Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08612FEE
53AX
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
2/1/2020
RANGELY
72370
RIO BLANCO  103
NWSW 22 2N102W 6
315502View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/29/2007MIT Assigned By:KRABACHER, JAY
Date Recv'd:7/30/2007Facility ID: 150200
DocNum:1170991Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:clean to 6335. replace 184 jts tubing. new packer
Test Date:6/27/2007
Field Rep:
Approved Date:7/30/2007
Approved by:KRABACHER, JAY
Last Approved MIT:5/9/2006
Injection/Producing Formation Zones:WEBR
Perforation Interval:6240 - 6574
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6016
Top Packer Depth:5930
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE825
5 MIN CASE825
CASE BEFORE0
FINAL CASE825
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE825
No channel test.