Form 21 | Related Doc |
Date Submitted: | 1/17/2024 | MIT Assigned By: | |
Date Recv'd: | 1/17/2024 | Facility ID: | |
DocNum: | 403657533 | Facility Status: | |
Operator Information: |
Oper. No. | 10779 |
Operator: | SCOUT ENERGY MANAGEMENT LLC |
Address: | 13800 MONTFORT DRIVE SUITE 100 DALLAS TX 75240 |
Type Of Facility: | | Well Status: |
Facility Name | EMERALD |
Operator contact: | Anita Sanford |
Location: | | qtrqtr: | section: | township: | range: | meridian: |
|
MIT Details: |
Test Type: | VERIFICATION OF REPAIRS |
Repair Type: | |
Repair Desc: | WELL WAS SHUT IN 06/20/2023 FOR SUSPECTED TUBING FAILURE. Well work completed as follows. An attempt was made to fish out the SIE but fishing ops were called after only getting the top two packers. A casing leak was found from 4429-4461 and 3 cmt squeeze's were pumped to finally seal it off. Acid was used to breakdown the leak after the 2nd sqz didn't work. (1st sqz - 50 sxs 15.8# & 80 sks 13.4#, 2nd sqz - 20 sks 13.4#, 3rd sqz - 60 sks 15.8# & 20 sks 13.4#) |
Test Date: | 1/15/2024 |
Field Rep: | Browning, Chuck |
Approved Date: | 1/17/2024 |
Approved by: | |
Last Approved MIT: | 9/6/2018 |
Injection/Producing Formation Zones: | WEBR |
Perforation Interval: | 5742-6450 |
Open Hole Interval: | |
Bridge/Cement Plug Depth: | |
Tubing Size: | 2.875 |
Tubing Depth: | 6430 |
Top Packer Depth: | 5585 |
Multiple Packers: | |
|
Condition of approval: |
|
Test Data: | Wellbore Channel Test: | Reading Type | Pressure | 10 MIN CASE | 1275 | 5 MIN CASE | 1275 | FINAL CASE | 1275 | LOSS OR GAIN | -25 | START CASE | 1300 |
| No channel test. |
|
|
|
|