Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-10726A.C.MCLAUGHLIN
91X
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
4/26/2023
RANGELY
72370
RIO BLANCO  103
SWSW 11 2N103W 6
316528View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/3/2007MIT Assigned By:KRABACHER, JAY
Date Recv'd:10/5/2007Facility ID: 150200
DocNum:1171015Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameA.C.MCLAUGHLIN
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:9/8/2007
Field Rep:
Approved Date:10/5/2007
Approved by:KRABACHER, JAY
Last Approved MIT:9/23/2006
Injection/Producing Formation Zones:WEBR
Perforation Interval:6494 - 6705
Open Hole Interval:NA
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6506
Top Packer Depth:6418
Multiple Packers:N
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE810
5 MIN CASE810
CASE BEFORE0
FINAL CASE810
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE810
No channel test.