Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06158UNION PACIFIC
41-20
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
7/1/2023
RANGELY
72370
RIO BLANCO  103
SENE 20 2N102W 6
314583View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:8/8/2012MIT Assigned By:BROWNING, CHUCK
Date Recv'd:8/15/2012Facility ID: 150200
DocNum:1171398Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameUNION PACIFIC
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:CASING LEAK
Repair Desc:CASING REPAIR. FORM5 SUBMITTED ONLINE-DOC#40313866
Test Date:7/17/2012
Field Rep:BROWNING, CHUCK
Approved Date:8/13/2012
Approved by:BROWNING, CHUCK
Last Approved MIT:6/22/2009
Injection/Producing Formation Zones:WEBR
Perforation Interval:6122-6625
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6044.6
Top Packer Depth:5780.6
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE1200
5 MIN CASE1200
CASE BEFORE0
FINAL CASE1200
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE1200
No channel test.