Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07546FEE
87X
SCOUT ENERGY MANAGEMENT LLC
10779
AC
6/1/2023
RANGELY
72370
RIO BLANCO  103
NWNE 28 2N102W 6
314915View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:2/4/2020MIT Assigned By:
Date Recv'd:2/4/2020Facility ID: 
DocNum:402302393Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameFEE
Operator contact:ANITA  SANFORD
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:1/31/2020
Field Rep:Browning, Chuck
Approved Date:2/4/2020
Approved by:
Last Approved MIT:4/13/2016
Injection/Producing Formation Zones:WEBR
Perforation Interval:5917-6450
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5317.3
Top Packer Depth:5332
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE350
5 MIN CASE350
FINAL CASE350
START CASE350
No channel test.