Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-10576MCLAUGHLIN UNIT B
2X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/15/2005
RANGELY
72370
RIO BLANCO  103
SWSE 12 2N103W 6
316464View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/19/2005MIT Assigned By:KOEHLER, BOB
Date Recv'd:2/22/2008API number: 05-103-10576
DocNum:1979889Facility Status:IJ
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:WELLWell Status: IJ
Well Name/No.MCLAUGHLIN UNIT B
Operator contact:DIANE L.  PETERSON
Location:  qtrqtr: SWSE section: 12 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:CONVERT TO INJECTION WELL. CLEAN OUT TO PBTD, RIH WITH 202 JOINTS FIBERLINED TUBING AND 7" ISOLATION PACKER.
Test Date:2/14/2008
Field Rep:
Approved Date:7/16/2008
Approved by:KOEHLER, BOB
Last Approved MIT:N/A
Injection/Producing Formation Zones:WEBR
Perforation Interval:6492-6650
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6452.4
Top Packer Depth:6365.5
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
No test data.
No channel test.