WELL05-103-09196UNION PACIFIC
62AX-32
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
8/12/2022
RANGELY
72370
RIO BLANCO  103
NWNW 32 2N102W 6
336551View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:7/22/2011MIT Assigned By:KOEHLER, BOB
Date Recv'd:7/28/2011Facility ID: 150200
DocNum:1771453Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameUNION PACIFIC
Operator contact: 
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER AND CASING LEAK
Repair Desc:WELLWORK-FISH PACKERS, CLEAN OUT, RUN LINER AND RE-PERF, SQZ LINER TOP
Test Date:7/19/2011
Field Rep:
Approved Date:7/28/2011
Approved by:KOEHLER, BOB
Last Approved MIT:6/16/2009
Injection/Producing Formation Zones:WEBR
Perforation Interval:5662-6108
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:5645
Top Packer Depth:5116
Multiple Packers:Y
 
Condition of approval:
PACKER SET JUST ABOVE TOP LINER, AS CLOSE AS POSSIBLE TO TOP PERF-OK.
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE800
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE800
No channel test.