Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-01052MCLAUGHLIN, A C
31
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/1/2023
RANGELY
72370
RIO BLANCO  103
SENE 15 2N103W 6
314258View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:12/6/2019MIT Assigned By:
Date Recv'd:12/6/2019Facility ID: 
DocNum:402256315Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON USA INC  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameMCLAUGHLIN, A C
Operator contact:ANITA  SANFORD
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:WELL BUILT CASING PRESSURE 11/23/2019 INSTALLED 5 1/2" LINER FROM SURFACT TO 6295.
Test Date:12/4/2019
Field Rep:Browning, Chuck
Approved Date:12/9/2019
Approved by:
Last Approved MIT:9/30/2015
Injection/Producing Formation Zones:WEBR
Perforation Interval:
Open Hole Interval:6401-6705
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6360.9
Top Packer Depth:6221.9
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1260
5 MIN CASE1260
FINAL CASE1260
LOSS OR GAIN-10
START CASE1270
No channel test.