Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05636EMERALD
13
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/1/2023
RANGELY
72370
RIO BLANCO  103
SENE 26 2N103W 6
314406View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/9/2014MIT Assigned By:BROWNING, CHUCK
Date Recv'd:4/11/2014Facility ID: 150200
DocNum:1171617Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameEMERALD
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:INCREASE MAXIMUM INJECTION PRESSURE
Test Date:4/9/2014
Field Rep:BROWNING, CHUCK
Approved Date:4/9/2014
Approved by:BROWNING, CHUCK
Last Approved MIT:6/13/2013
Injection/Producing Formation Zones:WEBR
Perforation Interval:6128-6516
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6137.2
Top Packer Depth:6052.2
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE2218
5 MIN CASE2220
CASE BEFORE0
FINAL CASE2213
FINAL TUBE1262
INITIAL TUBE1262
LOSS OR GAIN-16
START CASE2229
No channel test.