Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06194LEVISON
13
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
3/1/2024
RANGELY
72370
RIO BLANCO  103
NWNW 26 2N102W 6
314600View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:7/22/2009MIT Assigned By:KRABACHER, JAY
Date Recv'd:7/24/2009Facility ID: 150200
DocNum:1171079Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON U S A INC
Address:6001 BOLLINGER CANYON RD  SAN RAMON  CA 94583
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameLEVISON
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:plug set in profile, perf. tubing, circ. packer fluid, re-tested casing integrity. verifies that well has tubing leak, (not casing) will remain shut-in and on work-schedule to have tubing replaced
Test Date:7/14/2009
Field Rep:
Approved Date:7/24/2009
Approved by:KRABACHER, JAY
Last Approved MIT:5/3/2004
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6172 - 6785
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6422
Top Packer Depth:6047
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE810
5 MIN CASE825
CASE BEFORE0
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-40
START CASE840
No channel test.