WELL05-103-06141FEE
43
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
9/1/2023
RANGELY
72370
RIO BLANCO  103
SENW 19 2N102W 6
314569View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/22/2023MIT Assigned By:
Date Recv'd:9/22/2023Facility ID: 
DocNum:403538608Facility Status:
Operator Information:
Oper. No.10779
Operator:SCOUT ENERGY MANAGEMENT LLC
Address:13800 MONTFORT DRIVE SUITE 100  DALLAS  TX 75240
Type Of Facility:Well Status: 
Facility NameFEE
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:9/23 UIC Failure-ran 5 1/2" liner from 5801 ft to surface and cmt'd with 283 sks of 13.5# class G cmt.
Test Date:9/20/2023
Field Rep:Browning, Chuck
Approved Date:9/27/2023
Approved by:
Last Approved MIT:5/4/2018
Injection/Producing Formation Zones:WEBR
Perforation Interval:6003-6465
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5984
Top Packer Depth:5766
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1325
5 MIN CASE1330
FINAL CASE1320
LOSS OR GAIN-20
START CASE1340
No channel test.