Skip to Main Content

Incident Search

COGIS - Field Inspection Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-08299FEE
116X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/9/2022
RANGELY
72370
RIO BLANCO  103
NENW 19 2N102W 6
315323View Related Related
 
View Related RelatedView GISGISView Docs Doc
API Number: 05-103-08299Name: FEE #116X
Location: NENW 19 2N102WLat: 40.132370   Long: -108.890625
Operator #: 16700Operator Name: CHEVRON USA INC
Inspection Date: 1/12/1993Inspector: Historical Migration
Inspection was: No Satisfactory/Unsatisfactory Indicator
Insp. Type: Insp. Stat: Reclamation (Pass, Interim Or Fail): P&A (Pass/Fail): 
Brhd. Pressure: Inj. Pressure: T-C Ann. Pressure: UIC Violation Type: 
Violation: NOAV Sent: Date Corrective Action Due: N/ADate Remedied: 1/12/1993
 
Field Inspection Comments And Observations
Insp. CommentInspection/Violation Comments
HISTORICAL GROSS 1850 BW, NET 0 BW. SPLIT IN WELD OF LINE DUE TO CORROSION.TOOK 7 HOURS TO CONTROL LEAK. WATER RECOVERED BY VAC TRUCK AND TAKEN TO MAIN WATER PLANT DISPOSAL PIT. 8 FT SECTION OF LINE REPLACED, WILL EVALUATE CATHODIC PROTECTION.



 


Tuesday, March 4, 2025