM 27 Project Number:36238
Operator Information:
Operator:KERR MCGEE OIL & GAS ONSHORE LP
Oper. No.47120
Address:P O BOX 173779  DENVER  CO 80217-3779
Type Of Facility:SPILL OR RELEASE
Fac. NameAdam Farm 27-4 Wellhead
County Name:WELD
Operator contact:Erik Mickelson
qtrqtr: SWNEsection: 4township: 2Nrange: 68Wmeridian: 6
Remediation Details:
Impacted Media
MediaImpactedExtentHow Determined?
GROUNDWATER UTBD Groundwater Samples/Laboratory Analytical Results
SOILS UTBD Soil Samples/Laboratory Analytical Results
Reason for Report: OTHER
Cause of Condition: OTHER
Potential Receptors: St. Vrain Creek 670 feet (ft) southeast. Ponds 250 ft south and 1,160 ft southeast. Water well 410 f
 
HOW REMEDIATE:  Potential impacts that meet the criteria in Rule 912.b. will be reported to the Director in accordance with that Rule and a site-specific soil and/or groundwater remediation plan will be developed and submitted to the ECMC via a supplemental Form 27 in accordance with Rule 913. If reportable impacts are not encountered, a supplemental Form 27 requesting closure will be submitted within 90 days following completion of sampling activities. Field screening and applicable laboratory analytical results will be reported in all submittals. E&P waste records of material transported off-site are kept on file and available upon request.
 
INITIAL ACTION:  This form has been prepared to provide prior notice of the plugging and abandonment the Adam Farm 1, 21, 27, 28-4 wellheads and the removal of the associated flowlines, and the flowlines associated with the previously plugged and abandoned Adams George GU 1 and Adam Farm 2, 7, 8-4 wellheads. The wellheads were previously plugged and abandoned between 2017 and 2021. The flowlines will be permanently removed. The off-location flowline system pre-removal notice was submitted under Form 44 Document #s 403841834, 403841941, & 403841945. In accordance with ECMC Rule 911.a., soil and groundwater (if present) samples will be collected and submitted for laboratory analysis to determine if concentrations and values are in compliance with ECMC Table 915-1. Visual inspection and field screening of soils around the Adam Farm 1, 21, 27, 28-4 wellheads and all flowlines will be conducted during sampling activities. Soil vapor screening will also be performed around the Adam Farm 1, 21, 27, 28-4 wellheads. The topographic Site Location Map showing the geographic setting of the site is provided as Figure 1. The Form 44s are attached.
 
RECLAMATION PLAN:  The site will be reclaimed in accordance with ECMC 1000 Series Reclamation Rules.
 
SOURCE REMOVED:  If a suspected release is identified and confirmed through soil screening and/or laboratory analysis, soils will be removed and transported to a licensed disposal facility. Disposal records will be kept on file and available upon request.
 
Correspondence Log:
Final Resolution
DateCase Closed?Letter Sent?CECMC Person
N/ANKari Brown
N/ANKari Brown
 
Coordinates:
TypeFacility IDFacility Name/NumLat/Long
Remediation240715ADAM, GEORGE GU
1
40.171317/-105.004270

Remediation412871ADAM FARM
27-4
40.171341/-105.004102

Remediation412872ADAM FARM
28-4
40.171391/-105.004133

Remediation412873ADAM FARM
21-4
40.171314/-105.004088

Remediation412874ADAM FARM
8-4
40.171241/-105.004041

Remediation412875ADAM FARM
1-4
40.171292/-105.004076

Remediation412876ADAM FARM
7-4
40.171265/-105.004057

Facility412877ADAM FARM
2-4
40.171370/-105.004116

Remediation488188Adam Farm 27-4 Wellhead
40.171341/-105.004102