Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-60003W. P. MELLEN
1
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
11/9/2022
RANGELY
72370
RIO BLANCO  103
SENE 16 2N103W 6
316724View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/27/2012MIT Assigned By:BROWNING, CHUCK
Date Recv'd:8/28/2012Facility ID: 150200
DocNum:1171407Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameW. P. MELLEN
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:8/27/2012
Field Rep:BROWNING, CHUCK
Approved Date:8/27/2012
Approved by:BROWNING, CHUCK
Last Approved MIT:8/4/2004
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6688-7361
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6538
Top Packer Depth:6453
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1200
5 MIN CASE1200
CASE BEFORE0
FINAL CASE1200
FINAL TUBE
INITIAL TUBE
LOSS OR GAIN0
START CASE1200
No channel test.