Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-07526CARNEY C T
30 X 34
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
12/1/2019
RANGELY
72370
RIO BLANCO  103
SENE 34 2N102W 6
314906View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:7/28/2015MIT Assigned By:
Date Recv'd:7/28/2015Facility ID: 
DocNum:400875560Facility Status:
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:Well Status: 
Facility NameCARNEY C T
Operator contact:DIANE  PETERSON
Location:  qtrqtr:  section:  township:  range:  meridian: 
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:
Repair Desc:well would not blow down druing routine field inspection - test to verify integrity. Tubing and packers ran on 11/7/2000, correction to previously submitted packer depth.
Test Date:7/24/2015
Field Rep:Browning, Chuck
Approved Date:10/6/2015
Approved by:
Last Approved MIT:9/12/2014
Injection/Producing Formation Zones:WEBR
Perforation Interval:5726-6413
Open Hole Interval:
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6178
Top Packer Depth:5572
Multiple Packers:
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1250
5 MIN CASE1250
FINAL CASE1250
START CASE1250
No channel test.