Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07716MCLAUGHLIN, A C
63X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
2/15/2021
RANGELY
72370
RIO BLANCO  103
SESW 13 2N103W 6
314994View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:3/7/2019MIT Assigned By:
Date Recv'd:3/7/2019Facility ID: 
DocNum:401963909Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE  PETERSON
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:WELLWORK TO REPAIR CASING. RAN 5 1/2" CASING FROM SURFACE TO 6181'. TWO SQUEEZES TO REPAIR LEAKS BETWEEN 3648 AND 4310 FT. TOTAL 225 SACKS G-CEMENT
Test Date:3/6/2019
Field Rep:Browning, Chuck
Approved Date:3/7/2019
Approved by:
Last Approved MIT:8/18/2014
Injection/Producing Formation Zones:WEBR
Perforation Interval:6244-6576
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6188.6
Top Packer Depth:6001.9
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1290
5 MIN CASE1290
FINAL CASE1290
START CASE1290
No channel test.