Skip to Main Content

Incident Search

COGIS - Field Inspection Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-05770UNION PACIFIC
27-20
SCOUT ENERGY MANAGEMENT LLC
10779
AC
3/1/2023
RANGELY
72370
RIO BLANCO  103
NENE 20 2N102W 6
314470View Related Related
 
View Related RelatedView GISGISView Docs Doc
API Number: 05-103-05770Name: UNION PACIFIC #27-20
Location: NENE 20 2N102WLat: 40.133910   Long: -108.860110
Operator #: 16700Operator Name: CHEVRON USA INC
Inspection Date: 3/22/1997Inspector: Historical Migration
Inspection was: No Satisfactory/Unsatisfactory Indicator
Insp. Type: Insp. Stat: Reclamation (Pass, Interim Or Fail): P&A (Pass/Fail): 
Brhd. Pressure: Inj. Pressure: T-C Ann. Pressure: UIC Violation Type: 
Violation: NOAV Sent: Date Corrective Action Due: N/ADate Remedied: 3/22/1997
 
Field Inspection Comments And Observations
Insp. CommentInspection/Violation Comments
HISTORICAL GROSS 5 BO/10 BW, NET NOT SPECIFIED. RUPTURE IN DISK DUE TO UP SET FAILURE (NOT A PIPELINE). LOW PRESSURE GAS GATHERING LINE DRIP TRAP. NON DOT REGULATED. SHUT DOWN SYSTEM AND REPLACED DISK. SPILL WAS CONSTRAINED BY A DAM IN WASH. RELEASED PRODUCT WAS CLEANED UP BY CONTRACTOR.



 


Wednesday, November 13, 2024