Form 21 | Related Doc |
Date Submitted: | 2/23/2021 | MIT Assigned By: | |
Date Recv'd: | 2/23/2021 | Facility ID: | |
DocNum: | 402606430 | Facility Status: | |
Operator Information: |
Oper. No. | 16700 |
Operator: | CHEVRON USA INC |
Address: | 100 CHEVRON ROAD RANGELY CO 81648 |
Type Of Facility: | | Well Status: |
Facility Name | GRAY |
Operator contact: | ANITA SANFORD |
Location: | | qtrqtr: | section: | township: | range: | meridian: |
|
MIT Details: |
Test Type: | VERIFICATION OF REPAIRS |
Repair Type: | |
Repair Desc: | Well work to perforate 7" casing @ 808' squeezed with 95 sxs class G cement and Installed 5 1/2 " liner 0-5847' with 288 sks cement. |
Test Date: | 2/18/2021 |
Field Rep: | Browning, Chuck |
Approved Date: | 2/23/2021 |
Approved by: | |
Last Approved MIT: | 4/6/2018 |
Injection/Producing Formation Zones: | WEBR |
Perforation Interval: | 5907-6510 |
Open Hole Interval: | |
Bridge/Cement Plug Depth: | |
Tubing Size: | 2.875 |
Tubing Depth: | 6529.8 |
Top Packer Depth: | 5777 |
Multiple Packers: | |
|
Condition of approval: |
|
Test Data: | Wellbore Channel Test: | Reading Type | Pressure | 10 MIN CASE | 1265 | 5 MIN CASE | 1270 | FINAL CASE | 1260 | LOSS OR GAIN | -15 | START CASE | 1275 |
| No channel test. |
|
|
|
|