Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-09141MCLAUGHLIN, A C
76X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
2/1/2024
RANGELY
72370
RIO BLANCO  103
SENW 14 2N103W 6
315733View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/18/2014MIT Assigned By:Browning, Chuck
Date Recv'd:8/19/2014Facility ID: 150200
DocNum:1171683Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameMCLAUGHLIN, A C
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:8/18/2014
Field Rep:Browning, Chuck
Approved Date:8/18/2014
Approved by:Browning, Chuck
Last Approved MIT:4/12/2010
Injection/Producing Formation Zones:WEBR
Perforation Interval:6369-6760
Open Hole Interval:NA
Bridge/Cement Plug Depth:NA
Tubing Size:2.875
Tubing Depth:6246.1
Top Packer Depth:6160.3
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1235
5 MIN CASE1235
CASE BEFORE0
FINAL CASE1235
FINAL TUBE1473
INITIAL TUBE1473
LOSS OR GAIN0
START CASE1235
No channel test.