Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06236FEE
18
SCOUT ENERGY MANAGEMENT LLC
10779
AC
5/1/2023
RANGELY
72370
RIO BLANCO  103
SESE 29 2N102W 6
414661View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:9/24/2014MIT Assigned By:Browning, Chuck
Date Recv'd:9/29/2014Facility ID: 150200
DocNum:1171725Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON USA INC
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameFEE
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:9/24/2014
Field Rep:Browning, Chuck
Approved Date:8/19/2016
Approved by:Browning, Chuck
Last Approved MIT:8/18/2014
Injection/Producing Formation Zones:WEBR
Perforation Interval:
Open Hole Interval:5626-6386
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:5782
Top Packer Depth:5506
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1115
5 MIN CASE1120
FINAL CASE1111
FINAL TUBE1824
INITIAL TUBE1824
LOSS OR GAIN-23
START CASE1134
No channel test.