Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08299FEE
116X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/9/2022
RANGELY
72370
RIO BLANCO  103
NENW 19 2N102W 6
315323View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:7/13/2004MIT Assigned By:KRABACHER, JAY
Date Recv'd:9/29/2004Facility ID: 150200
DocNum:1170640Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:repl 191 j tubing and packer
Test Date:7/12/2004
Field Rep:
Approved Date:9/29/2004
Approved by:KRABACHER, JAY
Last Approved MIT:5/9/2002
Injection/Producing Formation Zones:WEBR
Perforation Interval:6029 - 6520
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5960
Top Packer Depth:5913
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE810
5 MIN CASE810
CASE BEFORE0
FINAL CASE810
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE810
No channel test.