Skip to Main Content

Incident Search

COGIS - Mechanical Integrity Test Report
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation IDRelated Facilities
WELL05-103-06250EMERALD
40
SCOUT ENERGY MANAGEMENT LLC
10779
IJ
9/18/2019
RANGELY
72370
RIO BLANCO  103
SENW 31 2N102W 6
314632View Related Related
 
Form 21View Related Related View DocsDoc
Date Submitted:10/20/2006MIT Assigned By:KRABACHER, JAY
Date Recv'd:10/23/2006Facility ID: 150200
DocNum:1170890Facility Status:AC
Operator Information:
Oper. No.16700
Operator:CHEVRON PRODUCTION COMPANY
Address:100 CHEVRON RD  RANGELY  CO 81648
Type Of Facility:UIC ENHANCED RECOVERYWell Status: AC
Facility NameEMERALD
Operator contact:DIANE  PETERSON
Location:  qtrqtr: SENE section: 16 township: 2N range: 103W meridian: 6
MIT Details:
Test Type:VERIFICATION OF REPAIRS
Repair Type:OTHER
Repair Desc:set tubing plug. circ. packer fluid
Test Date:10/16/2006
Field Rep:
Approved Date:10/23/2006
Approved by:KRABACHER, JAY
Last Approved MIT:5/4/2004
Injection/Producing Formation Zones:WEBR
Perforation Interval:NA
Open Hole Interval:5714 - 6336
Bridge/Cement Plug Depth:
Tubing Size:2.875
Tubing Depth:6260
Top Packer Depth:5608
Multiple Packers:Y
 
Condition of approval:
Test Data:Wellbore Channel Test:
Reading TypePressure
10 MIN CASE800
5 MIN CASE800
CASE BEFORE0
FINAL CASE800
FINAL TUBE0
INITIAL TUBE0
LOSS OR GAIN0
START CASE800
No channel test.