Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06330HAGOOD M C
A-3
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
5/18/2022
RANGELY
72370
RIO BLANCO  103
NWNE 15 2N103W 6
314678View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:5/15/2007MIT Assigned By:KRABACHER, JAY
Date Recv'd:5/29/2007Facility ID: 150200
DocNum:1170961Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameHAGOOD M C
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:5-YEAR UIC TEST
Test Date:5/8/2007
Field Rep:KRABACHER, JAY
Approved Date:5/29/2007
Approved by:KRABACHER, JAY
Last Approved MIT:4/25/2002
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:6448 - 6539
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6444
Top Packer Depth:6331
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE810
CASE BEFORE0
FINAL CASE795
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN-25
START CASE820
No channel test.