Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09285EMERALD
7A
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
7/1/2015
RANGELY
72370
RIO BLANCO  103
SENW 30 2N102W 6
315808View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/12/2020MIT Assigned By:
Date Recv'd:10/12/2020Facility ID: 
DocNum:402508695Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON ROAD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameEMERALD
Operator contact:ANITA  SANFORD
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:10/8/2020
Field Rep:Browning, Chuck
Approved Date:10/19/2020
Approved by:
Last Approved MIT:5/25/2016
Injection/Producing Formation Zones:WEBR
Perforation Interval:5636-6467
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6492
Top Packer Depth:5472.3
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1250
5 MIN CASE1250
FINAL CASE1250
FINAL TUBE2039
INITIAL TUBE2039
START CASE1250
No channel test.