Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09177UNION PACIFIC
37AX-29
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/1/2023
RANGELY
72370
RIO BLANCO  103
NWSE 29 2N102W 6
315755View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:12/21/2023MIT Assigned By:
Date Recv'd:12/21/2023Facility ID: 
DocNum:403633019Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameUNION PACIFIC
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:Fish out packer and attempt to fish/mill up joints left in hole. Cleaned out to 5881 feet. Return to injection pending approved Form 21.
Test Date:12/20/2023
Field Rep:Browning, Chuck
Approved Date:1/5/2024
Approved by:
Last Approved MIT:9/24/2020
Injection/Producing Formation Zones:WEBR
Perforation Interval:5656-6088
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5545
Top Packer Depth:5419
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1340
5 MIN CASE1340
FINAL CASE1340
LOSS OR GAIN-10
START CASE1350
No channel test.