Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06158UNION PACIFIC
41-20
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
7/1/2023
RANGELY
72370
RIO BLANCO  103
SENE 20 2N102W 6
314583View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:6/23/2009MIT Assigned By:KOEHLER, BOB
Date Recv'd:6/24/2009Facility ID: 150200
DocNum:1769453Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameUNION PACIFIC
Operator contact:DIANE L  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:TUBING/PACKER LEAK
Repair Desc:Clean out, fish packers, replace tubing with 187 jts 2 7/8" FL DYB
Test Date:6/22/2009
Field Rep:
Approved Date:6/29/2009
Approved by:KOEHLER, BOB
Last Approved MIT:5/9/2007
Injection/Producing Formation Zones:WEBR
Perforation Interval:6122-6625
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6045
Top Packer Depth:5452
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE
5 MIN CASE
CASE BEFORE
FINAL CASE790
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-10
START CASE800
No channel test.