Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06420MCLAUGHLIN, A C
56X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
2/2/2023
RANGELY
72370
RIO BLANCO  103
SESW 14 2N103W 6
314697View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:4/17/2023MIT Assigned By:
Date Recv'd:4/17/2023Facility ID: 
DocNum:403374828Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:760 HORIZON DRIVE STE 401  GRAND JUNCTION  CO 81506
Type Of Facility:Well Status: 
Facility NameMCLAUGHLIN, A C
Operator contact:Anita  Sanford
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:REMOVE INJECTION STRING AND PACKER, CLEAN OUT OPEN HOLE DOWN TO PBTD OF 6588.
Test Date:4/13/2023
Field Rep:Browning, Chuck
Approved Date:4/17/2023
Approved by:
Last Approved MIT:10/20/2022
Injection/Producing Formation Zones:WEBR
Perforation Interval:
Open Hole Interval:6260-6578
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6116
Top Packer Depth:6028
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1245
5 MIN CASE1250
FINAL CASE1245
LOSS OR GAIN-15
START CASE1260
No channel test.